ACCELERATED DISTRIBUTION DEMONSTPWTION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
CESSION NBR:9202060092 DOC.DATE: 92/01/28 NOTARIZED:
NO DOCKET ACIL:STN-50-528 Palo Verde Nuclear Station, Unit 1, Arizona Publi 05000528 AUTH.NAME AUTHOR AFFILIATION CONWAY,W.F.
Arizona Public Service Co.
(formerly Arizona Nuclear Power RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)
SUBJECT:
Responds to NRC 911231 ltr re violations noted in insp rept 50-528/90-42-06.Corrective actions:fifty-two of one hundred
& five sys have been completed.
DISTRI'ECTION CODE:
IEOID COPIES RECEIVED:LTR ENCL + SIZE:
TITLE: General (50 Dkt)-Insp Rept/Notice of Vio ation Response D
NOTES:STANDARDIZED PLANT 05000528 /
RECIPIENT ID CODE/NAME PD5 PD THOMPSON,M INTERNAL: ACRS AEOD/DEIIB DEDRO NRR MORISSEAU,D t
NRR/DLPQ/LPEB10 NRR/DREP/PEPB9H NRR/PMAS/ILRB12 OE DT:R,.-~~
RE
'FILE
>2
/
EXTERNAL EGGG/BRYCE iJ
~ H ~
NSIC NOTES'OPIES RECIPIENT LTTR ENCL ID CODE/NAME TRAMMELL,C AEOD AEOD/DSP/TPAB NRR HARBUCKi C NRR/DLPQ/LHFBPT NRR/DOEA/OEAB NRR/DST/DIR 8E2 NUDOCS-ABSTRACT OGC/HDS1 RGN5 FILE-01 NRC PDR COPIES LTTR ENCL D
D D
NOTE TO ALL"RIDS" RECIPIENTS:
D D
PLEASE HELP US TO REDUCF. O'ASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOK! P 1-37 (EXT. 20079) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!
<<OTAL NUMBER OF COPIES REQUIRED:
LTTR 26 ENCL
/
l 0
, t
WILLIAMF. CONWAY EXECUTIVEVICEPRESIDENT NUCLEAR Arizona Public Service Company P.O, BOX 53999
~
PHOENIX, ARIZONA85072-3999 102-02109-MF C/TRB/RJR January 28, 1992 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Mail Station: P1-37 Washington, DC 20555
Reference:
Letter No. 102-01974, dated February 4, 1991, from W. F. Conway, Executive Vice President, Nuclear, Arizona Public Service Company.to the U. S. Nuclear Regulatory Commission.
0
Dear Sirs:
Subject:
PALO VERDE NUCLEAR GENERATING STATION (PVNGS)
UNITS 1, 2, AND 3 DOCKET NOS. 50-528/529/530 PM TASK FORCE COMPLETION DATE REVISION RE: REPLY TO NOTICE OF VIOLATION528/90-42-06 File: 92-070-026 The referenced letter provided Arizona Public Service Company's (APS) response to NRC Notice of Violation 50-528/90-42-06.
The response stated that a PM Task Force had been created to review and evaluate each PM task on a system by system basis.
This review was expected to be completed by'ecember 31, 1991.
On November 6, 1991, APS met with NRC and presented the status of the project.
During that meeting APS stated that fifty-twoof the one hundred and five systems had been completed.
This included the multi-discipline safety-related systems and seven systems identified as important to the Probablistic Risk Assessment.
However, the review process has taken longer than originally planned, and review of the remaining systems is now expected to be completed by August 1, 1992.
lf you should have any questions or require additional information, please contact Mr. T. R. Bradish at (602) 393-2521.
Sincerely, WFC/TRB/RJR/dmn
'II2020b00'V2 920128 PDR ADOCK 05000528 8
PDR i(~0(
I'
NRC Document Control Desk Page 2 102-02109-WFC/TRB/RJR cc:
J. B. Martin D. H. Coe C. M. Trammell A. H. Gutterman A. C. Gehr
l 1
'I