ML17297B138

From kanterella
Jump to navigation Jump to search
Clarifies Intended Functional Assignments Discussed During ACRS 811123 & 24 Subcommittee Meeting.Overall Mgt & Direction of Onsite Emergency Response Will Continue to Be Performed Under Direction of Technical Support Ctr Director
ML17297B138
Person / Time
Site: Palo Verde  Arizona Public Service icon.png
Issue date: 12/07/1981
From: Van Brunt E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To: Tedesco R
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0696, RTR-NUREG-696 ANPP-19613-JMA, NUDOCS 8112310397
Download: ML17297B138 (8)


Text

"REGULA VRY "INFORMAtTION DISTRIBUTIO

'SYSTEM

('RIDS)

AOCBSSION NBR:8112310397

.DOC ~ DATE: '81/12/07 NOTARIZED:, YES FACIL STN 50 528 lPal o Verde Nucl ear Stat ianna Uniit 1 j Ar i zona Publ i

'STN 50.529 iPalo Vendo Nuclear Stations Uniit '2r Arizana Publi

'STN.50 '530 )Palo Vende Nuclear Stations Uni~t >3r Ar izona Publ i

'AUTH BYNAME AUTHOR AFFILIATION VAN BRUNTEE.E, Arizana IPublic Senvice Co ~

lRE}CI'P ~ NAME.

RECIPIENT AFFILIATION, TiEOESCOER ~ LE Assistant Director for Licensing DOCKET 05000528 05000529 05000530

SUBJECT:

Clarifies intended functional assi'gnmeqbs discussed during ACRS 811123

=K 2Q <<subcommittee meeting

~ Overall mgt

'8 direction of onsilte <<emengency response will continue to be performed under directian af technical <<support ctr director.

DISTRIBUTION.CODE:

B001S

>COPIES iRECEIVED:LTR.J ENCL.

SIZE:,

TITLE: PSAR/FSAR

'AMDTS and Related ICorrespondence NOTES Standardized IPlant F 1 cy!C Grimes Standardized

!Plant, 1 cy.'C Grimes

-'Standardized (Plant.

1 cy:C Grimes 05000528 05000529 05000530 RECIPIENT ID CODE/NAME ACTION:

A/D LICENSNG LIC BR 03 LA INTERNAL: FLD IE/DEP/EPDB

'.35 MPA NRR/OE/EQB 13 NRR/DE/HGEB

-30 NRR/DE/MTEB 17 NRR/DE/SAB 20 NRR/DHFS/HFEB40 NRR/DHFS/OLB 3Q NRR/DS I/AEB 26

,NRR/DSI/OPB 10 NRR/OS I/BTSB 12 NRR/DS I/PSB 19

.R/

RSB 23 REG F

04 EXTERNAL: AGRS 41 FEMA REP OIV "39 NRC PDR 02 NT I'

<<COPIES LTTR ENCL 1

1 e

1 1

]

o 2

1 1

1 1

1 1

1 1

1 1

1 1

1 1

RECIPIENT ID 'CODE/NA'ME LI'C BR 43 BC KERR I GANEFJ ~

01 IE 06 IE/DEP/EPLB 36 NRR/DE/CEB 11 NRR/DE/GB 28 NRR/DE/MEB 18 NRR/DE/QAB 21 NRR/DE/SEB 25 NRR/QHFS/LQB 32 NR R/D HF 8/iP0TiR B 2 0 NRR/DS I/ASH 27 NRR/DS I/CSB 09 NRR/DS I/IiCSB 16 NRR/DS I/RAB 22 NRR/DST/L'GB 33 B NL (AMDT'S.O NLY )

LPDR "03 NSIC 05 COPIES LTiTR ENCL I"3 "3

1 42 1

1 1

1 1

1 1

1 1

Cog 0

)TOTAL NUMBER OF COPIES REQUIRED>

UTTR

,. P3

,.ENCL

ll

\\

{

I

~ F, ~

Nl

STA.

P.o. BOX 21666 PHOENIX, ARIZONA85036 December 7,

1981 ANPP-19613 JMA/TFq Mr. R. L. Tedesco Assistant Director for Licensing Division of Licensing Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.

20555 phd Ã"-

OF Cg 0 )98)~

gggt5 55@@

~~'mc Cy

Subject:

Palo Verde Nuclear Generating Station

~ (PVNGS), Units 1, 2 and 3

Docket Nos.

STN-50-528/529/530 File:

81-056-'026; G.1.10

Reference:

PVNGS ACRS Subcommittee Meeting, Phoenix, Arizona, November 23 and 24, 1981

Dear Mr. Tedesco:

During the referenced

meeting, an apparent misunderstanding of the functional responsibilities of the Palo Verde TSC and Mini-TSC was identified.

We would like to take this opportunity to further describe our intended functional assignments for these two facilities.

A TSC is being constructed onsite to fulfillthe functional responsibilities described in NUREG-0696.

The TSC is centrally located to serve each of the three Palo Verde units.

The Xunctions which will be performed in 'the TSC are as follows:

1.

Manage onsite emergency response 2.

Direct radiologic'al protection activities 3.

Direct emergency mechanical maintenance 4.

Direct emergency electrical maintenance 5.

Direct personnel accountability and site security 6.

Direct safety and hazards control

rafffffffffff~

/'~~'189i 9 8 ">'0

"-@AM@em~~ v~.g y >.',

C~

cv 4't.t Il I

cy If if

Mr. R. L. Tedesco December 7, 1981 ANPP-19613 JMA/TFQ Page 2

7.

Perform engineering and technical analyses for control room support 8.

Perform reactor analyses for control room'support 9.

Provide emergency I & C technical support 10.

Provide computer technical support ll.

Provide chemistry technical support Since the central location of the TSC will"not provide face-to-face interaction with the control room within two minutes as specified in NUREG-0696, a Mini-TSC is being provided adjacent to the control room in each unit.

The Mini-TSC will function as an extension of the TSC to provide direct technical support to the control room personnel in the areas of:

l.

Engineering and technical analytical support 2.

Reactor analytical support 3.

Radiological analytical support While performing these functions in the Mini-TSC, the overall management and direction of onsite emergency response will continue to be performed under the direction of the TSC director.

If you have any questions or comments on our intended functional uses of the TSC and Mini-TSC, please feel free to contact us.

Very truly yours, E.

E. Van Bru

, Jr.

APS Vice Pres

ent, Nuclear Projects ANPP Project Director EEVBJr/TFQ/av cc:

J. Kerrigan P. Hourihan A. C. Gehr

l't ll f,

II

STATE OF ARIZONA

)

)

sate COUNTY OF MARICOPA)

I, John M. Allen, represent that I am Nuclear Engineering Manager of Arizona Public Service Company, that the foregoing document has been signed by me for Edwin E. Van Brunt, Jr., Vice President Nuclear Projects, on behalf of Arizona Public Service Company with full authority so to do, that I have read such document and know its contents, and that to the best of my knowledge and belief, the statements made therein are true.

hn M. Allen Sworn ro before me shish-L dey of W~C.~M/3

, 1981.

otary Public My Commission expires:

t 4

/

C

~