Salt Deposition and Impact Monitoring Plan for The Palo Verde Nuclear Generation Stations Units I, 2, and 3

(Rev.

5)

Prepared For Arizona Nuclear Power Project Prepared By NUS Corporation 910 Clopper Road Gaithersburg, Maryland April 1987 f707 130083 ~ 500052S 70'~

pDR P DOC(

PDR P

0

Table of Contents

1. 0 Introduction Page
2. 0 Monitoring Program Design
2. 1 Selecti.on of Monitoring Locations 2.2 Sampling Methods
2. 2.1 Soil Sampling
2. 2. 2 Indigenous and Agricultural Vegetation Sampling
2. 2. 3 Salt Deposition Sampling
2. 2. 4 Airborne Salt Sampling 2; 2.5 Sampling Schedule
2. 3 Sample Analysis
2. 4 Data Review 2.5 equality Assurance Program 2-1 2-1 2-6 2-6 2-7 2-7 2-8 2-8 2-9 2-10 2-10 Note:

Changes to this document are noted in the margins on each page with identifying numbers representing the revision.

The original issue was in February 1983; a Revision 1 was prepared but never issued, being superseded by Revision 2, dated April 1983.

~ '

List of Tables Table 2-1 2-2 Salt Monitoring Program for PVNGS Summary of the Types of Sampling to'e Performed for Each Sampling Location Program Sampling Schedule Page 2-3 2-9 List of Figures Figure 2-1 Distribution of Soil and Dustfall Sampling Locations Page 2-2 2-2 Distribution of Vegetation Sampling Locations 2-5

l. 0 INTRODUCTION This document presents the design of an environmental monitoring program to determine the environmental impact, if any, due to salt drift from operation of the PVNGS mechanical draft cooling towers.

It is designed to meet the commitment for a monitoring, program contained in the Environmental

Report, Construction Phase.

Table l-l is a summary of this coranitment.

Table l-l.

Salt Monitoring Program for PVNGSa Plant System Predicted Physical Biotic Inducing Physical Parameter Indicator Change Change to be to be Monitored Monitored Duration and Periodicity of Study Preoperation Operation Period Period Drift from cooling tower salt Foliar Airborne Salt deposition salt sensitive of salt plant species Basel inc seasonal data one year prior to opera-tion Seasonal data until level of impact determined aEnvi ronmental Report - Construction Permit Stage, Section

6. 2. 5.

The monitoring program (1) determines levels of airborne salt deposition, (2) defines physical and chemical properties of surficial soils, (3) estimates species richness and cover and measures salt loading of the indigenous natural plant communities, and (4) measures salt loading and yield of cotton.

Comparisons of these parameters are made at sampling locations between the period prior to operation and the period during operation of one,

two, and three units.

There are also several control sites, which are used as back-ground locations not affected by operation of the cooling towers, that give an indication of any long term changes.

1-1

2. 0 MONITORING PROGRAM DESIGN This section presents a description of the program design and includes a

discussion of the selection of monitoring locations, sampling methods and 3

equipment, laboratory sample

analyses, data review and report preparation, and quality assurance.
2. 1 Selection of Monitoring Locations The monitoring program is conducted both onsi te and offsite out to approxi-mately 20 miles from the cooling towers.

Most of the sampling locations are at distances of five miles or less from the cooling towers.

This 5-mile distance corresponds to that beyond which salt deposition is not predicted to exceed about one pound per acre per year.

Five control sites are included in the monitoring program to measure background levels of salt deposition at distances unlikely to be significantly affected by PVNGS emissions.

Factors considered for the selection of these control site areas included an 2

examination of the potential influences from any of the surrounding topography and their proximity to significant sources of fugitive dust or particulate emissions such as industry.

Two control sites are located approximately 20 miles to the northwest of the cooling towers and two other control sites approximately 15 miles to the southest of the cooling towers.

One control site will be an agricultural area and the other will be in native desert environment for each of these quadrants.

