ML17305B382
| ML17305B382 | |
| Person / Time | |
|---|---|
| Site: | Palo Verde |
| Issue date: | 12/31/1990 |
| From: | Conway W ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR |
| To: | NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES) |
| References | |
| 161-03784-WFC-J, 161-3784-WFC-J, NUDOCS 9103110111 | |
| Download: ML17305B382 (8) | |
Text
ACCELERATED DISTRIBUTION DEMONSTRATION -SYSTEM
-941%8!%t " ":
.Il Unit 1, Arizona Publi 05000528 Unit 2, Arizona Publi 05000529 Unit 3, Arizona Publi 05000530 ACCESSION NBR:9103110111 DOC.DATE:.
FACIL:STN-50-528 Palo Verde Nuclear Station, STN-50-529 Palo Verde Nuclear Station, STN-50-530 Palo Verde Nuclear 'Station, AUTH.NAME AUTHOR AFFILIATION CONWAY,W.,F.
Arizona Public 'Service Co.
RECIP.NAME RECIPIENT AFFILIATION C
(formerly Arizona Nuclear Power R'EGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
SUBJECT:
"Personnel Monitoring Rept for 1990."
910228 tr.
DISTRIBUTION CODE:
IE56D COPIES RECEIVED:LTR g ENCL + SIZE:
TITLE: 20.407 Annual Personnel Monitoring Rpt/Annual Rad Exposure NOTES:STANDARDIZED PLANT
.Standardized plant.
Standardized plant.
D pt y Fun 05000528 05000529 05000530 A
D RECIPIENT ID CODE/NAME PD5 LA TRAMMELL,C INTERNAL: ACNW NRRJlOZA OEAB 1 RE RGN5 01 COPIES LTTR ENCL 1
RECIPIENT ID CODE/NAME PD5 PD THOMPSON,M AEOD/DSP/TPAB NRR/DREP/PRPB11 RES RADDATZ,C COPIES LTTR ENCL 5
1 D
EXTERNAL: NRC PDR NOTES:
1 NSIC 1
1 D
NOTE TO ALL"RIDS" RECIPIENTS:
D D
PLEASE HELP'US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM P 1-37 PXT. 20079) TO ELIMINATEYOUR NAMEFROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED:
LTTR 25 ENCL ~
(3.
0
Arizona Public Service Company P.O. BOX 53999
~
PHOENIX, ARIZONA85072-3999 WILLIAMF. CONWAY EXECUTIVEVICEPRESIDENT NUCLEAR 161-03784-WFC/JRP
'ebruary 28, 1991 Docket Nos.
STN 50-528/529/530 Director Office of Nuclear Regulatory Research
.U.
S. Nuclear Regulatory Commission Washington, D.
CD 20555
Dear Sir:
Sub) ect:
Palo Verde Nuclear Generating Station (PVNGS)
Units 1, 2, and 3
Personnel Monitoring Reports for 1990 File: 91-019-026 Pursuant to 10 CFR 20.407 and as supplemented by PVNGS Technical Specification 6.9.1.5, please find enclosed a copy of the Personnel Monitoring Report for 1990, which is submitted in accordance with paragraph (a) (2) of this part.
If you have any questions, please contact Michael E.
Powell of my staff at (602) 340-4981.
Sincerely, WFC/JRP/pmm Attachment cc:
J.
B. Martin D. H.
Coe A.
CD Gehr A. H. Gutterman 9i03iiolil 90l23i PDR ADDCK 0500052:=
R PDR gr
Il
PAGE:
1 ANpp/pvNGs RADIGIGGIcAL REcoRDs a AccEss coNTR0L NRC REG GUIDE 1.16 REPORT (FOR THE YEAR 1990)
DATE: Ol/27/91 TIME: 06:32:20 SYSTEM
'risona Nuclear Power Project P.O.
Box 52034
- Phoenix, AZ 85072-2034 Palo Verde Nuclear Geneiation Station NRC-L'icense No.
