~p,R REgy P0 Cy nO lh

': e 0

0

+a*++

t UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 2~001 July 29, 1997 js9~'15~A Hr. James H. Levine Executive Vice President, Nuclear Arizona Public Service Company Post Office Box 53999

Phoenix, Arizona 85072-3999

SUBJECT:

REQUEST FOR EXEHPTION FROH THE REQUIREHENTS OF 10 CFR 70.24 FOR THE PALO VERDE NUCLEAR GENERATING STATION (TAC NOS.

H98280, H98281,'98282)

Dear Hr. Levine:

By letter dated Harch 28,

1997, you requested an exemption from the requirements of 10 CFR 70.24.

The staff is currently reviewing your request.

To assist the staff in its review, please supplement your initial request with a letter under oath or affirmation addressing the following seven criteria for granting exemptions from this rule.

For each criterion that you do not meet, pl'ease explain why meeting that criterion is not necessary in the case of the Palo Verde Station.

1.

Plant procedures do not permit more than one pressurized-water reactor or three boiling-water reactor fuel assemblies to be out of an approved storage configuration at one time.

2.

The k-effective of the fresh fuel storage racks filled with fuel of the maximum permissible U-235 enrichment and flooded with pure water does not exceed 0.95, at a 95 percent probability, 95 percent confidence level.

3.

If optimum moderation of fuel in the fresh fuel storage racks occurs when the fresh fuel storage racks are filled with low-density hydrogenous fluid, the k-effective corresponding to this optimum moderation does not exceed 0.98, at a 95 percent probability, 95 percent confidence level.

4.

The k-effective of spent fuel storage racks filled with fuel of the maximum permissible U-235 enrichment and flooded with pure water does not exceed 0.95, at a 95-percent probability, 95-percent confidence level.

5.

The quantity of SNH other than nuclear fuel stored on site in any given area is less than the quantity necessary for a critical mass.

6.

Radiation monitors, as required by GDC 63, are provided in fuel storage and handling areas to detect excessive radiation levels and to initiate appropriate safety actions.

l gf007~s

@fan] o 97073%0153 970729 PDR ADOCK 05000528 P

PDR

P 4/

g t

Hr. James H. Levine I 2 July 29, 1997 7.

The maximum nominal U-235 enr'ichment does not exceed 5 wtX.

If you have any questions, please contact me at (301) 415-1362.

Sincerely, Original Signed By Kristine M. Thomas, Project Manager Project Directorate IV-2 Division of Reactor Projects - III/IV Office of Nuclear Reactor Regulation Docket Nos.

STN 50-528, STN 50-529 DISTRIBUTION:

and STN 50-530 (Docket Fil e3 PUBLIC cc:

See next page PDIV-2 Reading JRoe EAdensam WBateman KThomas

'Peyton ACRS,'WFN

OGC, 015B18
KPerkins, RIV/WCFO
PGwynn, RIV
DKirsch, WCFO JLyons DOCUMENT NAME: PV98280.RAI
  • See Previous Concurrence OFC NAME DATE SRXB:BC*

PDIV-2 PH PDIV-2 LA KT omas:ye 7

97 EPey n

7

/97 JLyons 7 25 97 OFFICIAL RECORD COPY=

Hr.. James M. Levine

~+4, July 29, f997 CC:

Mr. Steve Olea Arizona Corporation Commission 1200 W. Washington Street

Phoenix, Arizona 85007 Douglas Kent Porter Senior Counsel Southern California Edison Company Law Department, Generation Resources P.O.

Box 800

Rosemead, California 91770 Senior Resident Inspector USNRC P. 0.

Box 40 Buckeye, Arizona 85326 Regional Administrator, Region IV U. S. Nuclear Regulatory Commission Harris Tower 8 Pavillion 611 Ryan Plaza Drive, Suite 400 Arlington, Texas 76011-8064

Chairman, Board of Supervisors ATTN:

Chairman 301 W. Jefferson, 10th Floor Phoenix, Arizona 85003 Hr. Aubrey V. Godwin, Director Arizona Radiation Regulatory Agency 4814 South 40 Street

Phoenix, Arizona 85040 Hs. Angela K. Krainik, Manager Nuclear Licensing Arizona Public Service Company P.O.

Box 52034

Phoenix, Arizona 85072-2034 Hr. John C. Horne, Vice President Power Supply Palo Verde Services 2025 N. Third Street, Suite 220 Phoenix, Arizona 85004 Hr. Robert Burt Los Angeles Department of Water 5

Power Southern California Public Power Authority 111 North Hope Street, Room 1255-B Los Angeles, California 90051 Hr. David Summers Public Service Company of New Hexico 414 Silver SW, ¹0604 Albuquerque, New Mexico 87102 Hr. Robert D. Bledsoe Southern California Edison Company 14300 Mesa Road, Drop D41-SONGS San Clemente, California 92672 Hr. Robert Henry Salt River Project 6504 East Thomas Road Scottsdale, Arizona 85251 Terry Bassham, Esq.

General Counsel El Paso Electric Company 123 W. Hills El Paso, Texas 79901

I