A fifth native vegetation control site is located approximately 7 miles to the northwest of the cooling towers.

A total of 44 sampling locations were selected to meet the following objectives:

o Measure site-originated deposition via dustfall collection, and 2

any changes in vegetation and/or soil chemistry at all nearby agricultural fields.

o Establish background data on salt conditions.

o Provide salt deposition data that could possibly be correlated with ongoing radiological and natural vegetation studies.

o Demonstrate that the monitoring program can detect site-originated salt deposition and determine the geographical limit of detection.

o Provide long-term control plots (at 15 to 20-mile distances and in 3

directions that are least frequently downwind of the cooling 2

towers) for determining background variations in salt levels in the vicinity of PYNGS.

Figure 2-1 shows the approximate locations of the 44 sites for the monitor-4 ing of salt deposition and soil sampling, including the 5 control locations used to determine background changes, if any, in salt levels.

Table 2-1 3

presents a

summary of the types of sampling to be performed at each sampling location.

At the 6 locations footnoted on Figure 2-1, the existing low-2-1

H O

I

~

~ ~

~

S

~

~

w

~

' lh\\

~

~ \\

8 3'

j 0

~

~.

'V 4

r

~

~

~

~

~

~ p

.n

~ \\

I'I.'

~ i~ i-

<<I

~

t IJw,ltMI

~ c I. t I ~

I

~

t

~0 I ~ l H

~II vt 0 i

~p

~VO

~

sr'W.

~a II~

~ 4 ~

I ~

J~f(i r Iran Xg*

,.l...

\\

l

~

~OV IWW I Q

~

e y

~

0 IA

~.

h

~

0 1

a I

4

~

a

~<<I I

~

et

~

4 W

~

~

r c ~ '

0

~

~0

~ At W

~ %T t

~

0

~

0

~

~I FQOCnOC0:

Figure 2-1 Distribution ot Dust tall and Soil Sampling Locations Revision 4

Nay 1, 1985 Low-volume air samplers are located at 8,9,10,20,2i,2l.

V

Table 2-1 Summary of the Types of Sampling to be Performed at Each Sampling Location Sampling Location No.

Airborne Salts Via Dustfall Collection Native Soils Vegetation Agricultural Airborne Salts Via Low Volume Samplers 1

2 3

4 5a 6

?

8 9

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25.

26 27 28 29b 30 31 32 33 34 35 36 X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

2-3

Table 2-1 (Continued)

Summary of the Types of Sampling to be Performed at Each Sampling Location Sampling Location No.

Airborne Salts Via Dustfall Collection Native Soils Vegetation Agricultural Airborne Salts Via Low Volume Samplers 37 38 39 40 41 42 43 44c 45d X

X X

X X

X X

X X

Total 44 13 aNative vegetation communities destroyed by fire in June 1983.

bDecommissioned during June 1984.

Monitoring equipment was destroyed by agricul tural activity.

cEstablished as a native vegetation control site for salt bush in May 1984.

The saltbush plant community at site Number 42 was tilled and the land was converted to agricultural use sometime prior to May 1984.

dBegan operation in July 1984 to replace site Number 29.

2-4

I

d II

~

s<<l

~ l

~

s

'l Ji to

~

~

~

~

~ ~

40

~

~

r

~

Jis l-I

~

~ ~

\\

~ a 44 vv

~

l

~

r ~

~t I<<

oar

~

~

t2 L

13

.+24

~ s

~

7 ~

~

4

}<<

41

~ t-I

~

~

~

~

~

~

~

~

~

~

~

~

23 28

~

30 45fl

~ I 4

3ta ~ 32>..:..

~

~

~

~6 ss"

~ '

% ~

4wa ra st<<,

~

~

~

~

~

~

~

~

Jr sa ItA

<<7

~

~

~

~

~

~

~ i

~

v

<<p

~

~

4

~

~

~

~

~X

.- l Loaondt

~ t-43M

'i 42+ i.

