Docket No. 50-335 FEB 13 8N Docket File Mr. J.
W. Williams, Jr.
Vice President Nuclear Energy Department Florida Power 8 Light Company P.
0.
Box 14000 Juno Beach, Florida 33408 ORB83 Rdg DEisenhut OELD EJordan
,DSells PMKreutzer ACRS (10)
P. L~+or
Dear Mr. Williams:
SUBJECT:
REANALYSIS OF REACTOR COOLANT PUMP SEIZED ROTOR AND LOSS OF ALL NON-EMERGENCY AC POWER As a result of several conference calls, you supplied some clarifying in-formation concerning the reactor coolant pump seized rotor and loss of all non-emergency AC power accidents.
In reviewing this information, several areas of apparent conflict have been identified.
These areas are covered in the enclosure to this letter and were telecopied to your staff on January 26 and February 2, 1984.
It is requested that you provide responses to these requests for clarifica-tion as early as possible in order for the staff to complete its review.
Our current schedule calls for the review to be completed by the Reactor System Branch by February 29, 1984.
If there are any questions, please contact the Project Manager, D. Sells (301) 491-9735.
The reporting and/or recordkeeping requirements contained in this letter affect fewer than ten respondents; therefore, OMB clearance is not required under P.L.96-511.
Sincerely,
Enclosure:
Request for Additional Information ORgnaI sIgned by:
James R. Miller, Chief Operating Reactors Branch 83 Division of Licensing cc:
See next page ORB P
er 2/
/84 0
D e s:dd 2/
/84
/
- DL M lier
/
/,84 84022i0294'840213 PDR ADOCK
'05000335-',':
PDR,'
I /I y
b II A'
g 1
li r