ML17298C041

From kanterella
Jump to navigation Jump to search
Informs That Emergency Operating Procedures Revised to Incorporate Inadequate Core Cooling Instrumentation Per Rev 2 to CEN-152, Emergency Procedure Guidelines & Sser 6
ML17298C041
Person / Time
Site: Palo Verde  Arizona Public Service icon.png
Issue date: 04/15/1985
From: Van Brunt E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To: Knighton G
Office of Nuclear Reactor Regulation
References
ANPP-32400-EEVB, NUDOCS 8504170391
Download: ML17298C041 (5)


Text

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

A&CEO%ION NOR:8500170501 %DOC,DATE: 85/00/15 NOTARD: NO DOCKET'

. FACIL:STN-50-528 Palo Verde, Nuclear Stationi Unit 1E Arizona Publi 0500052S STN-50-529 Palo Verde Nuclear Station< Unit 2E Arizona Publi 05000529 STN-50-530 Palo Verde Nuclear Stations Unit 3i Ar izona Publi 05000530 AUTH, NAME AUTHOR AFFILIATION VAN BRUNTEE ~ ED Arizona Public Service Co.

REC IP. NAME: RECIPIENT AFFILIATION KNIGHTONE G ~ 1i ~ Licensing Branch 3<<

SUBJECT:

Informs that emergency operating procedures revised to incorporate inadequate'one cooling instrumentation per Rev 2 to CEN 152'Emergency Procedure Guidelines" 8 SSER 6 ~

n DISTRIBUTION CODE': B02'1D COPIES RECEIVED:LTR ENCL SIZE0

.T'ITLE: OR/Licensing Submittal! Combined General Distribution NOTES:Standardized plant ~ 05000528 OL: 12/31/84 Standardized plant. 05000529-Standardized plant=. 05000530 RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME'RR LTTR ENCL ID CODE/NAME LTTR ENCL LB3. BC 05 1 NRR LB3 LA 1 0 LICITRAEE 01 1 1 INTERNAL; ACRS 29 8 8 ADfl/LFMB 1 0 ELD/HDS3 1 0 NRR/DE/CEB 09 1 1 NRR/DE/MTEB 1 1 NRR/OHFS DEPY12 1 1.

NRR/DHFS/HF EB 1 6 1 1 NRR/DHFS/LGB 1 1 NRR/DL DIR 1 0 NRR/DL/OR/8 1 0 NRR/DL/SSPB 0 NRR/DS I/AORS 1 0 NRR/DSI /AEB 28 1 1 NRR/DS I'/CPP 11 1 NRR/DSI/CSB 10. 1 NRR/DS I/ICSB 18 1 1 NRR/DSI'/ME'TB 1 SB 21 1 1 NRR/DS I /RS0 25- 1 ~

1 REG ILE 04 1 1 RGN5 1' RM /MIB 1 0 EXTERNAL: LPDR 03 1 1 NRC PDR 02 1 1 NSIC 06 1 1 PNL GRUELER 1 1 TOTAL NUMBER OF COPIES REQUIRED: LTTR 36 ENCl 28

l I Il

Arizona Nuclear Povver Project P.o. BOX 52034 o PHOENIX, ARIZONA85072-2034 ANPP-32400/EEVB)WFQ Director of Nuclear React or Regulation April 15, 1985 Attention: Mr. George W. Knxghton, Chief Licensing Branch No. 3 Division of Licensing U.S. Nuclear Regulatory Commission Washington, D.C. 20555

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Units 1, 2, and 3 Response to License Condition 2.C.(8)

Revise Emergency Operating Procedures.

Docket Nos. STN 50-528(License No. NPF-34)/529/530 File: 85-056-026 G.1.01.10

'H

References:

(1) Safety Evaluation Report related to the Operation of Palo Verde Nuclear Generating Station Units 1, 2, and 3, Supplement 6, section 22.2(II.F.2), dated October 1984.

(2) CEN-152, Revision 2, "Combustion Eng'ineering Emer'gency Procedure Guidelines," dated May 1984.

(3) Letter to D. G. Eisenhut, NRC, from R. K. Wells, GEOG, dated November 26, 1984.

Subject:

Transmittal of Appendix A to CEN-152, Revision 02.

Dear Mr. Knighton:

The purpose of this letter is to inform the staff that the PVNGS Emergency Operating Procedures (EOPs) have been revised to incorporate the Inadequate Core Cooling Instru-mentation (ICCI) in accordance with CEN-152, Revision 02, "Emergency Procedure Guide-lines." The staff had approved the use of t'.he CEN-152, Revision 02 ICCI information at PVNGS provided that the staff's comments on pages 22-8 and 22-9 of Reference (1) were addressed or incorporated into the PVNGS EOPs. Since the issuance of Reference (1) the staff's comments on pages 22-8 and 22-9 have been addressed by the Combustion Engineering Owners Group per the submittal of Reference (3). Reference (3) is Appendix A to CEN-152, Revision 02 and is attached to this letter as our response to the staff's comments found on the above subject pages of Reference (1).

We believe that this information being submitted, sufficiently satisfies .the require-ments of Item 3 (page'2-9) of Reference (1) and the PVNGS Unit 1 License Condition 2.C.(8).

If you require any additional information or have any questions, please contact William Quinn of my staff.

Very truly u s, 8504i 7039i 8504i5 PDR ADOCK 05000528 F t QJLS PDR E. E. Van Brunt, Jr.

Executive Vice President Project Director EEVB/MAJ/mb Attachment

51r. George M. Knighton 0 Response to License Condition 2.C.(8)

Revise Emergency Operating Procedures ANPP- 324OO Page 2 cc: A. C. Gehr w/a E. A. Licitra w/a R. P. Zimmerman w/a

0 0 lq h