ML17306B426

From kanterella
Jump to navigation Jump to search
Forwards LER 92-005-01 Re Main Steam Safety Valve as-found Relief Settings Out of Tolerance Limits in TS 3.7.1.1.Suppl Updates Valve Testing Schedule in Section Iii.B & Provides Main Steam & Pressurizer Safety Valve Test Results
Date released: 07/31/2018 Download: ML17306B426


LER 92-005-01:on 921023,determined That 11 of 20 Main Steam Safety Valve as-found Relief Setpoints Out of TS 3.7.1.1 Tolerance from 921010-23.Possibly Caused by Setpoint Drift. Valves Will Be Removed & Shipped to Offsite Facility
ML17306B427
Person / Time
Site: Palo Verde 
Issue date: 04/24/1993
From: Bradish T
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To:
References
Download: ML17306B427 (16)
Forwards LER 92-005-01 Re Main Steam Safety Valve as-found Relief Settings Out of Tolerance Limits in TS 3.7.1.1.Suppl Updates Valve Testing Schedule in Section Iii.B & Provides Main Steam & Pressurizer Safety Valve Test Results
ML17306B425
Person / Time
Site: Palo Verde 
Issue date: 04/24/1993
From: James M. Levine
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML17306B425 (4)