IJ'<< '

REGULATOR INFORMATION DISTRIBUTION TEM (RIDS)

ACCESSION NBR;8407100240 DOC ~ DATE: 84/07/03 NOTARIZED:.YES DOCKET FACIL:STN-50 528 Palo Verde Nuclear Stationi Unit ii Arizona Publi 05000528 STN-50-529 Palo Verde Nuclear Stationi Unit 2i Arizona Publi 05000529 STN-50-530 Palo Verde Nuclear Station~

Unit 3i Arizona Publi 05000530 AUTH,NAME AUTHOR AFFILIATION VAN BRUNTiE F 6'rizona Public Service Co, RECIP ~ NAME RECIPIENT AFFILIATION KNIGHTONp G ~

Licensing Branch '3 SUBJECT; Forwards response to NRC 840420 request for addi info re initial test program.Revised sections of FSAR Chapter 14 included in response. Proposed revs will be incorporated in upcoming FSAR amend.

DISTRIBUTION CODE:

B001S COPIES RECEIVED:LTR ENCL SIZE

'TITLE: Licensing Submittal:

PSAR/FSAR Amdts L Related Correspondence NOTES:Standardized plant.

Standardized plant.

Standardized plant.

05000528 05000529 05000530 RECIPIENT ID CODE/NAME NRR/DL/ADL NRR LB3 LA INTERNAL; ELD/HDS3 IE/DEPER/EPB 36

, IE/DQASIP/UAB21 NRR/DE/CEB 11 NRR/DE/EQB 13 NRR/DE/MEB 18 NRR/DE/SAB 24 NRR/DHFS/HFEB40 NRR/DHFS/PSRB NRR/DS I/AEB 26 NRR/DS I/CPB 10 NRR/DSI/ICSB 16 NRR/DS I/PSB 19 NRR/DSI/RSB 23 RGN5 EXTERNAl,:

ACRS 41 DMB/DSS (AMDTS)

LPDR 03.

NSIC 05 COPIES LTTR ENCL 1

0 1

0 0

3 3

1 1

1.

1 2

2 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 3

3 6

6 1

1 1

1 1

RECIPIENT ID CODE/NAME NRR,LB3 BC LICITRAgE 01 IE FILE IE/DEPER/IRB 35 NRR/DE/AEAB NRR/DE/EHEB NRR/DE/GB 28 NRR/DE/MTEB 17 NRR/DE/SGEB 25 NRR/DHFS/LQB 32, NRR/DL/SSPB NRR/DS I/ASB NRR/DS I/CSB 09 NRR/DSI/METB 12 AB 22 04 RM/DDAMI/MIB BNL(AMDTS ONLY}

FEMA REP DIV 39 NRC PDR 02 NTIS COPIES LTTR ENCL 1

0 1

1 1

~ 1 1

1

=

0 1

1 2

2 1

1 1

1 1

1 1

0 1-1 1

1 1

1 1

1 1

1 0

1 1

1, 1

1 TOTAL NUMBER OF COPIES REQUIRED:

LTTR 53 ENCL 46

p pl jl t

Arizona Public Service Company P.o. BOX 21666

~

PHOENIX, ARIZONA 65036 ANPP-29875-EEVBJr/WFQ/KEJ July 3, 1984 Director of Nuclear Reactor Regulation Attention:

Mr. George Knighton, Chief Licensing Branch No.

3 Division of Licensing U.

S. Nuclear Regulatory Commission Washington, D.

C.

20555

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Units 1, 2, and 3

Docket Nos.

STN 50-528/529/530 File:

84-056-026; G.1.01.10

Reference:

Letter from G.

W. Knighton, NRC, to E. E. Van Brunt, Jr.,

APS, dated April 20, 1984.

Subject:

Request for Additional Information Initial Test Program for Palo Verde.

Dear Mr. Knighton:

Please find attached responses to the above referenced request for additional information concerning the Initial Test Program for Palo Verde.

Included in the responses to these questions, are revised sections of FSAR Chapter 14.

These proposed revisions will be included in an upcoming amendment to the FSAR.

If you have any further questions concerning this matter, please contact me.

Very truly yours, APS Vice President Nuclear Production ANPP Project Director EEVBJr/KEJ/mb Attachment 8407100240 840703 PDR ADOCK 05000M8 A

PDR

STATE OF ARIZONA

)

) ss.

COUNTY OF MARICOPA)

I, Donald

Karner, represent that I am Assistant Vice President, Nuclear Production of Arizona Public Service
Company, that the foregoing document has been signed by me on behalf of Arizona Public Service Company with full authority to do so, that I have read such document'nd know its
contents, and that to the best of my knowledge and belief, the statements made therein are true.

Donald Karner Sworn to before me this day o

, 198$.

) ~pl

)

I My Commission'-Expires:

MyCsem)sslcn F"pirss April 6, 'i867 Notary Public

00 I 'i 4

I A

~

Mr. George Knigh Initial Test Program Page 2

cc:

E.

D.

A.

W.

W.

T.

J.

M.

M.

T.

K.

S.

J.

J.

D.

0.

J.

R.

A.

E.

W.

S.

t, Jr.

E.

Van Brun B. Karner C. Rogers E. Ide F. Quinn F.

Quan Y. Morita A. Jones J. Winsor G.

Woods W. Gross R. Frost E. Kirby R.

Bynum R. Canady J. Zeringue D. Houchen A. Ferguson C. Gehr A. Licitra H. Wilson Shepherd (4060)

(w/a)

(4060)

(w/a)

(4056)

(w/a)

(4074)

(w/a)

(4057)

(w/a)

(4057)

(w/a)

(4057)

(w/a)

(4057)

(w/a)

(6254)

(w/a)

(1910)

(w/a)

(6088)

( /a)

(4080)

(w/a)

(6249)

(w/a)

(6125)

(w/a)

(1390)

(w/a)

(6130)

(w/a)

(6130)

(w/a)

(6225)

(w/a)

(4141)

(w/a)

(NRC)

(w/a)

(Bldg 43)

(w/a)

(Bldg 43)

(w/a)

V

~

NRC Question:

640.15 In response to Item 640.2 (Question 14A.3),

you stated that response will be provided on the CESSAR docket.

Provide a specific reference for that response.'PS

Response

Combustion Engineering submitted the Comprehensive Vibration Assess-ment Program (CVAP) report from the prototype System.,

80 plant (ie.

Palo Verde) for NRC review in a letter from A. E. Scherer, CE, to Darrell G. Eisenhut, NRC, dated February 16, 1984 (LD-84-008).

A copy of the cover letter is attached.

V I