4 I<<<<

A - Ex!stints Nativo Vosotation Plots (6IISito 5 Not Sarnplod Prosontty Duo to Piro

~ - Attrlcutturat Crops l'l3)

+ - Nativo Vottotatlon Control Sitar !3) 4 4

~

~

~<<

~

~ ~

~ <<

Figure 2-2 Distribution of Vegetation Sampling Locations Revision 4

May 1, 1985

volume samplers used for the station radiological monitoring program are 3

used to determine airborne salt concentrations.

At 11 other locations near the site (see Figure 2-2), sampling of the agricultural crops actually under cul tivation are conducted.

At five onsite locations (1, 2, 3, 4 and 6), representative indigenous plant 4

communities of the site, which have been identified and monitored since

1976, are sampled semiannually (spring and fall).

During June 1983, the native vegetation communities at site number 5.were destroyed by fire.

Site number 5 was then and is currently maintained as a sampling site for dust-fall and soils only.

The locations of these five communities, shown in Fig-3 ure 2-2, provide continuity with an ongoing baseline study of native vegeta-tion (see Section 2.2.2.1).

Soil and dustfall monitoring are also conducted at these locations.

The monitoring program has 33 sampling locations within approximately 5

3 miles of the cooling towers.

These locations were selected so that any measurable changes in deposition due to operation of the cooling towers would be detected by the monitoring program.

Additionally, those sampling locations oriented toward the northeast of the towers correspond to the predicted direction for maximum deposition of salt.

Additional criteria used as a basis for selection of the monitoring sites 2

included the specification of their location at a distance from roads adequate to minimize the collection of traffic-generated dust.

2.2 ~S1i h

d The sampling methodologies presented below and described in further detail in the applicable work instructions are designed to assure valid data acqui-sition.

Fi ve separate sampling methodologies are described; one for soils, two for vegetation (i ndigenous and agricultural),

and two for airborne salt.

2.2.1 Soil Sampling At each of the 44 monitoring locations, composite soil samples (bas'ed on 5 cores from each of 2 transects) are collected at the end of tHe dry season (July-August),

and at the end of the wet season (normally February-March);

an additional sampling is conducted at all 13 agricultural sites after cot-ton defoliation.

The sampling procedure (Reference Work Instruction GO 5.2.16.1) follows the DOE gnyi ronmental Measurements Laboratory's HASL-300 Method for soil sampling,<>>

and uses a soil auger to collect 3-inch diameter core samples in depth increments to 30 cm, which are divided into upper and lower segments.

The depth to the break between upper and lower segments is determined in the field for uncultivated soils based on the depth to a textural change.

Cores in cultivated areas are divided into equal upper and lower segments.

All upper segments and all lower segments for each transect are separately combi ned to form 4 composites (2 depth 1

Department of Energy, Environmental Measurements Laboratory, EML Procedures

Manual, HASL-300, New York, NY, undated.

2-6

increments for each of 2 transects) from each of which 2 samples are taken 4

and labelled.

One sample of each composite is shipped to the analytical laboratory for analysis and the other retained in storage.

2.2.2 Indigenous and Agricultural Vegetation Sampling 2.2.2.1 NativeVegetation Representative native plant communities, which have been identified and mon-itored since 1976 to determine baseline conditions, are sampled semi-annually (March/April and August/September).

Eight vegetative study areas 4

are sampled as depicted in Figure 2-2.

The indigenous plant communities of the PVNGS are dominated by creosote and salt bush.

Associated with these are mesquite and several species of cacti.

The vegetative monitoring program conducted within the eight vegeta-tive comrmnities (Reference Work Instruction SRO 5.2.32.2) includes:

The measurement of species richness and relative cover.

The measurement of salt loadingein tissues of the dominant or co-dominant flora (other than cacti).

