ACCELERATED DISTRIBUTION DEMONSTRATION SYSTEM REGULA RY INFORMATION DISTRIBUTI SYSTEM (RIDS)

ACCESSION NBR:9005240157 DOC.DATE: 90/05/15 NOTARIZED: NO DOCKET FACIL:STN-50-529 Palo Verde Nuclear Station, Unit 2, Arizona Publi 05000529 AUTH.NAME AUTHOR AFFILIATION LEVINE,J.M.

Arizona Public Service Co. (formerly Arizona Nuclear Power RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Forwards Special Rept 2-SR-90-002 re steam generator tube plugging due to inservice insp activities. Twenty tubes plugged in Steam Generator 1

a ninety-one tubes plugged in Steam Generator 2.

DISTRIBUTION CODE:

A047D COPIES RECEIVED:LTR J ENCL Q SIZE:

TITLE: OR Submittal: Inservice Inspection/Testing/Relief from ASME Code D

NOTES:Standardized plant.

05000529 RECIPIENT ID CODE/NAME PD5 LA PETERSONPS.

INTERNAL: ACRS NRR/DET/ECMB 9H NUDOCS-ABSTRACT OGC/HDS1 RES/DSIR/EIB EXTERNAL: EGGG BROWN,B LPDR NSIC COPIES LTTR ENCL 1

0 1

1 6

6 1

1 1

1 1

0 1

1 1

1 1

1 1

1 RECIPIENT ID CODE/NAME PD5 PD CHAN,T AEOD/DSP/TPAB NRR/DET/EMEB 9H OC LFM REG FILE 01 EGGG RANSOMEPC NRC PDR COPIES LTTR ENCL 5

5 1

1 1

1 1

1 1

0 1

1 1

1 1

1 D

D NOTES:

1 1

D I

~ Ccreeck PQD5 c

iS pr/gallon NOTE TO ALL"RIDS" RECIPIENTS:

A D

D PLEASE HELP US TO REDUCE WAS'ONTACTTHE DOCUMENT CONTROL DESK, ROOM P 1-37 (EXT. 20079) TO ELMINATEYOUR NAMEFROM DISIRIBUTION LISIS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 28 ENCL 25

~

~

If

jl~~

1 Arizona Public Service Company PALO VERDE NUCLEAR GENERATING STATION P.O. BOX 52034

~

PHOENIX, ARIZONA 85072-2034 JAMES M. LEVINE VICE PRESIDENT NUCLEAR PRODUCTION 192-00662-JML/TRB/RKR May 15, 1990 U.

S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555

Dear Sirs:

Subj ect:

Palo Verde Nuclear Generating Station (PVNGS)

Unit 2 Docket No.

STN 50-529 (License No. NPF-51)

Special Report 2-SR-90-002-00 File'0-020-404 Attached please find Special Report 2-SR-90-002 prepared and submitted pursuant to Technical Specifications 4.4.4.5 and 6.9.2.

This report discusses steam generator tube plugging in Unit 2.

If you have any questions, please contact T. R. Bradish, Compliance Manager at (602) 393-2521.

Very truly yours, JML/TRB/RKR/tlg Attachment cc:

W. F.

J.

BE D. H.

T. L.

A. C.

A. L.

Conway Martin Coe Chan Gehr Gutterman (all with attachment)

~voosososo7 9oosio PDR ADOCK 0500O>~'II'

v Ql 4

PALO VERDE NUCLEAR GENERATING STATION UNIT 2 Steam Generator Tube Plugging License No. NPF-51 Docket No. 50-529 Special Report 2-SR-90-002 This special report is provided pursuant to Palo Verde Unit 2 Technical Specifications 4.4.4.5(a) and 6.9.2 to report the number of steam generator tubes plugged as a resul't of inservice inspection activities.

On May 3, 1990, Unit 2 was in 'a refueling outage with the core off-';loaded'to. the Spent Fuel Pool'hen an ins'ervice inspe'ction of both steam generators was completed.

The inspection resulted in the plugging of twenty (20) tubes in Steam Generator, No. 1 and ninety-one (91) tubes in.Steam Generator No.

J 2.

IJ Pursuant to Technical Specification 4.4.4.5(b),

the complete results of the steam generator'tube inservice,inspectionwill be submitted by May 3, 1991.

c

~

~o.

ci 1l il

'I

,P