ML17300B174

From kanterella
Jump to navigation Jump to search
Forwards Proprietary Engineering Calculation 77-RCP-R01-008, Shaft Design Calculation, Per Request.Encl Withheld (Ref 10CFR2.790(b)(4))
ML17300B174
Person / Time
Site: Palo Verde  
Issue date: 12/31/1987
From: Van Brunt E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To: Licitra E
NRC
Shared Package
ML17300B175 List:
References
161-00726-EEVB, 161-726-EEVB, NUDOCS 8801120279
Download: ML17300B174 (14)


Text

REGULA Y INFORM*TION DISTR IBUTIO YBTEM (R'IDS) r~.

ACCESSION NBR: 8801120279 DOC. DATE: 87/12/31 NOTARIZED: NO'OCKET ¹ FACIL:STN-50-528 Palo Verde Nuclear Stationi Unit 1. *rizona Pub 1 i 05QOQ528 AUTH. NAME

  • UTHOR AFFILIATlON VAN BRUNTi E. E.

Arizona Nuclear Power ProJect (formerly Arizona Public Serv RECIP. NAME RECIPIENT AFFILIATION LICITRAiE. A.

NRC No Detailed Affi 1 iation Given

SUBJECT:

Forwards proprietary Eng ineer ing Calculation 77-RCP-R01-008'Shaft Design Calculationi" per request. Encl withheld (ref 10CFR2. 790(b ) (4) ).

DISTRIBUTION CODE:

PA01D COPIES RECEIVED: LTR ENCL SIZE:

TITLE: Proprietary Review Distribution-Operating Reactor NOTES: Standard i z d

p lant.

osooos~s i'pk)

REC IP IEN COP IES REC IP IENT COP IEB ID CODE/NAME LTTR PD5 LA 1

LICITRAiEjfVj/~j/>

3 INTERNAL: ACRS ~/2~~~~

~

6 AEOD/

AH +g.

1 G FILE Pfs 1

ENCL 1

3 6

1 1

ID CODE/NAME PD5 PD DAVIS' AEOD/DOA OGC/HDS1 LTTR ENCL 1

3 3

1 1

1 0

EXTERNAL:

LPDR NOTES:

1 0

NRC PDR 1

0 TOTAL NUMBER OF COPIES REQUIRED:

LTTR 21 ENCL 18

l gii

0 Arizona Nuclear Power Project P.O, BOX 52034

~

PHOENIX, ARIZONA85072-2034 December 31, 1987 161-00726-EEVB/JRP Docket Nos.

STN 50-528/529/530 U. S. Nuclear Regulatory Commission Washington, D.

C.

20555 Attention:

E. A. Licitra

Dear Mr. Licitra:

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Units 1, 2 and 3

Shaft Design Calculation Pile:

87-A-056-026 I

Enclosed please find one copy (Copy No.

000002) of Engineering Calculation No.

87-RCP-R01-008, "Shaft Design Calculation" as per your request.

Please note that this information is considered proprietary to CE an'd is being submitted with an affidavit in conformance with the provisions of 10CFR2.790(b)(4) of the Commission's regulations for withholding such informa-tion.

Should you have any questions, please call.

Very truly yours, z-c-v' E. E. Van Brunt, Jr.

Executive Vice President Prospect Director EEVB/JRP/cal Enclosure (Proprietary) cc:

G.

W. Knighton J.

B. Martin J.

R. Ball 880>'Saoa79 87Saal PDR ADOCN, 05000528 P 'DR

AFFIDAVIT PURSUANT TO 10 CFR 2.790 Combustion Engineering, Inc.

)

State of Connecticut

)

County of Hartford

)

SS.:

I, A. E. Scherer, depose and say that I am the Director, Nuclear Licensing, of Combustion Engineering, Inc., duly authorized to make this affidavit, and have reviewed or caused to have reviewed the information which is identified as proprietary and referenced in the paragraph immediately below. I am submitting this affidavit in conformance with the provisions of 10 CFR 2.790 of the Commission's regulations for withholding this information.

The information for which proprietary treatment is sought is contained in the following document:

"Shaft Design Calculation",

No. 77-RCP-R01-008, C-E KSB.,Pump. Company, Combustion Engineering, Inc., October 1978.

This document has been appropriately designated as proprietary.

I have personal knowledge of the criteria and procedures utilized by Combustion Engineering in designating information as a trade secret, privileged or as confidential commercial of financial information.

