ML17311A338

From kanterella
Jump to navigation Jump to search
Forwards Topical Rept, Analysis of 137 Degree Capsule from APS Palo Verde Unit 1 Reactor Vessel Radiation Surveillance Program
ML17311A338
Person / Time
Site: Palo Verde 
Issue date: 10/11/1994
From: Stewart W
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML17311A339 List:
References
102-03145-WLS-S, 102-3145-WLS-S, NUDOCS 9410180156
Download: ML17311A338 (7)


Text

p A.1CDR.IMY' CELERATED RIDS PROCESSING)

REGULATORY XNFORMATION DXSTRXBUTXON SYSTEM (RIDS)

ACCESSION NBR:9410180156 DOC.DATE: 94/10/11 NOTARIZED: NO DOCKET FACIL:STN-50-528 Palo Verde Nuclear Station, Unit 1, Arizona Publi 05000528 AUTH.NAME AUTHOR AFFILXATION STEWART,W.L.

Arizona Public Service Co.

(formerly Arizona Nuclear Power p

RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

R

SUBJECT:

Forwards Topical Rept, "Analysis of 137 Degree Capsule From APS Palo Verde Unit 1 Reactor Vessel Radiation Surveillance Program."

DISTRIBUTION CODE:

AOOID COPIES RECEIVED:LTR )

ENCL g SIZE: +fl g g TITLE: OR Submittal: General Distribution NOTES:STANDARDIZED PLANT 05000528 0

RECIPIENT ID CODE/NAME PD4-2 LA HOLIAN, B I:NTERNAL: ACRS NRR/DE/EELB NRR/DRPW NRR/DSSA/SRXB OGC/HDS2 XTERNAL: NOAC COPIES LTTR ENCL 1

1 1

1 6

6 1

1 1

1 1

1 1

0 1

1 RECIPIENT ID CODE/NAME PD4-2 PD TRAN,L AXLE=CENTER 0

NRR/DRCH/HICB NRR/DSSA/SPLB NUDOCS-ABSTRACT NRC PDR COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 1

1 1

1 D

0 U

NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE iVASTE!CONTACTTHE DOC! 'MENTCONTROL DESK, ROOhi PI-37 (EXT. 504-2083 ) TO EL!XI!NATEYOUR FAME PRO%I DISTRIBUTIONLISTS I'OR DOCUMENTS YOU DON"I'LED!

TOTAL NUMBER OF COPXES REQUIRED:

LTTR 20 ENCL 19

Arizona Public Service Company P.O. BOX 53999

~

PHOENIX, ARIZONA85072<999 WILLIAML. STEWART EXECIJTIVEVICEPRESIDENT NUCLEAR 102-03145-WLS/SAB/JRP October 11, 1994 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Station P1-37 Washington, DC 20555

Dear Sirs:

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Unit 1 Docket No. STN 50-528 Reactor Vessel Material Surveillance Capsule File: 94-056-026 Pursuant to 10 CFR 50, Appendix H, this letter transmits a report of the analysis of a PVNGS Unit 1 reactor vessel material surveillance capsule.

The report presents the results of the examination of the Unit 1 surveillance capsule removed from the 13T location. This is the first capsule to be removed from the reactor in accordance with the

'reactor vessel material surveillance program which monitors the effects of neutron irradiation on the Unit 1 reactor pressure vessel material. The 13T capsule was removed from the reactor vessel during the Unit 1 refueling outage (October'9, 1993), after 4.53 effective full power years (EFPY) of plant operation (exposure).

Westinghouse Science and Technology Center Hot Cell Facility performed the post irradiation mechanical testing of the Charpy V-notch impact, tensile and precracked Charpy V-notch surveillance specimens.,

The removal of the capsule is in accordance with Unit

1. Technical Specification surveillance requirement 4.4.8.1.2, Table 4.4-5, which lists capsule number 3, vessel location 13T, as having a withdrawal time of between 4 and 5 EFPY.

n PI>P 9410180156 941011

'DR ADGCK 05000528 P

PDR

la

U. S. Regulatory Commission ATTN: Document Control Desk Reactor Vessel Material Surveillance Capsule Page 2 The surveillance results presented in the enclosed report do not change the value of RTpyg calculated for Palo Verde.

Should you have any questions, please contact Scott A. Bauer at (602) 393-5978.

Sincerely, WLS/SAB/JRP/Iv Enclosure cc:

L. J. Cailan K. E. Perkins B. E. Holian K. E. Johnston

ENCLOSURE ANALYSISOF THE 137'APSULE FROM THE ARIZONA PUBLIC SERVICE COMPANY PALO VERDE - UNIT 1 REACTOR VESSEL RADIATIONSURVEILLANCE PROGRAM

~~0