CA.J:KUUKX J.

REGULAT INFORMATION DISTRIBUTIONSTEM (RZDS)

ACCESSION NBR:9603290165 DOC.DATE:~~1 NOTARIZED: NO DOCKET FACIL:STN-50-528 Palo Verde Nuclear Station, Unit 1, Arizona Publi 05000528 STN-50-529 Palo Verde Nuclear Station, Unit 2, Arizona Publi 05000529 STN-50-530 Palo Verde Nuclear Station, Unit 3, Arizona Publi 05000530 AUTH.NAME AUTHOR AFFILIATION KRAINIK,A.K.

Arizona Public Service Co. (formerly Arizona Nuclear Power RECIP.NAME RECIPIENT AFFILIATION

SUBJECT:

"Personnel Monitoring Rept for 1995 for PVNGS."

ltr.

DISTRIBUTION CODE:

ZE56D COPIES RECEIVED:LTR 2 ENCL TITLE: 20.407 Annual Personnel Monitoring Rpt/Annual Rad NOTES:STANDARDIZED PLANT Standardized plant.

Standardized plant.

C W/~60320 A

SIZE:

T Exposure Rpt by Fun E

05000528 05000529 G

05000530 0 RECIPIENT ID CODE/NAME PD4-2 PD INTERNAL: ACNW NMSS/SCDB/SSSS RES/RPHEB EXTERNAL: LITCO BRYCE,J H

NRC PDR COPIES LTTR ENCL 1

0 6

6 1

1 1

1 1

1 1

1 RECIPIENT ID CODE/NAME THOMASFC NRR/DRPM/PERB/B RGN4 01 NOAC COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

. 1 D

0 E

N NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTETH CONTACT THE DOCUMENT CONTROL DESKS ROOM OWFN SD-5(EXT. 415-2083)

TO ELIMINATE YOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 16 ENCL 15

'l

Arizona Public Service Company PALO VERDE NUCLEAR GENERATING STATION P.O. BOX 52034

~

PHOENIX, ARIZONA85072-2034 102-03630-AKK/P MB March 20, 1996 REIRS Project Manager Office of Nuclear Regulatory Research U. S. Nuclear Regulatory Commission Washington, DC 20555

Dear Sir:

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Units',2, and 3 Docket Nos. STN 50-528/529/530 Personnel Monitoring Report for 1995 Enclosed please find a copy of the Personnel Monitoring Report for 1995 which is submitted pursuant to PVNGS Technical Specification 6.9.1.5.

Ifyou have any questions, please contact Scott A. Bauer at (602) 393-5978.

Sincerel, Angela K Krainik, Department Leader Nuclear Regulatory Affairs AKK/PMB/pb Enclosure cc:

Document Control Desk (Original)

L. J. Callan K E. Johnston K E. Perkins C. R. Thomas r ~nf;PQ y, O5000528 i65 95i23i PDR ADOC R

ENCLOSURE PERSONNEL MONITORINGREPORT FOR 1995 FOR PALO VERDE NUCLEARGENERATING STATION

0

PAGE:

1 APS/PVNGS RADIOLOGICAL RECORDS

& ACCESS CONTROL SYSTEM NRC REQ GUIDE 1 ~ 16 REPORT (POR THE YEAR 1995)

DATE: 02/27/96 TIME: 14:27:27 Arizona Public Service Co.

P.O.

Box 52034

Phoenix, AZ 85072-2034 Palo Verde Nuclear Generation Station NRC-License No.

NPP-41 NPP-51 NPP-74 Number of Personnel

>> 100mR) otal Man-Rem Work & J'ob Punction REACTOR OPERATIONS

& SURVEILLANCE Maintenance Personnel Operating Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel ROUTINE MAINTENANCE Maintenance Personnel Operating Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel ZNSERVZCE INSPECTION Maintenance Personnel Operating Pezsonnel Health Physics Personnel Supervisozy Personnel Engineering Personnel SPECIAL MAINTENANCE Maintenance Personnel Operating Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel WASTE PROCESSZNQ Maintenance Personnel Operating Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel REPUELING Maintenance Personnel Operating Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel TOTAL Maintenance Personnel Operating Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel GRAND TOTAL Station Employees 16 37 55 6

6 175 35 56 25 25 1

0 10 0

0 42 4

5 11 4

235 77 126 43 37 518 Utility Employees Contract Workers 26 0

59 0

1 390 5

86 3

29 26 1

0 0

4 34 0

0 1

3 26 0

12 0

7 503 7

165 4

44 723 Station Employees

5. 962 12.569
14. 015 2 ~ 375 3.270 76.694 15 ~ 497 20.761 8.975
15. 803 0.325 0.320 0.027 0.125 0.654
0. 177
0. 070 0.125 0.000 0.308 0.366 0.075 3.936
0. 156 0.003
17. 818
1. 005
1. 921 3.698 1.384 101. 342 29.536 40.785
15. 329 21.422 208.414 Utility Employees 0.000 0.000 0.000 F 000 0.000 0.000 0.000 F 000 0.000 F 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Contract Workers 7.454 0.132
16. 633 0.044 0.606 168.978 1.320 28 '79 0 '56 9.996 9.267 0.549 0 '04 0.000 2.880
12. 975 0.000 0.480 0.662 0.510 1.160 0.444 4.030 0.050
0. 144 9.252 0.020 4.447 0.000 1.839 209.086 2.465 54.573 1.712
15. 975 283. 811 Total Record Whole Body for the Year 1995:

SID = 492.225 Rem TLO = 4B1.593 Rem

1 I