Text

gCCE~~P~<

])3+gBUTJOY DEMONST30.'i SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:8902130370 DOC.DATE: 89/01/31 NOTARIZED: NO DOCKET FACIL:STN-50-528 Palo Verde Nuclear Station, Unit 1, Arizona Publi 05000528 STN-50-529 Palo Verde Nuclear Station, Unit 2, Arizona Publi 05000529

. STN-50-530 Palo Verde Nuclear Station, Unit 3, Arizona Publi 05000530 AUTH.NAME AUTHOR AFFILIATION EARNER,D.B.

Arizona Nuclear Power Project (formerly Arizona Public Serv RECIP.NAME RECIPIENT AFFILIATION R

Document Control Branch (Document Control Desk

SUBJECT:

Forwards final rept on pressure-temp limits re Generic Ltr 88-11,"Radiation Embrittlement of Reactor Vessel....,."

D DISTRIBUTION CODE: B008D COPIES RECEIVED:LTR 2 ENCL 2 SIZE: c8+++

TITLE: OR/Licensing Submittal: Reactor Vessel Material Surveillance Report NOTES:Standardized plant.

05000528/

Standardized plant.

05000529 Standardized plant.

05000530~

D RECIPIENT ID CODE/NAME PD5 LA CHAN,T DAVIS,M.J.

COPIES LTTR ENCL 1

0 1

1 1

1 RECIPIENT ID CODE/NAME PD5 PD DAVIS,M COPIES LTTR ENCL 5

5 1

1 INTERNAL: ACRS NRR/DE ST/ADS 7E NRR/DEST/ESB 8D NRR/DEST/RSB 8E NRR/PMAS/ILRB12 OGC/HDS1 RES/DSIR/EIB EXTERNAL: LPDR NSIC NOTES 6

ARM/DAF/LFMB 1

NRR/DEST/CEB 8H 1

NRR/DEST/MTB 9H 1

NRR/DOEA/TSB 11 1

~CQ AB RACT 0

REG FILE 01 1

RES/

1 1

NRC PDR 1

1 ORNL KAM,F 1

1 1

0 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 h

NOTE 'lO ALL "RIDS" RECIPIENTS'LEASE HELP US jO REDUCE HASTE CXWZACZ '%HE DOCUMENT CONTROL DESK g ROOM Pl-37 (EXT. 20079)

'lO EL3MZATE YOUR NAME PBCH DISTJGEUTIQN LXSTS FOR DOCUMENTS YOU DOIN'T NEEDz TOTAL NUMBER OF COPIES REQUIRED:

LTTR 33 ENCL 30

4~

~~

'C P

g

'I

Arizona Nuclear Power Project P.O, BOX 52034

~

PHOENIX. ARIZONA 85072-2034 161-01657-DBK/PGN January 31, 1989 Docket Nos.

STN 50-528/529/530 Document Control Desk U.

S. Nuclear Regulatory Commission Mail Station Pl-137 Washington, D.C.

20555

Dear Sirs:

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Units 1, 2, and 3

Generic 'Letter 88-11 Radiation Embrittlement of Reactor Vessel Materials File:

89-A-056-026 As required by NRC Generic Letter 88-11, the Palo Verde Reactor Vessel Pressure-Temperature (P-T) limits have been developed in accordance with 10 CFR Part 50 Appendix G, utilizing the material irradiation damage prediction methods of Regulatory Guide 1.99 Revision 02.

Low Temperature Overpressure Protection (LTOP) enable temperatures have also been determined.

The results of the technical analysis are attached.

As a

result of utilizing the new irradiation damage prediction method of Regulatory Guide 1.99 Revision 02, an LTOP analysis to identi.fy the LTOP restrictions associated with the new P-T limits is required.

Following completion of this analysis, an assessment of the Palo Verde heatup and cooldown

rates, administrative restrictions, and NRC changes to Standard Review Plan 5.2.2 will be performed to ensure compatibility between the P-T limits and the LTOP analysis.

Technical Specification changes will be developed to incorporate the results of the analyses when complete.

The Technical Specification changes for 0 to 10 calendar years of full power operation are expected to be submitted to NRC for approval by November 20,, 1989.

Administrative procedures will be updated within thirty days of receipt of the Technical Specification amendments.

Pressure-Temperature limits and.corresponding LTOP restrictions for 10 to 40 calendar years of full power operation will continue to be analyzed as changes to Standard Review Plan 5.2.2 and Palo Verde surve'illance capsule data become available.

8902130370 890i31 PEER ADOCK 05000528 P

PDC ooC I

I

~P

~,

Document Control Desk Page 2

161-01657-DBK/PGN January 31, 1989 If you have any questions, please call Mr. A. C. Rogers at,(602) 371-4041.

Very truly yours, D. B; Karner Executive Vice President DBK/PGN/d116 cc:

G.

W. Knighton T. L. Chan M. J

~ Davis J.,B..Martin T. J. Polich

4l