ML17305B617

From kanterella
Jump to navigation Jump to search
Documents Closure of NRC Bulletin 89-001 & Suppl 1, Failure of Westinghouse Steam Generator Tube Mechanical Plugs. Util Removed 95 Westinghouse Inconel 600 Tube Plugs & Replaced Plugs W/Inconel 690 Plugs During Unit 2 Cycle 3 Outage
ML17305B617
Person / Time
Site: Palo Verde  Arizona Public Service icon.png
Issue date: 06/21/1991
From: Conway W
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
161-04017-WFC-J, 161-4017-WFC-J, IEB-89-001, IEB-89-1, NUDOCS 9107020400
Download: ML17305B617 (4)


Text

ACCELERATED ISTRIBUTION DEMOI'eIRATION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9107020400 DOC.DATE: 91/06/21 NOTARIZED:

NO DOCKET FACIL:STN-50-528 Palo Verde Nuclear Station, Unit 1, Arizona Publi 05000528 STN-50-529 Palo Verde Nuclear Station, Unit 2, Arizona Publi 05000529 STN-50-530 Palo Verde Nuclear Station, Unit 3, Arizona Publi 05000530 AUTH.NAME AUTHOR AFFILIATION CONWAY,W.F-Arizona Public Service Co.

(formerly Arizona Nuclear Power RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Documents closure of NRC Bulletin 89-001

& Suppl 1, "Failure of Westinghouse Steam Generator Tube Mechanical Plugs." Util removed 95 Westinghouse Inconel 600 tube plugs

& replaced plugs w/Inconel 690 plugs during Unit 2 Cycle 3 outage.

DISTRIBUTION CODE:

IE31D COPIES RECEIVED:LTR Q ENCL 0 SIZE:

I TITLE: Bulletin Response 89-01 re Failure of Westinghouse Steam Gen.

Mech.

T A NOTES:STANDARDIZED PLANT 05000528 Standardized plant.

05000529 D

Standardized plant.

05000530 D

RECIPIENT ID CODE/NAME PD5 LA TRAMMELL,C INTERNAL: AEOD/DOA NRR/DET/EMCB 9H NRR/DOEA/OEAB11 NRR/DREP/PEPB9D NRR/PMAS/ILRB12 RES/DSIR/EIB EXTERNAL: NRC PDR NOTES:

COPIES LTTR ENCL RECIPIENT ID CODE/NAME PD5 PD THOMPSON,M AEOD/DSP/TPAB NRR/DET/EMEB 7E NRR/DOEA/OGCB11 NRR/J3SZ E2 REG FILE GN-Ol NSIC COPIES LTTR ENCL D

'OTE TO ALL"RIDS" RECIPIENTS:

D D

PLEASE HELP US TO REDUCE iVASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEEDl TOTAL NUMBER OF COPIES REQUIRED:

LTTR 19 ENCL

I

Arizona Public Service Company P.O. BOX 53999

~

PHOENIX. ARIZONA85072-3999 WILLIAMF, CONWAY EXECIIJTIVEVICE PRESIDENT NUCLEAR 161-04017-WFC/JMQ June 21, 1991 Docket Nos.

STN 50-528/529/530 U.

S. Nuclear Regulatory Commission Attn:

Document Control Desk Mail Station Pl-37 Washington, D.

C.

20555

Reference:

Letter from W.

F.

Conway, APS (161-01990-WFC),

to NRC Document Control Desk, dated June 2,

1989; Subjec":

"Response to Actions Requested of NRC Bulletin 89-01"

Dear Sirs:

Subj ect:

Palo Verde Nuclear Generating Station (PVNGS)

Units 1, 2,

and 3

NRC Bulletin 89-01, and Supplement 1 "Failure of Westinghouse Steam Generator Tube Mechanical Plugs" File:

91-056-026 This letter documents Arizona Public Service Company's (APS') closure of NRC Bulletin 89-01, and Supplement 1 "Failure of Westinghouse Steam Generator Tube Mechanical Plugs,"

as requested by Mr. C.

M. Trammell, NRC Project Manager.

In the referenced letter, APS responded to the bulletin and committed to remove or repair the tube plugs of the affected hea't treat. numbers during the Unit 2, Cycle 3 refueling outage.

APS has removed the 95 Westinghouse Inconel 600 mechanical tube plugs that were identified in Table 1 of the referenced letter, and replaced them with Inconel 690 mechanical tube plugs during the Unit 2, Cycle 3 refueling outage.

If you should have any questions, please contact Michael E. Powell of my staff at (602) 340-4981.

Sincerely, WFC/JMQ/sad cc:

J.

B. Martin D.

H.

Coe A.

C.

Gehr A. H. Gutterman 9107020400

'$10621 PDR ADOCK II5000528 P1:IR

I I

N