ML17298C117

From kanterella
Jump to navigation Jump to search
Informs That All Reg Guide 1.97,Rev 2 post-accident Monitoring Instruments Either Fully Qualified for Use or Justification for Continued Safe Operation Provided.Review Conducted Per Re Environ Qualification
ML17298C117
Person / Time
Site: Palo Verde Arizona Public Service icon.png
Issue date: 05/10/1985
From: Van Brunt E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To: Knighton G
Office of Nuclear Reactor Regulation
References
RTR-REGGD-01.097, RTR-REGGD-1.097 ANPP-32610-EEVB, NUDOCS 8505130378
Download: ML17298C117 (5)


Text

REGULATO INFORMATION DISTRIBUTION STEM (RIDS)

ACCESSION NBR $ 85051303'78 DOC ~ DATE! 85/05/10 NOTARIZEDS NO DOCKET'ACIL:STN 50 528 Palo Verde Nuclear>> Stationi Unit 1E Arizona Publi 05000528 AUTH~ NAME' AUTHOR-AFFILIATION VAN BRUNTiE",E.

Arizona Public Service Co.

REC IP ~ NAME>>

RECIPIENT AFF ILLATION KNIGHTONgGoNs Licens)ng Branch 3

SUBJECT:

Informs that all Reg Guide 1 ~ 97iRev 2 post accident monitor ing instruments either fully qualified for use'r Just) fication for continued safe oper ation proyided Rev1ebl conducted

-per 8SQ501 ltr re environ qualification.

DISTRISUTION CODE>>

AOOSD COPIES RECEIVED:LTR. Q ENCL ~'IZE, TITLEc OR/Licensing Submittal i Equipment'ualification NOTES:Standardized plant".

OL'12/31/84 Q5000528 RECIPIENT ID CODE/NAME, NRR: LB3 BC 12",

INTERNAL; ACRS

'15 ELD/HDS3 12!

GC 13 NRR/DE/EQB 07 NRR/DS I'/AEB RGN5 COPIES LTTR ENCL'ECIPIENT" ID CODE/NAME" LICITRAiE>>

01 ADM/LFMB ELD SHIELDS g N NRR KARSCHiR DIR 14 REG-FIL 04 COPIES LTTR ENCL 1

1 1

1 1

EXTERNAL! LPDR NSIC 03>>

05.

NRC PDR 02>>

TOTAL NUMBER OF COPIES REQUIRED'= LTTR 20 ENCL

'0 1

b f II ll II) g "II, k

II "fb W bf 0

I' II

~

b qlli i

~ ,

rb W

'ff4

) ~

f (

=1 ff (Ibif

~

fl

'il ff',

W I

1ri

' f')

r'lfi19I44 W feM f

')WW t l' f% '+

"WWPf fW(i f

AQ W4 f MMff Qf I

%M'1 M>b ~

f ~elf f fWfb, f'f,ff~fM4 V) 4 g.I IW W W fWW M f 4 I 1

~WY<< f

,Wf,j; f fbf4W

<<0 I' Wffb I

~

t Wbg WW f (I f r'f 1lW'l Wf 'if

~ ffflf fig i+ 'btlf' If/

I 'Aln l Rhlfr

'44 I",fW W

"f if 1

'4 ll,J

<J'lf WR,I i i g

)

M )

Ii M'I g

1 f

fk C

l

,f M 'I

,ffb> W'4 tf'I ll W

Wp lf I IW,>>I V, ]Sr "

M W

W,

Arizona Nuclear Povver Project P,o. BOX 52034 o

PHOENIX, ARIZONA85072-2034 Director of Nuclear Reactor Regulation Attention:

Mr. George W. Knighton, Chief Licensing Branch No. 3 Division of Licensing U.S. Nuclear Regulatory Commission Washington, D.C.

20555 ANPP-32610-EEVB/BJA Hay 10, 1985

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Unit 1 Docket No.

STN 50-528, License No. NPF-34 Environmental Qualification File:

85-056-026 G.1.01.10

References:

(1)

Letter from E. E.

Van Brunt, Jr.,

ANPP, to G.

W. Knighton, NRC, dated May 1, 1985 (ANPP-32541);

Subject:

PVNGS Environmental Qualification.

(2)

Letter from E. E.

Van Brunt, Jr.,

ANPP, to G.

W. Knighton, NRC, dated December 7,

1984 (ANPP-31379);

Subject:

PVNGS Environmental Qualification.

(3)

Letter from E. E.

Van Brunt, Jr.,

ANPP, to G.

W. Knighton, NRC, dated September 10, 1984 (ANPP-30476);

Subject:

PVNGS Environmental Qualification.

(4)

Letter from E. E.

Van Brunt, Jr.,

ANPP, to G.

W. Knighton, NRC, dated December 3, 1984 (ANPP-31297);

Subject:

PVNGS Environmental Qualification.

Dear Mr. Knighton:

A telecon was held on May 9, 1985 between ANPP and the NRC staff to discuss the Justification for Continued safe Operation (JCO) for the primary coolant system radiation monitors.

This JCO was submitted to the NRC by Reference (1).

Additionally, Reference (1) stated that ANPP would conduct a review of the qualification status of the instrumentation that is used to meet the guidance of Regulatory Guide 1.97, Revision 2.

The purpose of this submittal is to provide the results of the review.

The review of the qualification status of the post accident monitoring instrumentation that is used to meet the guidance of Regulatory Guide 1.97, Rev.

2 has been completed.

ANPP has concluded that all of the Regulatory Guide 1.97 instruments are either fully qualified for use at PVNGS or a JCO/JIO has been provided to the NRC staff.

Equipment Qualification JCO's (JIO's) that involve Regulatory Guide 1.97 equipment have been submitted to the NRC staff in the letters of References (1) through (4).

8505i30378 850510 PDR ADOCK 05000528 F

PDR ok<

(o

~

~c george N. Knighnon Environmental Qualification ANPP-32610 Page 2

0 If you have any questions on this matter, please contact Mr. M. F. Quinn of my staff.

Very truly your E. E.

Van Brunt, Jr.

Executive Vice President Project Director EEVB/BJA/slh CC:

E.

A. Licitra H. Garg R. LaGrange R.

P.

Zimmerman A. C. Gehr