REGULATORY NFORMATION DISTRIBUTION SY EM (RIDS)

ACCESSION'BR 80 1 23 1 0305',

DOC>> DATE 80/1 2/2 1 NOTARIZED ~

~.YES, DOCKET'AOIL:STN"50>>528 Palo Verde-Nuclear Station~

Unit li Arjzona Publi 05000528 STN 50>>529 Palo Verde Nuclear Station) Unit 2g Arizona Publi 05000529 STN-50 530 Palo Verde Nuclear Station< Unit 3~ Arizona Publi 05000530

'AUTH',NAME". AUTHOR AFFILIATION VAN, BRUNTiE ~ E, Arizona Public 'Ser vice Co.

RECIP ~ NAME>>

RECIPIENT" AFFILIATION KNIGHTON,G ~,

Licensing Branch 3

SUBJECT:

.'Conf)rms that corrective, action ~to matlidrain plugs 8

terminal blocks in Limitorque'a)ve motor actuator s completed w/except)ons.noted in attachment, Justifications for~ interim operation encl.

DISTRIBUTION CODE; A008D COPIES ".RECEIVED:LTR

'NCL SI Eo TITLE: OR/Licensing Submittal'"Equipment" Qualification NOTES:Standardized plant.

Standardized plant.

Standardized plant ~

05000528 05000529 05000530 RECIPIENT'D CODE/NAME)

NRR LB3~ BC 12" INTERNAL: ACRS 15 ELD/HDS3 12 NRR KARSCHrR NRR/DL DIR 10 NRR/D S I'/AE 8 RGN5 COPIES LTTR ENCL 1

0

,8 8

1 1

1 1

1 1

1 RECIPIENT ID CODE/NAME LICITRA g E"-

01 ADM/LFMB GC 13 NRR/DE/EQB 07 N

AB 06 0Q COPIES LTTR~ ENCL.

1 1

1 0,

1 1

2" 2

1 1

1 1

EXTERNAL>> LPDR NSIC 03 05 1-1 1

1 NRC PDR NTIS 02'1=

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 25 ENCL 23

a l

it I l

l r

f ti>wt I

~

lt

~

I

~

tl I'

$ r I

a

~ fit

Arizona Public Service Company ANPP-31554-EEVB/NFQ December 21, 1984 Director of Nuclear Reactor Regulation Attention:

Mr. George Knighton, Chief Licensing Branch No.

3 Division of Licensing U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Units 1, 2 and 3

Docket Nos. STN-50-528/529/530 Equipment Qualification (Limitorque Valves)

File:

84-056-026; G.1.01.10

Reference:

Letter from E.E.

Van Brunt, Jr.,

APS, to G.W. Knighton,

NRC, dated December 13,
1984, (ANPP-31460);

Subject:

Equipment Qualification.

Dear Mr. Knighton:

Attachment 2 of the reference letter provided our status regarding the qualification of Limitorque valve operators and stated that the-corrective action to the material, drain plugs, and terminal blocks in the Limitorque VMA's will be completed prior to fuel load.

This letter confirms that the corrective action to the material, drain plugs and terminal blocks in the Limitorque VMA's has been completed with the exceptions noted in Attachment 1.

Attachment 1 contains justifications for interim operation for each item which is not completed as of this date.

If you have any questions, please contact me.

Very truly yours, EEVBJr/WFQ/no Attachments E. E.

Van Brunt, Jr.

APS Vice President Nuclear Production ANPP Project Director cc:

E. A. Licitra A. C. Gehr R.

P.

Zimmerman 84i23i0345 84i22i PDR ADOCK 05000528 A

PDR L

t

~

'I

ANPP 31554 STATE OF ARIZONA

)

) ss.

COUNTY OF MARICOPA)

I, Bryant F. Godwin, represent that I am Manager, Nuclear Records Management of Arizona Public Service Company, that the foregoing document has been signed by me on behalf of Arizona Public Service Company with full authority to do so, that I have read such document and know its contents, and that to the best of my knowledge and belief, the statements made therein are true.

yant F. Godwin Sworn to before me this Z1 day of

,1984.

My Commission Expires:

'y Commfsston Fxptres Mov. $2, 19SS Notary Public

~J>,'>P

)

/',

4<) f"'I i)) 'p) l

/gi)Q)C) >

1

4 E

~ ~J e

~a Ps

~

t ~

50

George W. Knighton fquipment Qualification (Limitorque Valves)

ANPP-31554 Page 2

bcc:

T.G.

D.B.

W.E.

A.C.

J.R.

O.J.

P.L.

J.T.

T.F.

M.F.

K.W.

S.R.

K.f.

E.J.

B.F.

W.H.

W.G.

S.H.

C.F.

M.F.

LCTS Woods Karner Ide Rogers Bynum Zeringue Brandjes Barrow Quan Hodge Gross Frost Jones Gouvier Godwin l

i tI

"'Environmental Designations (FSAR Section 3.11)

Components Inside Containment - The temperature,

pressure, humidit and che environment inside containment after a I.OCA or 1)SLB

[E I II Components inside containment which are required ft d

a er a esign basis LOCA.

Components outside containment.

'