Submits Info Re Deletion of FSAR Design Criteria to Slope Resin Lines Where Practical,Per 841210 Request.Sys Ability to Purge Resins Uneffected by Slope of Lines.Lines Sloped to Facilitate Drainage W/O Tee Fittings
ML17298B686
Person / Time
Site: Palo Verde  
Issue date: 12/17/1984
From: Van Brunt E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To: Knighton G
Office of Nuclear Reactor Regulation
References
ANPP-31494-WFQ, NUDOCS 8412200298
Download: ML17298B686 (8)


Text

REGULATORY

%FORMATION DISTRIBUTION S EM (RIDS)

ACCESSION NBR;8412200298 DOC ~ DATE: 84/12/17 NOTARIZED:, YES DOCKET ¹ FACIL:STN-50-528 Palo Verde Nuclear Station~

Unit ig Arizona Publi 05000528 STN-50-529 Palo Verde Nuclear Stations Unit 2~ Arizona Publi 05000529 STN-50-530 Palo Verde Nuclear Station~

Unit 3~ Arizona Publi 05000530 AUTH INANE AUTHOR AFFILIATION VAN BRUNTiE ~ E.

Arizona Public Service Co.

RECIP ~ NAME RECIPIENT AFFILIATION KNIGHTON I G ~ 'I'f ~

Licensing Branch 3

SUBJECT:

Submits info re deletion of FSAR design resin lines where practical<per 841210 r

to purge resins uneffected by slope of I

facilitate drainage w/o tee fittings.

DISTRIBUTION CODE:

8001D COPIES'ECEIVED:LTR TITLE: Licensing Submi ttel:

PSAR/FSAR Amdts 8,

Re 1

NOTES:Standardized plant.

Standardized plant.

Standardized plant>

criteria to slope equest~Sys ability ines>Lines sloped to ENCL SIZE:

ated Correspondence 05000528 05000529 05000530 RECIPIENT ID CODE/NAME NRR/OL/ADL NRR LB3 LA INTERNAL: ACRS ELO/HDS3 IE/DEPER/EPB 36 IE/OQASIP/QAB2f NRR/DE/AEAB NRR/OE/EHEB NRR/DE/GB 28 NRR/DE/MTEB 17 NRR/OE/SGEB 25 ERR/DHFS/LQB 32" NRR/DL/SSPB NRR/DSI/ASB NRR/DSI/CSB 09 NRR/DSI/METB 12',

NRR SI/RAB 22 REG F I 04

/MIB EXTERNAL: BNL(AMOTS ONLY)

FEMA REP DIV 39 NRC PDR 02'TIS COPIES LTTR ENCL 1

0 0

6 6

1 0

1 1

1 1

1 0

1 1

2 2

1 1

1 1

1 1

1 0

1 1

1 1

1 1

1 1

1 1

0 1

1 1

1 1

1 1.

1 RECIPIENT ID CODE/NAME NRR LB3 BC LICITRAg E 01 ADM/LFMB IE FILE IE/DEPER/IRB 35 NRR ROEgM ~ L NRR/DE/CEB 11 NRR/DE/EQB 13-NRR/DE/MEB 18 NRR/DE/SAB 24 NRR/DHFS/HFEB40 NRR/DHFS/PSRB NRR/DSI/AEB 26 NRR/DS I/CPB 10 NRR/DSI/ICSB 16'RR/DSI/PSB19 NRR/DSI/RS8 23 RGN5 DMB/DSS (AMOTS)

LPDR 03 NSIC 05 PAL GRUELiR COPIES LTTR ENCL.

1 0

1 1

0 1

1 1

1 1

1 1

1 2

2 1

1 1

1 1

l.

1 1

1 1

1 1

1 1

1 1

1 1

3 1

1 1

1 1

1 1

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 54 ENCL 46 C

0 fl

~

" 'N n

l f

~ T

~

~

~

C Nff I, '>N)f

~

"N )r f R

m

~4t

, ~

w f

N W,t N

t h

~

w i,i I

M

, f N

I NI)lf>>)

<<> I <<)

N' 1II y l

Arizona Public Service Company December 17, 1984 ANPP-3]494>>WFQ/TFQ Director of Nuclear Reactor Regulation Mr. George W. Knighton, Chief Licensing Branch No.

3 Division of Licensing U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Units 1, 2 and 3

Docket Nos.

STN 50-528/529/530 PVNGS FSAR Update Spent Resin Piping Layout File:

84-056-026 G.1.01.10 84-019-026 D.4.33.2

Reference:

Letter from E.

E.

Van Brunt, Jr.,

APS, to G.

W. Knighton,

NRC, dated December 10, 1984 (ANPP-31397)

Subject:

PVNGS FSAR Update Radiation Protection Design Features Dear Mr.

Knighton.'s a result of discussion with your staff regarding the referenced

letter, additional information is being provided to explain and )ustify the deletion of design criteria to slope spent resin lines where practical.

As described in FSAR Section 11.4, spent resins are transferred by

pumped, closed
circuit, sluicing process:

Spent resins are not transferred by gravity.

The closed loop transfer uses Johnson screens and strainers to accumulate resins in the receiving tank.

The resin free water is then used to continue the sluicing operation.

This process is used to purge the resin lines.

Thus, the slope of the line has little if any effect upon the ability of the system to purge resins to the receiving tank.

Since resin transfer is an infrequent

process, the lines were sloped to facilitate drainage without requiring the use of tee fittings for low point drains.

Such tees could con-stitute a resin trap.

For those horizontal lines that were not sloped, it was either impractical to slope them due to design or construction interferences, or they were able to be drained without the use of a tee fitting (e.g.,

the line routing included a vertical drop).

Thus, the description in the FSAR is being deleted to avoid future confusion over the necessity and practicality of sloping these lines.

SOlZ@ooi98 Biiil7 t A

PDR ADOCK 05000528'DRQ~

N

Mr. George W. Knighton Palo Verde Nuclear Generating Station Units 1, 2 and 3

PVNGS FSAR Update Spent Resin Piping Layout Page Two ANPP-31494 If you have any further questions on this matter, please contact William Quinn of my staff.

Very truly yours, E. E.

Van Brunt, Jr.

APS Vice President Nuclear Production ANPP Project Director EEVB Jr./TFQ/dim cc:

E. A. Licitra A. C. Gehr R.

P.

Zimmerman

IH

~>>

ANPP-31494 O.

STATE OF ARIZONA

)

) ss.

COUNTY OF MARICOPA)

I, A. Carter Rogers, represent that I am Manager, Nuclear Engineering of Arizona Public Service Company, that the foregoing document has been signed by me on behalf of Arizona Public Service Company with full authority to do so, that I have read such document and know its contents and that to the best of my knowledge and belief, the statements made therein are true.

A. Carter Rogers Sworn to before me this day 1984.

)

'y Commission Expires April 6, 398l My Commi:ssion Expires:

tary Public

1 (1"

C 0

E e

/

i, ~,4