Forwards Pump & Valve Inservice Testing Program Palo Verde Unit 1, in Response to SER Open Item 6.Program Includes Any Relief Requests from ASME Section XI
ML17297B446
Person / Time
Site: Palo Verde  Arizona Public Service icon.png
Issue date: 04/12/1982
From: Van Brunt E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To: Tedesco R
Office of Nuclear Reactor Regulation
Shared Package
ML17297B447 List:
References
RTR-NUREG-0857, RTR-NUREG-857 ANPP-20680-WFQ, NUDOCS 8204190330
Download: ML17297B446 (6)


Text

REGULATO INFORMATION DISTRIBUTION TEM

('R IDS)

ACCESSION NBR:820 FACIL:STN>>50~528 STN 50-529 STN 50 530 AUTH,NAME VAN BRUNTgE ~ ED

'REC IP ~ NAME TEOESCOiR ~ LE 4190330 DOC ~ DATE: 82/04/12 NOTARIZED:

YES Palo Verde Nuclear Station~

Unit fr Arizona Publi Pa]o Verde Nuclear Stat)one Uni!t 2i Arizona Publ i Palo Ver de Nuclear Station~

Unit 3< Arizona Publi AUTHOR AFFILIATION Arizona '-Public Service Co.

RECIPIENT AFFILIATION, Assistant Director for Licensing DOCKET 05000528 05000529 05000530

SUBJECT:

For wards "Pump L, Valve, Inservice Teston'g Program Paly Verde'nit ip" in response to 'SEP Open Itep 6 'rogram includes any relief requests from ASME Section XI.

DISTRIBUTION CODE:

B001S COPIES RECEIVED:LTR

ENCL

'SIZEt TITLE: PSAR/FSAR AMDTS and Related Correspondence NOTES:Standardized plant ~

Standardized planto S tandaydi zed p 1 an t ~

5AM 5'z /aMr4~

05000528 05000529 05000530 RECIPIENT ID CODE/NAPE A/O L ICENSNG LI C BR 0'3 LA INTERNAL: ELD IE/DEP/EPOB 35 MPA NRR/DE/EQB 13 NRR/DE/HGEB 30 NRR/DE/MTEB 17 NRR/OE/SAB 24 NRR/DHFS/HFEB40 NRR/DHFS/OLB 34 NRR/OS I/AEB 26 NRR/OS I/CPB 10 iVRR/DSI/ETSB 12 NRR/DSI/PSB 19 23 REG FI 04 EXTERNAL: ACRS 41 FEMA-REP OIV 39 NRC PDR 02 NTIS

'COPIES LTTR ENCL 1

0 1

0 1

0 1

1

.1 0

3 3

2 2

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 f0 fr0 1

1 1

1 1

1 RECIPE'ENT IO CODE/NAMF LIC BR N3 BC LICITRAiE ~

Of IE 06 IE/OEP/EPLB 36 NRR/DE/CEB 11 NRR/OE/GB 28 NRR/DE/MEB 18 NRR/OE/QAB 21 NRR/OE/SEB 25 NRR/OHFS/LQB 32 NRR/DHFS/PTRB20 NRR/OSI/ASB 27 NRR/DSI/CSB 09 NRR/OS I'/ICSB 16 NRR/DSI/RAB 22 NRR/OST/LGB 33 RGN5 BNL(AMDTS ONLY)

LPOR 03 NSIC 05

- COPIES LTTR ENCL 1

0 1

1 1

1 3

3 1

1 2

2 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

'2 2

1 1

1 1

1 TOTAL NUMBER OF COPIES REQUIRED:

LTTR 57 ENCL 52

p

'l l1 1t 1

)(

l3 R

IJ

'k sC V

O p

STA.

ÃWKlltV IKIIBHCBICQ&%HW P.O. BOX 21666 PHOENIX, ARIZONA65036 April 12, 1982 ANPP-20680 WFQ/KEJ Mr. R. L. Tedesco Assistant Director for Licensing Division of Licensing Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission; Washington, D.C.

20555 RKCSNKO" AI R 1 9 1982>>

llC

Subject:

Palo Verde Nuclear Generating Station (PVNGS) Units 1, 2 and 3

Docket Nos.

STN-50-528/529/530 File:

82-056-026'.1.10

Reference:

NUREG-0857, "Safety Evaluation Report" related to the Operation of Palo Verde Nuclear Generating Station (PVNGS) Units 1, 2 and 3, dated November,~.1981

Dear Mr. Tedesco:

Please find attached the PVNGS ASME Section XI Pump and Valve Testing Program for the preservice and inservice testing of pump and valves in response to Open Item No.

6 of the referenced SER, Section 3.9.6.

This program also includes any Relief Requests from ASME Section XI.

'lso included are P&IDIs referenced in the program for your use.

If you have any questions concerning this matter, please contact me.

Very truly ou CU'J E. E. Van Brunt, Jr.

APS Vice President, Nuclear Projects ANPP Project Director EEVBJr/KEJ/de Attachment (w/a) cc:

E. Licitra P. L. Hourihan (w/a)

R. L. Greenfield (w/a)

A. C. Gehr D. Terao

- noh S204190330 S20412 PDR *DOCK 0500052S E

PDR I

j 44 C

C,BUSDQR

~" ~$886I >>qp,

~s J ~ 1L&fj0 Q~g g iN iY>ViNCRjg,"j) 0; Wf M~w sw i(

k

~

~i i

i

f yli

~

STATE OF ARIZONA

)

) ss.

COUNTY OF MARICOPA)

I; Edwin E. Van Brunt, Jr., represent: that I am Vice President Nuclear Projects of Arizona Public Service Company, that the foregoing document has been signed by me on behalf of Arizona Public Service Company with full authority so to do, that.I have read such document and know its contents, and that to the best of my knowledge and belief, the statements made therein are true.

/

Edwin E.,Van Brunt, Jr.

Q Lgi(

r

~

yP.

Sworn to before me thfa~Zday of 1981.

Notary Public My Commission expires:

MyCommission Expires Dec. 22, '1985 r ~

~ ~

e

~

I I ~

~t:,e C'y 0,

~

0

)

O C g<,C

'I 'P

~

C 1

h