Suppls 910621 Response to Suppl 2 to NRC Bulletin 89-001 Re Failure of Westinghouse Steam Generator Tube Mechanical Plugs.Westinghouse Inconel 600 Plugs Replaced W/Inconel 690 Plugs at Unit 2.No Subj Plugs Installed in Units 1 or 3
ML17305B669
Person / Time
Site: Palo Verde  
Issue date: 07/31/1991
From: Conway W, James M. Levine
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
161-04081-WFC-J, 161-4081-WFC-J, IEB-89-001, IEB-89-1, NUDOCS 9108060275
Download: ML17305B669 (8)


Text

ACCELERATED DIS UTION DEMONSTR 7ION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9108060275 DOC DATE: 91/07/31 NOTARIZED: YES DOCKET FACIL:STN-50-528 Palo Verde Nuclear Station, Unit 1, Arizona Publi 05000528 STN-50-529 Palo Verde Nuclear Station, Unit 2, Arizona Publi 05000529 STN-50-530 Palo Verde Nuclear Station, Unit 3, Arizona Publi 05000530 AUTH.NAME AUTHOR AFFILIATION CONWAY,W.F. 'rizona Public Service Co. (formerly Arizona Nuclear Power LEVINE/J-M.

Arizona Public Service Co.

(formerly Arizona Nuclear Power RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document'ontrol Desk)

D

SUBJECT:

Suppls 910621 response to Suppl 2 to NRC Bulletin 89-001 re failure of Westinghouse steam generator tube mechanical plugs. Westinghouse Inconel 600 plugs replaced w/Inconel 690 S

plugs at Unit 2.No subj plugs installed in Units 1 or 3.

/

DISTRIBUTION CODE:

IE31D COPIES RECEIVED:LTR LENCL +

SIZE:

NOTES:STANDARDIZED PLANT Standardized plant.

Standardized plant'.

05000528 05000529 05000530 RECIPIENT ID CODE/NAME PD5 LA TRAMMELL,C COPIES LTTR ENCL RECIPIENT ID CODE/NAME PD5 PD THOMPSON,M COPIES LTTR ENCL INTERNAL: AEOD/DOA NRR/D@T/EMCB 9H NRR/DOEA/OEAB11 NRR/DREP/PEPB9D NRR/PMAS/ILRB12 RES/DSIR/EIB EXTERNAL: NRC PDR NOTES:

AEOD/DSP/TPAB NRR/DET/EMEB 7E NRR/DOEA/OGCB11 NRR/DS'!'E2

~&~+8 02~

RGN5 FILE 01 NSIC R'

S

/

NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE! CONTACTTHE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 19 ENCL D

D s

0 L

,I t

Arizona Public Service Company P.O. BOX 53999

~

PHOENIX. ARIZONA85072-3999 WILLIAMF. CONWAY EXECUTIVEVICEPRESIOENT NUCLEAR Docket Nos.

STN 50-528/529/530 161-04081-WFC/JMQ July 31, 1991 U.

S. Nuclear Regulatory Commission Attn:

Document Control Desk Mail Station Pl-37 Washington, D.

C.

20555

References:

A)

Addendum 2 to Revision 3 of Westinghouse reports WCAP-12244 (proprietary version) and WCAP-12245 (non-proprietary version),

"Steam Generator Tube Plug Integrity Summary Report,"

May 1991 B)

Letter from APS, to NRC, 161-04017-WFC, dated June 21, 1991;

Subject:

NRC Bulletin 89-01 and Supplement 1 "Failure of Westinghouse Steam Generator Tube Mechanical Plugs C)

Letter from C.

E.

Rossi, NRC, to All holders of operating licenses or construction permits for pressurized-water
reactors, dated June 28, 1991;

Subject:

NRC Bulletin No. 89-01, Supplement 2, Failure of Westinghouse Steam Generator Tube Mechanical Plugs

Dear Sirs:

Subj ect:

Palo Verde Nuclear Generating Station (PVNGS)

Units 1, 2,

and 3

NRC Bulletin No. 89-01, Supplement 2, Fai.lure of Westinghouse Steam Generator Tube Mechanical Plugs File:

91-055-026 NRC Bulletin 89-01 requested addressees to 1) verify that information contained in Table 2 of Reference A for their plants is correct for plugs fabricated from group 2 heats, and 2) repair or replace the plugs as required by the schedule stated in the Bulletin.

As stated in Reference C, Arizona Public Service Company (APS) identified that 95 Westinghouse Inconel 600 steam generator tube plugs had been installed in Unit 2.

These 95 Westinghouse Inconel 600 steam generator tube plugs have been replaced with Inconel 690 mechanical tube plugs during the Unit 2, Cycle 3

refueling outage.

Since APS has replaced the Inconel 600 steam generator tube plugs, verification of the information contained in Table 2 of Reference A was not necessary and actions taken to replace the plugs are completed.

PVNGS does not have any Inconel 600 steam generator tube plugs installed in the other units.

9108060275 910731 PDR ADOCK 05000523 0

'A A/9

161-04081-WFC/JMQ July 31, 1991 U.

S. Nuclear Regulatory Commission Attn: Document Control Desk Bulletin No. 89-01 Page 2

If you should have any questions or require additional information, please contact Michael E. Powell of my staff at (602) 340-4981.

Sincerely, WFC/MEP/JMQ/jmq cc:

J.

B. Martin D. H.

Coe A. C. Gehr A. H. Gutterman

161-04081-WFC/JMQ July 31, 1991 STATE OF ARIZONA

)

) ss.

COUNTY OF MARICOPA )

I.

J.

M.

Levine, represent that I am Vice President Nuclear Production, that the foregoing document has been signed by me on behalf of Arizona Public Service Company with full authority to do so, that I have read such document and know its contents, and that to the best of my knowledge and belief, the statements made therein are true and correct.

J.

M. Levine Sworn To Before Me This ~H Dey Of~,

1991.

tary Public My Commission Expires My Commission Expires April 6, 1995

l1 ff ll I