Advises NRC That Util Will Continue Updates on Progress of Insps of Unit 2 SGs & Will Inform NRC Upon Completion of Each Phase of Insp Plan,In Response to 930314 SG Tube Rupture Experienced at Unit 2
ML17310A301
Person / Time
Site: Palo Verde 
Issue date: 06/02/1993
From: Conway W
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
212-01016-WFC-R, 212-1016-WFC-R, NUDOCS 9306070046
Download: ML17310A301 (6)


Text

ACCEI ERAT DOCUMENT DIST UTION SYSTEM REGULA INFORMATZON DISTRZBUTIO YSTEM (RIDS)

~ci ACCESSION NBR:9306070046 DOC.DATE: 93/06/02 NOTARIZED: NO DOCKET N

FACIL:STN-50-529 Palo Verde Nuclear Station, Unit 2, Arizona Publi 05000529 AUTH.NAME AUTHOR AFFILIATION CONWAY,W.F.

Arizona Public Service Co. (formerly Arizona Nuclear Power RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Advises NRC that util will continue updates on progress of insps of Unit 2

SGs 6 will inform NRC upon completion of each phase of insp plan, in response to 930314 SG tube rupture experienced at Unit 2.

DISTRIBUTION CODE:

A001D COPIES RECEIVED:LTR ENCL SIZE:

TITLE: OR Submittal: General Distribution NOTES:Standardized plant.

05000529 RECIPIENT ID CODE/NAME PDV LA TRAMMELLiC INTERNAL: ACRS NRR/DORS/OTSB NRR/DSSA/SPLB NUDOCS-ABSTRACT OGC/HDS1 EXTERNAL: NRC PDR COPIES LTTR ENCL RECIPIENT ID CODE/NAME PDV PD TRANgL NRR/DE/EELB NRR/DRCH/HICB NRR/DSSA/SRXB O~~MB REG FILE 01 NSIC COPIES LTTR ENCL NOTE TO, ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTEl CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 504-2065) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEEDl TOTAL NUMBER OF COPIES REQUIRED:

LTTR 23 ENCL

0

Arizona Public Service Company P.O. BOX 53999

~

PHOENIX, ARIZONA85072<999 WILLIAMF. CONWAY EXECUTIVEVICEPRESIDENT NUCLEAR 212-01016-WFC/R JS June 2, 1993 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Station P1-37 Washington, DC 20555

Reference:

Letter 192-00837, dated April 13, 1993, from J. M. Levine, Vice President, Nuclear Production, APS to USNRC.

Dear Sirs:

Subject:

Palo Verde Nuclear Generating Station, Unit 2 Docket No. STN 50-529 Steam Generator Tube Rupture File: 93-056-026 On March 14, 1993, Palo Verde Nuclear Generating Station (PVNGS), Unit 2 experienced a steam generator tube rupture. The referenced letter transmitted Licensee Event Report 93-001-00 which describes the event.

Arizona Public Service Company (APS) formed a task force to perform a comprehensive root cause'f failure analysis and to develop an extensive inspection plan for both Unit 2 steam generators.

This task force is composed of APS personnel and other industry personnel with vast experience in steam generator technology. Since the March 14, 1993 tube rupture, there have been numerous discussions with the NRC regarding the status of the root cause analysis and the progress of the inspection plan.

The purpose of this letter is to advise the NRC that APS will continue its updates on the progress of the inspections of the Unit 2 steam generators and will inform the NRC upon completion of each phase of the inspection plan.

APS will also continue to update the NRC regarding actions being taken to determine the root cause of the tube rupture, as well as observed tube degradation, and will meet with the NRC as necessary to discuss these actions and the results.

0300'58

'TI306070046, 930602 PDR ADOCN'5000529 8

PDR yP I p

0

~g

.n I

~

~

h,'

1 t

I I

N4 5

U. S. Nuclear Regulatory Commission ATIN: Document Control Desk Steam Generator Tube Rupture Page 2 APS will provide for NRC review an analysis which contains, as a minimum, the results of APS'nvestigation into the root cause of the steam generator tube rupture, corrective actions, and the basis for restart of PVNGS Unit 2.

APS will meet with the NRC to discuss this analysis following its submittal. PVNGS Unit 2 willnot be restarted until these matters have been addressed and startup has been discussed with the NRC.

Should you have any questions, please contact Ronald J. Stevens at (602) 393-5600.

Sincerely, WFC/RJS/rlw cc:

B. H. Faulkenberry J. A. Sloan C. M. Trammell

)

s h

0 fp h) 4 e~

I

/f 1

h h

iJ i