REGULATO INFORMATION Dl'STRIBUTION STEM (RIDS)

ACCESSION NBR 8303040452 DOC ~ DATE: 83/02/25 NOTARXZEO:

NO DOCKET ¹ FACIL:STN,50 528 Palo Verde Nuclear StationE Uni.t li Arizona Publi 05000528 STN"50-529 Palo Verde Nuclear Stations Unit 2P Arizona Publi 05000529 STN 50-530 Palo Verde Nuclear StationE Unit 3E Arizona Publi 05000530 AUTH BYNAME AUTHOR AFFILIATION VAN BRUNTEF ~ ED Arizona <<Public Service

<<Co ~

<<RE<<CIP ~ NAME RECIPIENT AFFILIATION KNI'GHTONi'G ~

L')censing Branch <<3-

SUBJECT:

'Summar izes 821020 meeti,n'g w/NRC in BethesdagMD re <<removal of pipe whip restraints. Listed-info will be <<ptovided >to NRC by 830331" ~

DISTRIBUTI N

CODE:

800<<'8

'COPIES RECEIVED:L'TR J ENCL 'SIZE:.

<<TITLE: Licensing 'Submittal:

PSAR/FSAR Amdts K Related Correspondence NOTES:Standardized

<<plant ~

'Standardized

<<plant ~

Standardized

<<plant ~

05000528 05000529 05000530 RECIPIENT ID CODE/NAME,,

NRR/DL/ADL NRA LB3 LA

<<COPIES LTTR ENCL 0

]

~0 REC IP IENT "ID CODE/NAME NRR LB3 'BC LICITRAE E ~

Qi COPIES LT<<TR ENCL 1

0 1

INTERNALS ELD/HDS3 IE/DEP EPDS "35 NRR/DE/AEAB NRR/DE/EQB 13 NRR/DE/HGEB 30 NRR/DE/MTEB 17 NRR/DE/SAB 24 NRR/DHFS/HFEB40

,NRR/DL/SSPB NRR/DS I/ASB NRR/DSI/CSB 09=

NRA/DS I/METB 12'RAB'22 REG F Il 04

'D.Ai MIB EXTiERNAL: ACRS 41 DMB/DSS (AMDTS)

LPDR 03.

NSIC 05 1

1 12'

,1-1 1

1 1

1 1

1 6

1 1

~ 1 rQ 1

eQ

'2 1

1 1

1

~ Q 1

1

,1 1

1 eQ 6

1 1

1 IE'ILE IE/DEP/EPLB 36 NRR/DE/CEB 11 NRR/DE/GB 28 NRR/DE/MEB 18 NRR/DE/QAB 21 NRR/DE/SEB 25 NRR/DHFS/LQB 32 NRR/DSI/AEB 26 NRR/DSI/CPB 10 NRR/DSI/XCSB 16 NRR/DS I/PSB 19 NRR/DSI/RSB 23 RGN5 BNL(AMDTS.ONLY)

FEMA~REP DIV 39 NRC <<PDR 02 NTIS 1

1

<<3 "3

1 1

2 2

1 1

1 1

1 1

1 1

1 1

1 1

1 1-

<<3

<<'3

)TOTAL NUMBER OF 'COPIES REQUIRED:

L<<TTR 52 ENCL 45

i 10 i lfII ll lC

'Ii f i r f 'q ii g ( li r i.

l, ~ I)'

1 Ir II i

,"3,Tr..

eeee ee<<eee eeee ee ee

)fi>>ili li ) v3 frill IIfl Ifjr g3 Ifi Ifiif

,W fi, q f~ ".$

)>Y jl h[ ii i

l L

lL

Arizona Public Service Company P.o. BOX 21666

~

PHOENIX. ARIZONA 65036 February 25, 1983 ANPP-23100 WFQ/TFg Director of Nuclear Reactor Regulation Attention:

Mr. George Knighton, Chief Licensing Branch No.

3 Division of Licensing U.

S. Nuclear Regulatory Commission Wa'shington, D.

C.

20555 Subj ect:

Palo Verde Nuclear Generating Station (PVNGS) Units 1, 2 and 3

Docket Nos.

STN-50-528/529/530 File:

83-056-026 G.1.01.10

Reference:

Summary of October 20, 1982 meeting on Pipe Whip Restraints, E. A. Licitra, Project Manager, Division of Licensing, NRC, dated November 18, 1982.

Dear Mr. Knighton:

A meeting was held on October 20, 1982 in Bethesda, Maryland to discuss the removal of pipe whip restraints.

During that meeting, the staff encouraged us to provide additional information with respect to potential reduction in occupational radiation exposure and costs if the restraints in the RCS Loops were eliminated and information which clearly indicates that leaks can be detected before they could result in a pipe break.

We intend to supply the information sought by the NRC staff.

During the discussion, results of fracture mechanics analyses performed with nominal material properties were presented in substantiation of "leak before break".

The staff expressed concern about the use of nominal material data in the analysis.

We agreed to examine the possibility of repeating the analysis using signifi-cantly degraded material properties in order to demonstrate that the conclu-sions are valid for materials having properties significantly lower than the validity of leak before break.

We will provide the following information to the staff by March 31, 1983.

2.

3 ~

4.

An estimate of the potential reduction in cost and occupational radiation exposure if the restraints are eliminated.

A tabulation of the break locations for which pipe whip restraints'are currently employed and whose elimination is desired, including a detail of the geometry and materials.

A detailed description of the support system including material fabrication, installation and design margin.

A summary of fracture mechanics analyses in support of leak before break, including analyses using significantly degraded material properties.

,8303040452'830225 Ii;;PDR.ADOCK 05000528

I

G. Knighton February 25, 1983 ANPP-23100 WFQ/TFQ Page 2

We believe that this information, together with the results of the probabilistic analysis being performed by Lawrence Livermore Laboratories will provide a sufficient technical and benefit basis to assist the staff in evaluating the elimination of pipe whip restraints.

Very truly yours, E.

E. Van Brunt, Jr.

APS Vice President, Nuclear Projects ANPP Project Director EEVBJr/TFQ/sp cc:

E. A. Licitra K. Berlin A. C.

'Gehr

I