2.2.2.2 Crop Sampling At each of the 13 agricultural monitoring locations (Figure 2-2), agricul-2 tural crops are'samp1ed (Reference Work Instruction SRO 5.2.32. I) twice each growing season (e.g.,

June and September for cotton) prior to defoliation (or harvest) to determine the amount of plant tissue salt loading.

Addi-4 tionally, cotton yield is obtained by collecting the seed and fiber (boll) from selected cotton plots (Reference Work Instruction SRO 5.2.32. 1) as well as from the Agricultural Stabilization Conservation Service.

2.2.2.3 Infrared Photography In addition to the quantitative vegetative

analyses, both native vegetation and agricultural crops are monitored using infrared photography (Reference Work Instruction SRO 5.2.32.3).

Aerial photography (false color infrared) is performed to coincide with peak vegetative crop productivity for the principal crops grown in a 5-mile radius of PVNGS (e.g.,

August/September for cotton).

This methodology permits the detection of vegetative stress, confirmed by 3

field inspection, whether due -to natural or artificially induced (e.g., salt drift) conditions and provides a documented photographic record of existing environmental conditions.

2.2.3 Salt Deposition Sampling The rate of 'salt deposition is measured by the collection of dustfall samples which are analyzed for salt content.

The dustfall sampling 2-7

s{

(described in ASTM method D1739(2))

is accomplished by placing pairs of open jars at the selected monitoring locations.

Two jars are placed at each sampling location to provide an estimate of sample precision.

The jars are elevated approximately three feet above the ground on stands, with a bird ring placed around the edge of the jar to prevent birds from perching and contaminating the sample.

This height differs from the recom-mended minimum height of eight feet presented in the ASTM method to permit

'he collection of dustfall at the approximate plant crown height.

A chemi-cally inert 1 to 2 mm conical screen is hung above the maximum water level in the jars to keep out any potential contaminants such as insects.

The monthly sampling (Reference Work Instruction EMD 5.2. 17.27) follows the ASTM method for collection of dustfall, except for Section 9.1.2 (Preservation).

This section, calling for the use of an algicide (CuS04) was determined to be inapplicable and unnecessary at PVNGS in April 1987.

At the end of each month the jars are collected and replaced by a clean set of jars.

The collected jars are rinsed to tr ansfer the samples to shipping bottles which are labeled and sent to a laboratory for analysis.

At least one inch of water is maintained in the jars to prevent collected dust from being blown out.

An 18-inch deep ASTM jar used for dustfall collection is the most suitable collection jar for sampling in a desert environment; it requires less frequent checking and replenishment of the water level than

other, shallower jars.

2.2.4 Airborne Salt Sampling Airborne salt concentrations are measured by collecting particles on a low-3 volume particulate sampler.

Measurements are taken from the six existing low volume samplers (Figure 2-1) being used as part of the radiological mon-itoringg program.

The samplers are made by Schmidt, Inc.,

and draw air through a 50 mm diameter filter.

The filters are collected weekly for radi-4 ological analysis and are composited for the additional chemical analyses on a monthly basis.

2.2.5 Sampling Schedule The monitoring program frequency for salt deposition is generally on a

monthly basis.

Although the low-volume particulate filters are collected weekly, the filters collected during any one month are combined and processed'as one collective sample for each site.

Other exceptions include:

native vegetation, sampled twice each year, in March/April and in September/

October; agricultural sampling in June/July and again with aerial photog-raphy in August/September; and soils sampled at the end of the rainy (nor-mally February/March),

and the dry seasons (July/August) and post-defolia-tion (November).

The dustfall samples and low-volume sampler filters are analyzed on a regular monthly schedule.

Cooling tower basin water is sampled at least quarterly to provide the chemical composition data used as a basis for compari son with the analyses of deposited and airborne material American ociety o

esting and Materials (ASTM), Standard Method for Collection and Analysis of Dustfall (Settleable Particulates)

D1739-70, Annual Book of ASTM Standards, Part 26, Philadelphia, PA., 1970.

F 2-8

samples.

