Text
FORD I
REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:940
CIL:STN-50-528
STN-50-529
STN-50-530
AUTH.NAME
BEACHA,A.B.
RECIP.NAME
CONWAY,W.F.
5060068
DOC.DATE: 94/05/03
NOTARIZED:
NO
DOCKET
Palo Verde Nuclear Station, Unit 1, Arizona Publi
05000528
Palo Verde Nuclear Station, Unit 2', Arizona Publi
05000529
Palo Verde Nuclear Station, Unit 3, Arizona Publi'5000530
AUTHOR AFFILIATION
Region
4 (Post
820201)
RECIPIENT AFFILIATION
Arizona Public Service
Co. (formerly Arizona Nuclear
Power
Rl
p
/
05000528
05000529
05000530
0
NOTES:STANDARDZZED PLANT
Standardized
plant.
Standardized
plant.
SUBJECT:
Forwards insp repts
50-528/94-09,50-529/94-09
& 50-530/94-09
on 940215-0328.Several
areas
demonstrating
lack of thorough
engineering
evaluation
& followup of plant problems.
DISTRIBUTION CODE
IEOID
COPIES
RECEIVED LTR L ENCLl SIZE'
+ ~C)
TITLE: General
(50 Dkt)-Insp Rept/Notice of Violation Response
RECIPIENT
ID CODE/NAME
PDIV-3 PD
TRAN,L
I TERNAL: ACRS
AEOD/DSP/ROAB
AEOD/TTC
NRR/DORS/OEAB
NRR/DRIL/RPEB
NRR/PMAS/ILPBl
NUDOCS-ABSTRACT
OGC/HDS1
RES/HFB
EXTERNAL: EG&G/BRYCE,J.H.
COPIES
,LTTR ENCL
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
RECIPIENT
ID CODE/NAME
HOLIAN, B
AEOD/DEIB
AEOD/DSP/TPAB
DEDRO
NRR/DRCH/HHFB
NRR/DRSS/PEPB
NRR/PMAS/ILPB2
OE DIR
EG FILE
02
C3
FILE
01
NRC PDR
COPIES
LTTR ENCL
1
1
1
1
1
-1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
R
p
C
NOTE TO ALL RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK.
ROOhI P 1-37 (EXT. 504-2065) TO ELIMINATEYOUR NAh<E FROM DISTRIBUTION
LISTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES
REQUIRED:
LTTR
25
ENCL
25
,
I
l
I
UN IT E D STAT E6
NUCLEAR REGULATORY COMMISSION
REGION IV
611 RYAN PLAZA ORIVE, SUITE 400
ARLINGTON,TEXAS 76011 8064
MAY -3 IBM
Dockets:
50-528
50-529
50-530
Licenses:
NPF-51
Publ ic Ser vice Company
ATTN:
William F.
Conway
Executive Vice President,
Nuclear
P.O.
Box 53999
Phoenix,
85072-3999
SUBJECT:
NRC INSPECTION REPORT 50-528/94-09;
50-529/94-09;
50-530/94-09
This r efers to the inspection
conducted
by K. Johnston of this office, and the
inspectors identified in the enclosed
report
on February
15 through Narch 28,
1994.
The inspection
included
a review of activities authorized for your
Palo
Verde facility.
At the conclusion of the inspection,
the findings were
discussed
with those
members
of your staff identified in the enclosed report.
Areas
examined during the inspection
are identified in the report.
Within
these
areas,
the inspection consisted of selective
examinations of procedures
and representative
records,
interviews with personnel,
and observation of
activities, in progress.
This inspection identified several
areas
demonstrating
a lack of thorough
engineering evaluation
and followup of plant problems.
In one case,
a
4-year-old modification to essential
chiller instrumentation
was not reflected
in plant annunciator
response
procedures
and in the Final Safety Analysis
Report,
and your engineering staff still considered
the modification
temporary.
In another
case,
even though plant procedures
and personnel
recognized
the potential for a water
hammer event in Unit 1's
blowdown system during a manipulation- of the system's
containment isolation
valves,
on February
14,
1994, operators
caused
a water hamet
which damaged
a
pipe support
on this line.
The inspection
found that your engineering staff
had not fully evaluated
the impact of previous events
and
had not.followed
through
on
a modification to prevent the water
hammer.
We encourage
you to
review these
and the other examples
discussed
in the enclosed report
and to
determine
where the opportunities
were missed to correct these
problems.
-The inspection also found that the high intensity training for licensed
operators
was well implemented.