Pursuant to the provisions of paragraph (b) (4) of Section 2.790 of the Commission's regulations, the following is furnished for consideration by the Commission in determining whether the information sought to be withheld from public disclosure, included in the above referenced

document, should be withheld.

0 oA

1.

The information sought to be withheld from public disclosure are analysis methods for and results of reactor coolant pump shaft stress'calculations, which is owned and has been held in confidence by Combustion Engineering.

2.

The information consists of test data or other similar data concerning a

process, method or component, the application of which results in substantial competitive advantage to Combustion Engineering.

3.

The information is of a type customarily held in confidence by Combustion Engineering and not customarily disclosed to the public.

Combustion Engineering has a rational basis for determining the types of information customarily held in confidence by it and, in that connection, utilizes a system to determine when and whether to hold certain types of information in confidence.

The details of the aforementioned system were provided to the Nuclear Regulatory Commission via letter DP-537 from P.

M. Stern to Prank Schroeder dated December 2,

1974.

This system was applied in determining that the subject document herein are proprietary.

4.

The information is being transmitted to the Commission in confidence under the provisions of 10 CPR 2.790 with the understanding that it is to be received in confidence by the Commission.

5.

The information, to the best of my knowledge and belief, is not available in public sources, and any disclosure to third parties has been made pursuant to regulatory provisions or proprietary agreements which provide for maintenance of the information in confidence.

6.

Public disclosure of the information is likely to cause substantial harm to the competitive position of Combustion Engineering because:

a.

A similar product is manufactured and sold by major pressurized water reactor competitors of Combustion Engineering.

b.

Development of this information by C-E required hundreds of manhours and tens of thousands of dollars.

To the best of my knowledge and belief a competitor would have to undergo similar expense in generating equivalent information.

c.

In order to acquire such information, a competitor would also require considerable time and inconvenience to develop the reported analysis methods and results.

d.

The information required significant effort and expense to obtain the licensing approvals necessary for application of the information.

Avoidance of this expense would decrease a competitor's cost in applying the information and marketing the product to which the information is applicable.

e.

The information consists of analysis methods; for and results of reactor coolant pump shaft stress calculations, the application of which provides a competitive economic advantage.

The availability of such information to competitors would enable them to modify their product to better compete with Combustion Engineering, take marketing or other actions to improve their product's position or impair the position of Combustion Engineering's

product, and avoid developing similar data and analyses in support of their processes, methods or apparatus.

f.

In pricing Combustion Engineering's products and services, significant research, development, engineering, analytical, manufacturing, licensing, quality assurance and other costs and expenses must be included.

The ability of Combustion Engineering's competitors to utilize such

t fa h

information without similar expenditure of resources may enable them to sell at prices reflecting significantly lower costs.

g.

Use of the information by competitors in the international marketplace would increase their ability to market nuclear steam supply systems by reducing the costs associated with their technology development.

In addition, disclosure would have an adverse economic impact on Combustion Engineering's potential for obtaining or maintaining foreign licensees.

Further the deponent sayeth not.

A.

c erer Director Nuclear Licensing Sworn to before me

. ',=, this'<g day of ~g<~bp/

ling R C

A

+o re

'Notary'ublic

.--5USANNE SM}TH, QOTARY PUBLIC State of Connecticut fIlo. 74148 Commission Expires March 31, 1990

\\

~,~g a

<n 4

~,

4',

I

)(

f s

1$ Jll lw

0 Artzo~ a k4Jclear Power Project P.o. SOW PHOENIX. ARIZONA85072-2034 December 31, 1987 161-00726-EEVB/JRP Docket Nos.

STN 50-528/529/530 U. S. Nuclear Regulatory Commission Washington, D.

C.

20555 Attention:

E. A. Licitra

Dear Mr. Licitra:

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Units 1, 2 and 3

Shaft Design Calculation File:

87-A-056-026 Enclosed please find one copy (Copy No.

000002) of Engineering Calculation No.

87-RCP-R01-008, "Shaft Design Calculation" as per your request.

Please note that this information is considered proprietary to CE and is being submitted with an affidavit in conformance with the provisions of 10CFR2.790(b)(4) of the Commission's regulations for withholding such informa-tion.

Should you have any questions, please call.

Very truly yours, rgb~ S E. E. Van Brunt, Jr.

Executive Vice President Project Director EEVB/JRP/cal Enclosure (Proprietary) cc:

G.

W. Knighton J.

B. Martin J.

R. Ball