REGULA NFORMATION DISTRIBUTIO

~

TEM (RIDS)

ACCFSSIOIH NBR;8505300100 DOC,DATE: 85/05/28 NOTARIZED'O DOCKET FACIL:STN"50-528 Palo Verde Nuclear Station~

Unit 1< Arizona Publi 05000528 AUTH BYNAME AUTHOR AFFILI ATXON VAN BRUNTiE ~ E.

Arizona Public Service Co, RECIP ~ NAME RECIPIENT AFFILIATION KNIGHTONiG ~ N ~

Licensing Branch 3

SUBJECT:

Confirms completion of actions taken to correct listed Suppl 1 to NUREG-0737~human engineering discrepancies re control room design review described in 801029 ltr~ License Condition 2 AC(19),(b) closede DISTRIBUTION CODE A003D COPIES RECEIVED: LTR J'NCL P

SIZE:

TITLE: OR/Licensing Submittal!

Suppl 1 to NUREG 0737(Generic Ltr 82 33)

NOTES:Standardized plant.

OL: 12/31/8A 05000528 RECIPIENT ID CODE/NAME NRR LB3. BC COPIES LTTR ENCL.

RECIPIENT ID CODE/NAME

'COPIES LTTR ENCL INTERNALS ADM/LFMB NRR PAULSONi5 N'RR/DHFS/PSRB'RR/DL/ORB5 NRR/DSI/ICSB NRR/DSI/

AB ES EXTERNAL: LPDR NSIC 1

2 5

1 1

1 IE/DEPER/EPB NRR/DHFS/HFEB NRR/DL/ORAB NRR/DSI/CPB NRR/DS I/METB NRR/DS I/RSB RGN5 NRC PDR 3

5 1

1 1

1 1

1.

1 1

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 35 ENCL 3

~

~

M

Arizona Nuclear Povver ProJect P.O. BOX 52034 o

PHOENIX, ARIZONA85072-2034 Director of Nuclear Reactor Regulation Attention:

Mr. George W. Knighton, Chief Licensing Branch No.

3 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D. C.

20555, ANPP-32741-EEVB/MAJ May 28, 1985

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Unit 1

Condition 2.(19)(b)

Supplement 1 to NUREG-0737=Human Engineering Discrepancies (HED's)

Docket No.

STN 50-528 (License No. NPF-34)

File:

85-056-026; G.1.01.10

Reference:

Letter to G.

W. Knighton, NRC, from E.E.

Van Brunt,Jr.,

APS, dated October 29, 1984 (ANPP-30986).

Subject:

Control Room Design Review.

Dear Mr. Knighton:

License Condition 2.C(19)(b) states:

"Prior to exceeding 5% of full power, APS shall implement actions to correct HED's A-3.1,

173, 151A,
152A, 154A,
158A, 161A,
163A, 164A,
159B, 165A,
166A, and 153A as described in its submittal of October 29, 1984."

In accordance with License Condition 2.C(19)(b)we hereby confirm completion of the actions taken to correct the subject HED's as described in our October 29, 1984 letter.

This completes the action items required to close out License Condition 2.C(19)(b).

If you have any questions, please call William guinn of, my staff at extension 4087.

Very truly yours, SS0SSO0>4O S505aat PDR

  • DOCK 05000528 F

PDR EEVB/MAJ/mkm cc:

A. C. Gehr E. Licitra R.

Zimmerman G. Fiorelli Executive Vice President Project Director

~0 G.

W. Knighton Human Engineering Discrepancies Page 2

ANPP - 32741 bcc:

D. B. Karner W. F. Quinn T. F.

Quan J.

W. Rowland LCTS Coordinator K.

W. Gross J.

N. Allen J.

R.

Bynum D. R. Canady

0. J. Zeringue G. Sanchez A. C. Rogers

oO

~I