ML17297A739

From kanterella
Jump to navigation Jump to search
Submits Mods to 810501 Responses to NRC Short & long-term Generic Recommendations Re Auxiliary Feedwater Sys.Auxiliary Feedwater Sys Tech Spec Will Be Modified to Incorporate Third Auxiliary Feedwater Train
ML17297A739
Person / Time
Site: Palo Verde  
Issue date: 08/26/1981
From: Van Brunt E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To: Tedesco R
Office of Nuclear Reactor Regulation
References
ANPP-18770-JMA, NUDOCS 8109010123
Download: ML17297A739 (8)


Text

REGUL ORY INFORMATION DISTRIBUT SYSTEM (RIDS)

ACCESSION NBR: 810 FACILi:STN 50~528 STN 50 529 STN~50 530 AUTH'AMEl VAN BRUNTPEi,ED REC IP ~ NAMKI TEDESCOPR

~ Li, 9010123 DOC ~ DATEi0 81/08/26 NOTARIZED:

NO Palo Verde Nuclear StationP Unit li Arizona Publi Palo Verde Nuclear Stationi Unit 2~ Arizona Publi Palo Verde Nuclear Station<

Unit 3i Arizona Publi AUTHOR AFFILIATIO~

Arizona Public'ervice.

Co ~

RECIPIENT AFFILIATION Assistant Director for Licensing DOCK

¹ 05 05000529 05000530

SUBJECT:

. Submits mods to 810501 responses to NRC short 8

long. term generic recommendations re auxiliary feedwater sys.Auxiliary feedwater sys Tech will be modified to incorporate. third auxiliary feedwater train.

DISTRIBUTION CODES BDOIS COPIES RECEIVED:LTR )

ENCL: Q SIZE:

~

TITLKI: PSAR/FSAR AMDTS and Related Correspondence NOTES:Standardized

Plant, 1

cy.'C Grimes Standardized P'lant F 1 cy'.C Grimes Standardized Plant F 1 cy!C Grimes 05000528 05000529 05000530 RECIPIENT ID'ODE/NAMKf ACTION:

A/D LICENSNG LIC BR ¹3 LA INTERNAL: ACCID KVAL BR26 CHEM ENG BR il CORE PERP BR 10.,

EMRG PRP DEV 35 EQUIP QUAL BR13i GEOSCIENCE 8 28 HYD/GEO. BR 30 '

LKl 06 LI C QU AL BR 32",

MECH ENG BR 18 OELD PO'AER SYS BR 19 QA BR 21 REAC SYS BR 23i SIT'NAL BR 24 COPIES LTTR ENCL 1

1 1

1 2

2 3

1 1

1 1

1 1

RECIPIENT ID CODE/NAME LiIC BR ¹3 BC KERRIGANgJ ~

04 AUX SYS BR 27 CONT SYS BR 09 EFF TR SYS BR12 EMRG PRP LIC 36 FEMA REP DIV 39 HUM FACT ENG 40 ILC SYS BR 16 LiIC GUID BR 33 MATLi ENG BR 17

%PA OP LIC BR 34 PROC/TST REV 20 R

ESS BR22 EG F

01 NG BR25 COPIES LTTR ENCL 1

1 1

1 1

3 1

1 1

1 1

1 0

1 1

1 1

1 1

1 1

EXTERNALi:- ACRS 41 NRC PDR 02 NTIS 16 1

1 LPDR NSIC 03 05-TOTAL NURBERi OF COPIES REQUIRED:

LTTR 2

ENCL

4 I'

a

=1 w

I

,J

g p

MUIMIMl IZBEWVKIOSIIS OXSEBIKaMW STA.

P.o. BOX 21666 PHofNIX,ARIZONA85036 Aug'ust 26, 1981 ANPP-18770 JMA/TFQ Mr. R. L. Tedesco Assistant Director for Licensing Division of Licensing Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.

20555 yPi I iz yX (g gygk,~

'ubject:

Palo Verde Nuclear Generating Station

'(PVNGS) Units 1, 2 and 3

Docket Nos.

STN-50-528/529/530 File:

81-056-026 G.1.10

References:

(A)

Letter from D. F. Ross, NRC, to All Pending OL Applicants of NSSS Designed by Westinghouse and Combustion Engineering, dated March 10, 1981 (B)

Letter from E.

E. Van Brunt, Jr.,

APS, to H. R.

Denton dated May 1, 1981, ANPP-17884 JMA/TFQ (C)

Letter from R. L. Tedesco, NRC, to E.

E. Van Brunt, Jr.

dated June 22, 1981, subject:

PVNGS Units 1, 2 and 3 Safety Evaluation Report Input for the Auxiliary Feed-water System

Dear Mr. Tedesco:

Reference (A), Enclosure 1, stated a number of short term generic, additional short term, and long term generic recommendations.

These recommendations were addressed in Reference (B).

Subsequently, several of our responses were modified.

These modifications were conveyed to the NRC staff reviewer, by telephone, and are noted as sub-sequent conversations in Reference (C).

The modifications are hereby sub-mitted for your information goo j 5

~h 8i09010i23 8i082Z PDR AoaCX OSOOOSas

~ A PDR

/

h w

P C,

'LN KJ'f P

Mr. R. L. Tedesco August 26, 1981 ANPP-1877O JMA/TFq Page 2

Recommendation GS-6 AFW System Flow Path Verification

~Res onse When an AFW system flow train has been out of service to perform testing or maintenance, the flow path availability will be confirmed by:

1.

Implementing procedures that require an operator to determine that the AFW system valves are properly aligned and a second operator to independently verify and sign off on the procedure that the valves are properly aligned.

2.

PVNGS will adopt Technical Specifications to assure that prior to plant startup following a refueling shutdown or any cold shut-down 30 days or longer, a flow test will be performed to verify the normal flow path from the primary AFW system water source to the steam generators.

Recommendation 5.3.2 AFW Pump Endurance Test

~Res ones PVNGS will perform as part of the startup test requirements a 48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> endurance test on the AFW system pumps.

Following the 48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> pump run, the pumps will be shutdown and cooled down and then restarted and run for one hour.

Test acceptance criteria will include demonstrating that the pumps remain within design limits with respect to bearing/bearing oil temperatures and vibration and for the two (2) essential AFW system pumps that the pump room ambient conditions do not exceed environmental qualification limits for safety-related equipment in the room.

Recommendation 5.3.4 AFW System Availability During Periodic Surveillance Testing

~Res onse PVNGS will require local manual re-alignment of valves to conduct periodic test on one AFW system train and will have one remaining essential AFW train available for operation.

In addition, the startup'FW pump, which is provided with an emergency power source, will be available to supply auxiliary feed-water to the steam generators from the condensate storage tank.

The flow path used by the startup AFW pump is separate from the essential AFW pump flow paths.

Mr. R. L. Tedesco August 26, 1981 ANPP-1877O JMA/TFq Page 3

The reactor operator will be informed of the periodic test being per-formed on the AFW system train prior to the test, through a status list for equipment which is required to be tested by the standard Technical Specifications.

Through normal training and caution statements in the periodic testing procedure, the reactor operator will be aware that manual action is required should an AFAS be actuated during a periodic test of an AFW train.

The Auxiliary Feedwater System Technical Specification will be modified to incorporate the third AFW train.

Please contact me if you have any other questions on these matters.

I Very truly yours (JET W~L.

E. E. Van Brun't, Jr.

APS Vice President, Nuclear Projects ANPP Project Director EEVBJr/TFQ/av cc: