ML17299A626

From kanterella
Jump to navigation Jump to search
Confirms Installation & Qualification of Containment High Range Radiation Monitors & Primary Coolant Radiation Monitors,Per 10CFR50.49,License Condition 2.C(6) & Sser (NUREG-0857)
ML17299A626
Person / Time
Site: Palo Verde Arizona Public Service icon.png
Issue date: 09/27/1985
From: Van Brunt E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To: Knighton G
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0857, RTR-NUREG-857 ANPP-33590-EEVB, NUDOCS 8510010046
Download: ML17299A626 (6)


Text

REGULATO INFORMATION DISTRIBUTION TEM (RIDS)

ACCEQSS0$

NBR:8510010006 DOC,DATE: 85/09/27 NOTARIZED NO DOCKET; 0 FACK:STN-50 528 Palo Verde, Nuclear. Stationi Unit 1g Ar izona Publ i 05000528 AUTH NAME AUTHOR AFFILIATION VAN BRUNTrE.E ~

Arizona Nuclear-Power Project (formerly Arizona. Public-Serv RECIP ~ NAME:

REClPZENT AFFILIATION KNIG H T0 Ni G ~ l"I ~

L'icensing Br anch 3-

SUBJECT:

Confirms instal lation 8 qualification of containment>> high range radiation monitors L primary coolant radiation monitorsiper>> 10CFR50,09iLicensel Condition 2,C(6), L SSER L

(NUREG-0857).

DISTRIBUTION CODE::

AO<IBD COPIES'ECEIVED! L~TR

'NCL, SI2E:'

'ITLEi OR/Licensing. Submittal: Equipment'ualification 1

NOTES!Standardized plant ~

OL: 12/34/84 05000528 REC IP lENT ID CODE/NAME>>

NRR LB3 BC 12' COPIES" LTTR ENCL.

RECIPIENT ID CODE/NAME,:

LICITRAg E 01 COPIES LTTRi ENCL:

1 INTERNAL; ACRS ELD/HDS3 GC NRR/DE/EQB NR R/D S I'/AE 8 RGN5 15>>

12" 13>>

07 8

1.

l~

1 ~

1 ADM/LFMB ELD 'SHIELDS' NRR KARSCHgR NR R

1Q LE.

04 EXTERNAL; 24X NRC PDR>>

02'PDR NSIC 03>>

05" TOTAL'UMBER OF COPIES" REQUIRED: 'TTR 25 ENCL

II I

~

a

~

s I,

v N

tf

'I W ~

gi f-L I

M

Arizona Nuclear Power Project P.o. BOX 52034

~

PHOENIX, ARIZONA85022-2034 Director of Nuclear Reactor Regulation Attention:

Mr. George M. Knighton, Chief Licensing Branch No.

3

'ivision of Licensing U. S. Nuclear Regulatory Commission washington, D. C.

20555 September 27, 1985 ANPP-33590-EEVB/BJA

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Unit 1 Docket No.

STN 50-528, License No. NPF-41 PVNGS Unit 1 Environmental Qualification File:

85-056-026 G.l.01.10

References:

(1)

Letter from E. E.

Van Brunt, Jr.,

ANPP, to G.

W. Knighton,

NRC, dated September 10, 1984 (ANPP-30476).

Subject:

PVNGS Environmental Qualification Justification for Interim Operation.

(2)

NUREG-0857, Supplement No. 7, "Safety Evaluation Report Related to the Operation of Palo 'Verde Nuclear Generating Station, Units 1, 2, and 3," dated

December, 1984.

(3)

Letter from E. E. Van Brunt, Jr.,

ANPP, to G.

M. Knighton,

NRC, dated May 1, 1985 (ANPP-32541).

Subject:

PVNGS Environmental Qualification Justification for Continued Operation.

Dear Mr. Knighton:

Reference (1) submitted a Justification for Interim Operation (JIO) for PVNGS Unit 1 in order to complete the installation of environmentally qualified radiation monitors.

These two radiation monitors are the containment high-range radiation monitors.

Additionally, Reference (3) submitted a Justification for Continued Operation (JCO) for PVNGS Unit 1 in order to complete the installation of environmentally qualified radiation monitors.

These two radiation monitors are the primary coolant system radiation monitors.

Accords;ngly, by the issuance of the Unit 1 Operating License, the NRC Staff has iinposed license condition 2.C(6) for ANPP to complete the installation of environmentally qualified radiation monitors prior to November 30, 1985.

ANPP confirms that the installation of the radiation monitors has been completed and these monitors are now fully qualified for use at PVNGS in accordance with the provisions of 10CFR 50.49.

85~OOqoO~ 8Sm2 pDR ADocw onooo

G.

M. Knighton

, PVNGS Unit l Environmental Qualification ANPP-33590 Page 2

Xf you have any questions on this matter, please contact Mr. M. F. Quinn of my staff.

Very truly yours, E. E.

Van Brunt, Jr.

Executive Vice President Project Director EEVB/BJA/slh cc:

E. A. Licitra A. C. Gehr R. P.

Zimmerman

t,