ML17313A170

From kanterella
Jump to navigation Jump to search
Forwards PVNGS Unit 2 ISI Rept,Seventh Refueling Outage
ML17313A170
Person / Time
Site: Palo Verde Arizona Public Service icon.png
Issue date: 01/08/1998
From: Ide W
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML17313A171 List:
References
102-04058-WEI-A, 102-4058-WEI-A, NUDOCS 9801140086
Download: ML17313A170 (4)


Text

CATZaoar 1

R ULAx Y INFORMAT1ON DISTRIBUTI SYSTEM (RIDS)

'ACCESSION NBR:9801140086 DOC.DATE: 98/01/08 NOTARIZED: NO DOCKET FACIL:STN-50-529 Palo Verde Nuclear Station, Unit 2, Arizona'Publi 05000529 AUTH.NAME AUTHOR AFFILIATION IDE,W.E.

Arizona Public Service Co.

(formerly Arizona Nuclear Power RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Forwards "PVNGS Unit 2 ISI Rept, Seventh Refueling Outage."

DISTRIBUTION CODE: A047D COPIES RECEIVED:LTR ENCL SIZE:

C TITLE: OR Submittal: Inservice/Testing/Relief from ASM Code -

L-89-04 NOTES:Standardized plant.

05000529 p RECIPIENT ID CODE/NAME PD4-2 LA CLIFFORD,J COPIES LTTR ENCL 1

1 1

1 RECIPIENT ID CODE/NAME PD4-2 PD COPIES LTTR ENCL 1

1 0

INTERNAL: A LE NTER NUDOCS-RES/DET/EIB CT 1

1 1

1 1

1 1

1 AEOD/SPD/RAB NRR/DE/EMEB OGC/HDS2 RES/DET/EMMEB 1

1 1

1 1

0 1

1 EXTERNAL: LITCO ANDERSON NRC PDR 1

1 1

1 NOAC 1

1 D

0 NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD)

ON EXTENSION 415-2083 TOTAL NUMBER OF COPIES REQUIRED:

LTTR 14 ENCL 13

f

'e

Commitment. Inenstlan, &eryy.

Palo Verde Nuclear Generating Station WilliamE. Ide Vice President Nuclear Engineering TEL 602/3936116 FAX 602/393-6077 Mail Station 7605 P.O. Box 52034 Phoenix, AZ 65072-2034 102-04058 WEI/AKK/CJ J January 8, 1998 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Station P1-37 Washington, DC 20555-0001

Dear Sirs:

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Unit 2 Docket No. STN 50-529 Inservice Inspection Report Seventh Refueling Outage Pursuant to 10 CFR 50.55a, enclosed please find the PVNGS Unit 2 Inservice Inspection Report for the seventh refueling outage.

Should you have any questions, please contact Scott A. Bauer at (602) 393-5978.

Sincerely, WEI/AKK/CJ J Enclosure cc:

E. W. Merschoff K. E. Perkins J. W. Clifford J. H. Moorman 980ii40086 980i08 I DR ADGCX OSOOOSae

,/,/

8 PDR lllllllllllllllllllll!ill llllIIllllI

0 A