I REGULATOR NFORMATION DISTRIBUTION S "TEM (RIDS) la Ac'CESSION NBR; 8504250274 DOC ~ DATE: 85/04/19 NOTARIZED; NO FACIL:STN-50 528 Palo Verde Nuclear Stations Unit ii Arizona Publi AUTH BYNAME AUTHOR AFFILIATION VAN BRUNTiE.E ~

Ar izona Publ ic Service Co.

RECIP ~ NAME RECIPIENT AFFILIATION THOMPSON~H ~ L, Division of Licensing DOCKET 0

05000528

SUBJECT:

Forwards remaining responses to NRC 840529 requests for addi info re operating shift advisors. Info re train)ng program~

medical qualification requirements 8, oral L written exams encl'ISTRIBUTION CODE:

M003D COPIES RECEIVED:LTR ENCL'ITLE:

Oper ator Requalification Program NOTES:Standardized plant.

OL e 12/31/84 05000528 RECIPIENT ID CODE/NAME NRR LB3 Bc INTERNAL: ACRS 08 NRR/DHFS/OLB 01

RGN5, COPIES LTTR ENCL 1

1 10 1O 2

2 1

1 RECIPIENT ID CODE/NAME LICITRAg E NRR/0

/LQB G

04 COPIES LTTR ENCL 1 ~

1 1

1 1

EXTERNAL: LPDR NSIC 03 05 1

1 1

1 NRC PDR 02 TOTAL NUMBER OF COPIES REuUIRED:

LTTR 2O ENCL 2O

r

~

t Il r

~ s h

n sy I

1

) $

4

)f l1 f

F 4

. w y ~

}<

4

]II e

l l

k

Arizona Nuclear Povver Project P.o. BOX 52034 e

PHOENIX, ARIZONA85072-2034 Mr. H. L. Thompson, Director ANPP-32452-EEVB/MFQ Division of Licensing April 19, 1985 U.S. Nuclear Regulatory Commission Phillips Building 7920 Norfolk Avenue

Bethesda, MD 20814

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Unit 1 Docket No.

STN 50-528, License No. NPF-34 Operating Shift Staffing for PVNGS; Shift Advisors for Unit 1 File: 85-001-702 85-056-026

References:

(1) Letter from D. G. Eisenhut, NRC, to E.

dated May 29, 1984;

Subject:

Operating Verde Plant.

(2) Letter from E. E.

Van Brunt, Jr. to H.

32198),

dated March 21, 1985;

Subject:

for PVNGS; Shift Advisors for Unit 1.

E.

Van Brunt, Jr.,

APS, Shift Staffing for Palo L. Thompson,
NRC, (ANPP-Operating Shift Staffing

Dear Mr. Thompson:

Enclosure 2 of the NRC letter dated May 29, 1984 (Reference

1) provided 8

NRC information requests to be provided if shift advisors were to be used on PVNGS (Refer to Attachment A).

Our responses to the NRC requests Nos.

1 through 3 were previously provided in our March 21, 1985 letter (Reference 2).

The purpose of this letter is to provide the remaining responses to NRC requests Nos.

4 through 8.

The responses to NRC requests Nos.

4 through 8 are hereby provided in Attachment B.

Supplemental information for responses 4 through 8 are provided in Attachments C and D.

If you should have any further questions or require additional information, please call Mr. Todd Bloom of my staff at (602) 943-7200, extension 4159.

Very truly ours EEVB/TJB/mb Attachments:

A,B cc:

A. C. Gehr E.

A. Licitra R. P.

Zimmerman R. J.

Pate L. P. Crocker (w/a A,B)

(w/a A,B)

(w/a A,B)

(w/a A,B)

(w/a A through D)

E. E.

Van Brunt, Jr.

Executive Vice President Project Director 8504250274 850419 PDR ADDCK 05000528 V

PDR

ANPB-32452 ATTACHMENT A INFORMATION RE UIRED REGARDING SHIFT ADVISORS l.

A resume of each shift advisor which highlights his previous operating experience.

2.

A copy of the procedure which describes the duties and authority of the shift advisors and the working relationships between the advisors and the operating shift personnel.

3.

A copy of the training program presented to the shift advisors to assure they have adequate knowledge of plant specific matters to properly perform their duties.

4.

A copy of the written examination administered to the shift advisors and the results of the examination, if available.

5.

A description of, and copies of notes'regarding, the oral examination adminis-tered to the shift advisors.

6.

A description of the training program presented to the operating shift crews to assure that they understand the role of the shift advisors.

7.

A statement regarding the medical qualification requirements for the shift advisors.

8.

A description of the procedures that will be used to evaluate the performance of the shift advisors during plant start-up.

ANPR-32452 ATTACHMENT B 4.

A copy of the written examination administered to the shift advisors and the results of the examination, if available.

ANPP RESPONSE:

As identified in Attachment 3 to Reference 2 of the cover letter, three weekly written examinations are being administered.

The written examination results were as follows:

Mr. Jose Garza Mr. Lloyd Briner Week One 97/100 93/100 Week Two 91.9/100 95.2/100 Week Three 89.2/100 91.8/100 Attachment C provides one copy of each examination plus one copy of each examination with an answer key.

NRC RE UEST:

5.

A description of, and copies of notes regarding, the oral examination administered to the shift advisors.

ANPP RESPONSE:

As identified in Reference 2 of the cover letter, the Shift Advisor 'Training Program consists of weekly written examinations (total of three) and several simulator evaluations.

Based on the foregoing, no oral examination i's planned for inclusion in'the training program.

However, we have provided a copy of the Shift Advisor PVNGS Simulator Evaluation Report Form as Attachment D for your information.

+

r(

k

Attachment B

ANPP-32452 Page 2

NRC RE UEST:

6.

A description of the training program presented to the operating shift crews to assure that they understand the role of the shift advisors.

ANPP RESPONSE:

The training program for the operating shift crews is currently being conducted during Session 3 of the Requalification Program and consists of the following:

(1) Each operator will read the Operating Department Guideline (ODG-37),

"Responsibilities and Duties of the Shift Advisor" which was provided to you as Attachment 2 of Reference 2 of the cover letter.

(2) Upper Level PVNGS Operations Management will present their views on the use of shift advisors to the operating crews.

(3)

A question and answer session will be provided for the operators by upper Operations Management to discuss any questions/concerns regarding this topic.

This training will be completed prior to initial criticality for all currently Licensed Operators.

The training for the shift crew which will utilize the shift advisor has been completed and documented on briefing forms.

l NRC RE UEST:

7.

A statement regarding the medical qualification requirements for the shift advisors.

ANPP RESPONSE:

As noted in Reference 2 of the cover letter, both shift advisor candidates are currently licensed operators at San Onofre Nuclear Generating Station (SONGS) and as such, they have provided the required medical information to the NRC pursuant to 10 CFR 55.33(a)(6).

In addition, any significant changes in their physical condition must be reported to the NRC by SONGS in accordance with 10 CFR 55.11(a)(1).

Therefore, we believe that appro-priate medical qualification requirements will be maintained during their involvement at PVNGS.

~

iv

'l t

P

A'ttachment B

ANPP-32452 Page 3

NRC RE UEST:

8.

A description of the procedures that will be used to evaluate the performance of the shift advisors during plant start-up.

ANPP RESPONSE:

Based upon the fact that the two shift advisor candidates are previously licensed operators, will have successfully completed the PVNGS Shift Advisor Training Course, and are to be used in an advisory capacity rather than in a performance based position, it has been determined that no performance evaluations will be required beyond those necessary to demonstrate initial qualification for the position.