The program featured challenging scenarios,
in-depth critiques,
and management
involvement.
Operators
demo'nstrated
good
command
and control
and excellent communications.
We recognize that this
94050b00b8
940503
ADOCK 05000528
8
/g/l
'
l
J
Arizona Public Service
Company
effort demonstrates
considerable
management
commitment
and initiative and
anticipate its benefits in improved operations
performance.
The inspection identified one unresolved
item concerning the necessity of
declaring
a Notification of Unusual
Event during
a Unit 2 event where reactor
coolant system inventory inadvertently was drained to the refueling water
tank.
This matter is discussed
in Section 3.4 of the enclosed
inspection
report.
In accordance
with 10 CFR Part 2.790 of the NRC's "Rules of Practice,"
a copy
of this letter and its enclosures will be placed in the
NRC Public Document
Room.
Should you have
any questions
concerning this inspection,
we will be glad to
discuss
them with you.
Sincerely,
. Bill Beach, Director
Division of Reactor Projects
Encl osui es:
Appendix - NRC Inspection
Report
50-528/94-09;
50-529/94-09;
50-530/94-09
cc w/enclosures:
Arizona Corporation
Commission
ATTN:
Hr. Steve
Olea
1200
W. Washington Street
Phoenix,
85007
Southern California Edison
Company
ATTN:
James
A. Beoletto,. Esq.
P.O.
Box 800
Rosemead,
91770
ABB Combustion
Engineering Nuclear
Power
ATTN:
Charles
B. Brinkman,
Manager
Washington Nuclear Operations
12300 Twinbrook Parkway,
Suite
330
Rockville, Maryland
20852
Arizona Radiation Regulatory
Agency
ATTN:
Aubrey V. Godwin, Director
4814 South
40 .Street
Phoenix,
85040
I
Arizona Public Service
Company
~
~
~
Haricopa County Board of Supervisors
ATTN:
Chairman
111 South Third Avenue
Phoenix,
85003
Newman
8 Holtzinger,
P.C.
ATTN:
Jack
R.
Newman,
Esq.
1615
L Street,
N.W., Suite
1000
D.C.
20036
Palo Verde Services
ATTN:
Curtis Hoskins,
Executive
Vice President
and
Chief Operating Officer
2025
N. 3rd Street,
Suite
220
Phoenix, Arizona
85004
Akin, Gump, Strauss,
Hauer
and Feld
El
Paso Electric Company
ATTN:
Roy P.
Lessey, Jr.,
Esq.
1333
Avenue, Suite
400
D.C.
20036
Arizona Public Service
Company
ATTN:
Angela K. Krainik, Nanager
Nuclear Licensing
P.O.
Box 52034
Phoenix,
85072-2034
I
j
f
j
,
Arizona Public Service
Company
MAY -3 1994
E-Hail report to D. Sullivan
(DJS)
bcc to
DHB (IEOl)
bcc distrib.
by RIV:
L. J. Callan
DRSS-FIPB
Branch Chief (DRP/F)
RIV File
Leah Tremper,
OC/LFDCB, HS:
bcc w/o enclosure:
H. Smith,
WCFO
J. Bianchi,
WCFO
Resident
Inspector
HIS System
Senior Project Inspector
(DRP/F)
Branch Chief (DRP/TSS)
HNBB 4503
DRP F*
SRichards
RIV:SRI:DRP F*
KJohnston;df
4/22/94
4/18/94
prev>ous y concurre
C:DRP F*
HJWon
4/18/94
C:DRS*
DAcker
4/18/94
D:DRP
ABBeach
bISjse
f
I ll
Arizona Publ ic Service
Company
MAY -3 l994
E-Hail report to D. Sullivan
(DJS)
bcc to
DMB ( IE01)
bcc distrib.
by RIV:
L. J. Callan
DRSS-FIPB
Branch Chief (DRP/F)
RIV File
Leah Tremper,
OC/LFDCB, HS:
bcc w/o enclosure:
H. Smith,
WCFO
J. Bianchi,
WCFO
Resident
Inspector
HIS System
Senior. Project Inspector
(DRP/F)
Branch Chief (DRP/TSS)
HNBB 4503
0
4/22/94
4/18/94
previous y concurre
RIV:SRI:DRP F*
DRP F*
KJohnston;df
SRichards
C:DRP F*
HJWon
4/18/94
C:DRS*
DAcker
4/18/94
D:DRP
ABBeach
l
l