ML17298B723

From kanterella
Jump to navigation Jump to search
Confirms That Required Corrective Actions Re Environ Qualification of Limitorque Valve Actuators Complete & Justifications for Interim Operation Provided in No Longer Applicable
ML17298B723
Person / Time
Site: Palo Verde  
Issue date: 12/26/1984
From: Van Brunt E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To: Knighton G
Office of Nuclear Reactor Regulation
References
ANPP-31571-WFQ, NUDOCS 8412280044
Download: ML17298B723 (8)


Text

REGULATORY INFORMATION OISTR~UTION SYOrYEH (RIOS)

ACCESSION NBR: 8012280044 DOC ~ DATE: 84/12/26 NOTARI'ZED:

YES DOCKET FACIL:STN"50-528 Palo Verde Nuclear Stationi Unit 1E Arizona Publi 05000528 STN 50-529 Palo Verde Nuclear Station~

Unit 2, Arizona Publi 05000529 STN-50-530 Palo Verde Nuclear Station~

Unit 3, Arizona Publi 05000530 AUTH,NAME AUTHOR AFFILIATION VAN BRUNTrE,E ~

Arizona Public Set vice Co ~

REC IP ~ NAME REC IPIENT AFFILIATION KNIGHTONg G ~ N ~

Licensing Branch 3

SUBJECT:

Confirms that required corrective actions re environ qualification of Limitorque valve actuators complete 8,

Justifications for interim operation provided in 801221 ltr no longer applicable, DISTRIBUTION CODE:

B001D COPIES RECEIVED:LTR ENCL SIZE:

TITLE; Licensing Submittal:

PSAR/FSAR Amdts 8, Related or respondence NOTES:Standardized plant

~

Standardized plant ~

Standardized plant ~

05000528 05000529 05000530 RECIPIENT ID CODE/NAME NRR/DL/ADL NRR LB3 LA INTERNAL: ACRS ll ELD/HDS3 IE/DEPER/EPB 36 NRR ROE'pM,L NRR/DE/CEB 11 NRR/DE/EQB 13 NRR/DE/MEB 18 NRR/DE/SAB 24 NRR/DHFS/HFEBOO NRR/DHFS/PSRB NRR/DS I/AEB 26 NRR/DS I/CP8 10.

NRR/DSI/ICSB 16 NRR/DSI/PS B

19 NRR/DSI/RSB 23 RGN5 EXTERNAl: BNL(AMDTS ONLV)

FEMA REP DIV 39 NRC PDR 02'TIS COPIES LTTR ENC 1

1 6

1 1

1 2'

1 1

1 1

1 1

1i.

3 RECIPIENT ID CODE/NAME NRR LB3 BC'I C I TRA g E 01 ADM/LFMB IE FILE'E/DQASIP/QAB21 NRR/DE/AEAB NRR/DE/EHEB NRR/DE/GB 28 NRR/DE/MTEB 17 NRR/DE/SGEB 25 NRR/DHFS/LQB 32'RR/DL/SSPB NRR/DS I/ASB NRR/DS I/CSB 09 NRR/DS I/METB 12 NRR/D

/RAB 22 0Q RM/DDAMI/MI8 DMB/DSS (AMDTS)

LPDR 03 NSIC 05 Pf4L GRUELtR COPIES LTTR ENCL 1

1 TOTAL NUMBER OF COPIES REQUIRED:

LTTR 53 ENCL

s 9

il

)

E

Arizona Public Service Company Director of Nuclear Reactor Regulation Attention:

Mr. George W. Knighton, Chief Licensing Branch No.

3 Division of Licensing U.S. Nuclear Regulatory Commission Washington, D.C.

20555 December 26, 1984 ANPP-31571 WFQ/TFQ

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Units 1, 2 and 3

Docket Nos. -STN-50-528/529/530 Equipment Qualification (Limitorque Valves)

File: 84-056-026; G.1.01.10

Reference:

Letter from E.E.

Van Brunt, Jr.,

APS, to G.W. Knighton,

NRC, dated December 21, 1984 (ANPP-31554);

Subject:

Equipment Qualification.

Dear Mr. Knighton:

The referenced letter provided the status of corrective actions required to assure environmental qualification of Limitorque valve actuators.

At the writing of the referenced letter, APS stated that not all of the required corrective actions would be made prior to fuel load of PVNGS Unit 1, and provided justifications for interim operation for those items.

APS hereby, confirms that the required corrective actions to the Limitorque valve actuators have been completed and the JIO's provided in the referenced letter are no longer applicable.

Please contact Mr. W.F. Quinn of my staff if you have any questions on this matter.

EEVBJr/TFQ/ho, cc:

E. A. Licitra A. C. Gehr R.

P.

Zimmerman Very truly yours, E. E.

Van Brunt, Jr.

APS Vice President Nuclear Production ANPP Project Director p8~4lg280Py4 8

ADQC~ p50005p t DR

A C

December 26, 1984 ANPP-31571 STATE OF ARIZONA

)

) ss.

COUNTY OF hfARICOPA)

I, Edwin E.

Van Brunt, Jr.,

represent that I am Vice President, Nuclear Production of Arizona Public Service

Company, that the foregoing document has been signed by me on behalf of Arizona Public Service Company with full authority to do so, that I have read such document and know its
contents, and that to the best of my knowledge and belief, the statements made therein are true.

Edwin E.

Van Brunt, Jr.

Sworn to,bedore me thin~day ot 1984.

Notary Public My Commission Expires:

eely Cominlssion Expires April 6, 1987

gl i'Q'~e'

~ (4 o,kl' p

t Pgf Jay l

Mr. George W. Knig~n Equi pment gu al ificati on ANPP-31571 Page 2

lit ii 1

(Limitorque Val ves) bcc':

T.G.

D.B.

W.E.

A.C.

J.R.

O.J.

P.L.

J.T.

M.F.

K.W.

S.R.

K.E.

E.J.

W.H.

W.G.

S.H.

C.F.

M.F.

LCTS Woods Karner Ide Rogers Bynum Zeringue Brandjes Barrow Hodge Gross Frost Jones Gouvier Wilson Bingham

Shepherd, Ferguson Barnoski Coordinator

0 tf ll

~,

t