Table 2-2 summarizes the sampling schedule for components of the program.

Samples collected during this program are sent to selected laboratories for the indicated analyses.

The laboratory procedures adopted for analysis of soils, vegetation,

water, and dustfall are documented.

The procedures include the documentation of quality control checks on the instrumentation and the analyses.

Table 2-2.

Program Sampling Schedule COMPONENT MONTH J

F M

A M

J J

A S

0 N

D Particulate Dustfall X

X X

X X

X X

X X

X X

X Airborne Salt Concentration X

(Mo. Avg.)

X X

X X

X X

X X

X X

X Soils X/X X/X Native Vegetation Crops" X /X X/X X/X X/X

'erial Infrared Photography Cooling Tower Basin Mater X

X/X Soil samples are analyzed for the following:

pH; soluble Na, Ca, K, Mg; B; exchangeable Na, Ca, K, Mg; electrical conductivity; SO4=, N03, Cl F

C03, HC03, NH4+ and P04=.

Textural analysis is performed once as part of a baseline characterization for each monitoring site.

Native vegetation and crop samples are analyzed for Na, Ca, K, Mg and for as S04=,

N03-, Cl-,

F-and P04 The collected dustfall samples are analyzed for total suspended solids and 3

the most significant components of the cooling tower blowdown (and drift) as identified in Table 3.6-1 of the PVNGS ER-OL, Units 1-3.

Finally, cooling tower basin water is sampled and analyzed at least quar-terly for the same major constituents as the dustfall samples and identified in Table

3. 6-1 at the PVNGS ER-OL, Units 1-3, to confirm the composition of the drift (and blowdown).

As a minimum, these include:

Ca, Mg, Na, K, Cl

, N03-, S04=,

and Si.

Additionally, mi nor constituents are quantitatively assessed to the extent possible.

Interpretation of the aerial photography is conducted by qualified person-nel.

Areas of apparent vegetative stress are delineated, and a field inspection conducted to identify causal effects for all areas of apparent 2-9

stress.

If there are any environmental

changes, a

map is prepared which indicates those areas.

2.4 Data Review The reported data is examined by NUS for consistency.

Suspicious data may prompt a request for a repeat analysis of the sample(s).

Meteorological data are used to ascertain that the pattern of salt deposition is consistent with the prevailing winds, stability classes, and precipitation over the period of sampling.

Patterns of inconsistent

data, or locations with large differences in the paired samples may indicate that the locations are sub-ject to interferences or tampering.

Additional sampling or an alternate sampling location may be required for these locations.

Once the individual data have been

examined, timely summaries are prepared.

Data are compared for discernible differences between the control samples.

Seasonal and annual summaries are prepared and the data examined for cor-relations with meteorological conditions over the period.

Methods for demonstrating differences in the annual data include changes in the chloride to sodium ratios, and isopleths of annual concentrations.

The evaluation of the control and plant vicinity differences includes analyses for correlation between salt deposition, airborne concentration, and changes in soil and/or plant chemistry.

Detailed evaluation of changes in any of the three media (air, soil, plants) at one or more sampling locations are evaluated by appropriate statistical analyses.

2. 5

(}uality Assurance Program A comprehensive quality assuran'ce program is essential for the successful conduct of a good monitoring program.

The quality control measures designed into the program include:

o colocated samples at each sampling location to determine sample precision; o

an observation and data record for each sample; o

the checking of the algicide concentrati on as an 'indication of sample integrity for dustfall samples; o

sampling at a range of distances from the cooling towers to show the procedures are capable of detecting salt deposition and also for determining the limit of detection; o

detailed written procedures for all aspects of the program.

Written quality assurance procedures have been developed in accordance with 3

the quality assurance requirements of ANPP.

The laboratory quality assur-.

'nce programs provide the required quality assurance checks on the sample analyses at the laboratory.

An independent audit and inspection will be conducted to review the sampling methods and the techniques and records of the analytical laboratory.

2-10