- P~c WQC3M(Q lX (QCSEQEBRH'P P. O. BOX 2I666 PHOENIX'RIZONA 85036 March 11, 1980 ANPP-15007 - JMA/WFQ 4::/
Docket Nos.
50-528,
- 529, 530 Mr.
R.
H. Engelken, Director U.S. Nuclear Regulatory Commission Region V
202 Walnut Creek Plaza 1990 N. California Boulevard Walnut Creek, California 94591
Subject:
NRC I8E Bulletin No; 79-28 Possible Malfunction of Namco Model EA180 Limit Switches at Elevated Temperature File:
D.4.01;1;'80-005-'026
Reference:
(A)
ANPP-14788 - JMA/WFQ dated February 8, 1980
Dear Mr. Engelken:
This letter serves to supplement our original response, Reference (A), to NRC I8E Bulletin No. 79-28.
We have determined. that the subject limit switch is also supplied on a l-l/2 inch pneumatic operated gate valve, CH-580, through a
CE purchase order with Borg Warner.
Please be advised that Borg Warner has been notified of the concern and has replaced the gaskets on the limit switches, prior to shipment of Valve CH580, as required by the subject Bulletin.
Very truly yours, E.Cv~~
E.
E.
Van Brunt, Jr.
APS Vice President, Nuclear Projects ANPP Project Director EEVBJr/WFQ/av cc:
J.
M. Allen J.
A. Roedel F.
W; Hartley W. H. Wilson C. Ferguson NRC Office of Inspection
& Enforcement Division of Reactor Inspection Programs Washington, D.C. 20555 80072 0
)~