PR.IC)R.I EY'ACCELE RATED RlDS P ROC ESSIX REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
+Zoo ACCESSION NBR:9503070284 DOC.DATE: 95/02/28 NOTARIZED:
NO DOCKET FACIL:STN-50-529 Palo Verde Nuclear Station, Unit 2, Arizona Publi 05000529 AUTH.NAME AUTHOR AFFILIATION STEWART,W.L.
Arizona Public Service Co.
(formerly Arizona Nuclear Power RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)
SUBJECT:
Forwards "PVNGS Unit 2 SG Eddy Current Exam U2M5 Midcycle Outage."
Generators inspected in Jan 1994,usincI eddy current testing technology comprised of both bobbin coal probe 6
motorized rotating pancake coil probe.
DISTRIBUTION CODE:
A001D COPIES RECEIVED:LTR ENCL SIZE:
TITLE: OR Submittal:
General Distribution NOTES:Standardized plant.
05000529 RECIPIENT ID CODE/NAME PD4-2 LA HOLIAN, B INTERNAL: ACRS NRR/DRCH/HICB NRR/DSSA/SRXB OGC/HDS2 EXTERNAL: NOAC COPIES LTTR ENCL 1
1 1
1 6
6 1
1 1
1 1
0 1
1 RECIPIENT ID CODE/NAME PD4-2 PD TRAN, L NRR/DSSA/SPLB NUDOCS-ABSTRACT NRC PDR COPIES LTTR ENCL 1
1 1
1 1
1 1
1 1
1 1
1 NOTE TO ALL"RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE iVASTE!CONTACTTHE DOCUMENTCONTROL DESK, ROOM Pl-37 (EXT. 504-2083 ) TO ELliiIIVATEYOUR NAME PRO'i!
DISTRIBUTIONLISTS I'OR DOCl;MENTS YOU DON"I'EED!
I TOTAL NUMBER OF COPIES REQUIRED:
LTTR 18 ENCL 17
1L 1
Arizona Public Service Company P.O. BOX 53999
~
PHOENIX. ARIZONA85072-3999 WILLIAML. STEWART EXECUTIVEVICEPRESIDENT NUCLEAR February 28, 1995 001-00707-WLS U.S. Nuclear Regulatory Commission ATIN: Document Control Desk Mail Station P1-37 Washington, DC 20555-0001
Reference:
Letter 102-02852, dated March 8, 1994, from W.F.Conway, Executive Vice President Nuclear, APS, to USNRC
Dear Sirs:
Subject:
Palo Verde Nuclear Generating Station (PVNGS)
Unit 2 Docket No. STN 50-529 Steam Generator Eddy Current Examination-Midcycle Outage (U2M5)
File: 95-056-026 ln accordance with Technical Specification 4.4.4.5b, attached please find the Unit2 Steam Generator Eddy Current Examination Report-Midcycle Outage (U2M5) ~ The Unit 2 steam generators were inspected in January 1994, using eddy current testing technology comprised of both bobbin coil probe and motorized rotating pancake coil probe. The inspection identified a total of 330 tubes as having axial indications, 22 in steam generator 2-1 and 308 in steam generator 2-2. Four tubes having circumferential indications were also identified in steam generator 2-2 at the hotleg tubesheet.
This information was previously transmitted to the staff by the referenced letter.
Should you have any questions, please call Scott A. Bauer at (602) 393-5978.
Sincerely, WLS/SAB/JRP/rv Attachment CC:
L. J. Callan K. E. Perkins K. E. Johnston B. E. Holian I.
Barn es P70l33 9503070284 950228 PDR ADOCK 05000529
> -I.
CI,
t J
j I
.1