NPF-41 NPF-51 NPF-74 Number of Personnel
()
100mR)
Total Man-Rem Work t Job Function station IUtility IContiact Employees IEmployees IWorkers IIStation IUtility IContract IIEmployees IEmployees Workers II I
REACTOR OPERATIONS
% SURVEILLANCE Maintenance Personnel Operating Personnel Health Physics Personnel Supervisory Personnel Engineerihg Personnel ROUTINE MAINTENANCE Maintenance Personnel Operating Personnel Health Physics Peisonnel Supervisory Personnel Engineering Personnel-INSERVICE INSPECTION Maintenance Personnel operating Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel SPECIAL MAINTENANCE Maintenance Personnel Operating Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel WASTE PROCESSING Maintenance Personnel Operating Personnel Health Physics Perionnel Supervisory Personnel Engineering Personnel REFUELING Maintenance Personnel
.Operating Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel TOTAL Maintenance Personnel Operating Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel GRAND TOTAL 0
57 45 122 3
48 0
5 9
0 7
0 6
0
.0 0
1 0
0 17 0
0 19 2
6 2
1 154 62 123 3
14 356 I
I I
I I
I I
I-I I
I I
0 0
I I
o I
0 0
0 0
I 0
0 0
I 0
I 0 'I 0
0 106 0
6 265 22 114 2
16 112 5
36 2
28 11 0
2 0
0 1
1 18 1
0 102 3
61
,1 0
491 31 337 6
50 915 IIIIIIIIIIIIII I I.
I I
III
~
IIIIIIII I
IIIIII I
I I
I I
I IIIIIIIIIIIII-I 1.2321 17.2131 11.4891 0.7001 1 0141 I
45.8421 2.6491 15.6351 0.2251 2.8291 I
3.2731 0.1601 1.7381 0.090 1.715 1 ~ 2491 0.0101 0.010
,0.000
- 0.350 0.030 0.2201 5.5071 0.0301 0:0001 6.829 1.500 2.6781 0.6451 0.4401, I
58.4551 21.7521 37.0571 1.6901 6.3481 I
125.3021 0.000 0.0001 0.0001 0.000 0.000 0.0001 0 ~ 0001 0.0001 0.0001 0.0001 I
0;0001.
0;000 0.000 0.000
-,0.000 0.000 0.000 0.000 0 000 0.000 0.0001 0.0001 0.0001 0.0001 0.0001 0 ~ 000 0.000 0.0001
, 0.0001 0.0001 I
0.0001 0.0001 0.000 0.000 0.000 0.0001 2.357 1.2131 30.052 0.030 2.101 117 '231 5.0351 37.486 0.490 7 '12 60 '82 1.565 11.5531 2 '84 11.005 3.870
- 0. 010 0;685 0.000 0.000 0.865 0.845 6.189 0;110 0 ~ 000 50.508 1.288 16.842
-0.2301 0.905 235.105 9.956 102.807 3;0441 21.823 372.735
Il 0
I Er
ANPP/PVNGS RADIOLOGICALRECORDS
& ACCESS CONTROL SYSTEM 10-CFR-20 STATISTICAL,
SUMMARY
REPORT (FOR THE YEAR OF 1990)
DATE: 01/27/91 TIME: 10:05:41 Arizona Nuclear Power Project P.O.
Box 52034
- Phoenix, AZ 85072-2034 ESTIMATED WHOLE BODY EXPOSURE RANGE (R1M),
Palo Verde Nuclear
,Generation Station NRC-License No.
NPF-41 NPF-51 NPF-74 NUMBER OF INDIVIDUALS'N EACH RANGE No Measurable Exposure
) Measurable Exposure Less Than 0.1 0.1 to '0.25
) 0.25 to 0.5 0.5 to 0.75
[ 0.75 to 1 1to2
'2 to3 3to4 4to5 5to6 6to7 7to8 8 to9 9 to 10 10 to 11 11 to 12 2842 1179 476 310 50 102 0
0 0
Individuals values exactly equal to the values separating exposure ranges shall be reported in the higher range
I!
t A