<PS RECII+
+
~
UNITEDSTATES
NUCLEAR REGULATORY COMMISSION
REGION IV
611 RYAN PLAZA DRIVE, SUITE 400
FEB I6 less
Arizona Public Service
Company
ATTN:
William L. Stewart
Executive Vice President,
Nuclear
P.O.
Box 53999
Phoenix.
85072-3999
SUBJECT:
NRC INSPECTION
REPORT 50-528/95-23:
50-529/95-23;
50-530/95-23
This refers to the inspection
conducted
by Messrs.
C. Hyers
and
H. Runyan of
this office on December
11-15
~
1995.
and January
8-12,
1996,
a't the Palo Verde
Nuclear
Generating Station
~ Units 1,
2,
and 3, facility.
The purpose of the
inspection
was to determine whether activities authorized
by the license were
conducted safely and in accordance
with NRC requirements.
At the conclusion
of the inspection,
the findings were discussed
with those
members of your
'taff identified in the enclosed
report.
Areas examined during the inspection are identified in the report.
The
inspection evaluated
the effectiveness
of your activities to ensure the
operability
and reliability of motor operated
valves in safety-related
systems
and to meet your commitments to Generic Letter 89-10 'Safety-Related
Motor-Operated
Valve Testing
and Surveillance."
Within these
areas,
the
inspection consisted of selective examinations of procedures
and
representative
records,
interviews with personnel.
and observation of
activities in progress.
The results of this inspection are summarized in the
enclosed
report.
Our inspectors
generally concluded that you had adequately
completed your
initial motor -operated
valve test activities.
However our veritication of
your efforts to complete Generic Letter 89-10 is contingent
upon you
providing. for NRC review, additional information and justification for
certain parts of the program.
Specifically you need to provide information
concerning your grouping of untested
motor-operated
valves,
the valve factor's
used in those groups'our
trending activities,
and the status of the open
findings from your recently completed self-assessment
of your motor-operated
valve program.
Your written response
to the items identified in Section
1 of
the enclosed
report is requested within 60 days of your
r eceipt of this
letter.
In accordance
with 10 CFR 2.790 of the NRC's "Rules of Practice,"
a copy
of'his
letter
and its enclosures will be placed in the
NRC Public Document
Room.
9602220137
960216
ADQCK 05000528
8
0
Arizona Public Service
Company
-2-
Should you have any questions
concerning this inspection,
we will be pleased
to discuss
them with you.
Sincer
y,
Dockets:
50-528
50-529
50-530
Licenses:
NPF-51
homas
P.
Gwynn, ir tor
Division of React
afety
Enclosure:
NRC Inspection
Report
50-528/95-23:
50-529/95-23;
50-530/95-23
w/attachment
cc w/enclosure:
Arizona Corporation
Commission
ATTN:
Hr. Steve Olea
1200
W. Washington Street
Phoenix,
85007
Southern California Edison
Company
ATM:
T.
E. Oubre,
Esq.
P.O.
Box 800
Rosemead.
Cali fornia
91770
Arizona Radiation Regulatory Agency
ATIN:
Aubrey V. Godwin, Director
4814 South 40 Street
Phoenix.
85040
Naricopa
County Board of Supervisors
ATIN:
Chairman
ill South Third Avenue
Phoenix,
85003
1
l
8
0
Arizona Public Service
Company
Palo Verde Services
ATTN:
Curtis Hoskins,
Executive
Vice President
and
Chi ef Operating Officer
2025
N. 3rd Street,
Suite 220
Phoenix,
85004
Akin, Gump. Strauss,
Hauer
and Feld
El Paso Electric Company
ATTN:
Roy P.
Lessey, Jr.,
Esq.
1333
New Hampshire Avenue, Suite 400
D'.C.
20036
Arizona Public Service
Company
ATTN:
Angela
K. Krainik, Manager
Nuclear Licensing
P.O.
Box 52034
Phoenix,
85072-2034
f
1
'
Arizona Public Service
Company
E-Mail report to D. Nelson
(DJN)
E-Mail report to
NRR Event Tracking System
(IPAS)
bcc to
DMB (IE01)
bcc distrib.
by RIV:
L. J. Callan
DRS-PSB
Branch Chief (DRP/F,
WCFO)
Senior project Inspector
(DRP/F,
WCFO)
Leah Tremper
(OC/LFDCB.
MS:
TWFN 9E10)
T. Scarbrough
(NRR)
E. Kelly (RI)
Resident
Inspector
MIS System
RIV File
Branch Chief (DRP/TSS)
M.
Hammond
(PAO.
WCFO)
J.
Jacobson
(RIII/DRS)
P. Frederickson
(RII)
g ~CP
DOCUMENT NAME:
R:K PVNPV523rp.CJM
To receive copy of document, indicate In box: "C" =
y without enctosure
"E""-py with enclosures "N" ~ No copy
RIV:RI: EB
RI:EB
C:EB
EMEB:NR
D:DRS
F:DRP
D:DRS
FRunyan
CJMyer
VanDenburgh
RWessma
TPGwyn
DKirsch
TPGwynn
Y
02/(
/96
02/I /9
02/
/96
02/07/96
02/
6
02/
96
2/
/9
210139
I
0
Arizona Public Service
Company
I'4-
E-Mail report to D. Nelson
(DJN)
E-Mail report to NRR Event Tracking System
(IPAS)
bcc to
DMB ( IEOl)
bcc distrib. by RIV:
L. J. Callan
DRS-PSB
Branch Chief (DRP/F,
WCFO)
Senior Project Inspector
(DRP/F,
WCFO)
Leah Tremper
(OC/LFDCB,
MS:
IWFN 9E10)
T. Scarbrough
(NRR)
E. Kelly (RI)
Resident
Inspector
MIS System
RIV File
Branch Chief (DRP/TSS)
M.
Hammond
(PAO,
WCFO)
J.
Jacobson
(RIII/DRS)
P. Frederickson
(RII)
g p)g,c
f'OCUMENT
NAME:
R:t PV'iPV523rp.CJM
To receive copy of document, indicate in box: "C" = Q
y without enctosure
"E" =
py with enctosures "N" = No copy
RIV:RI: EB
RI:EB
!':EB
EMEB:NR
D:DRS
F:DRP
D:DRS
FRunyan
CJMyer
VanDenburgh
RWessma
TPGwyn
DKirsch
TPGwynn
Y
02/(2,/96
02/( /9
02/
/96
02/07/96
02/
6
02/
96
2/
/9