Text

0'

..pi IFWMIHQ ~lal CIDZUIWEWw U.

S. Nuclear Regulatory Commission Region V

Walnut Creek Plaza Suite 202 1990 North California Boulevard Walnut Creek, California 94596 P. O. BOX ZI666 PHOENIX, ARIZONA 85036 March 6, 1980 ANPP-14973-JAR I

I

~l Attention:

Mr. G.

S. Spencer, Chief Reactor Construction and Engineering Support Branch

Subject:

A 50.55(e)

Reportable Condition Relating to Safety-Related Pipe Support Assemblies File:

80-019-026

Reference:

Telephone Conversation between L. Vorderbrueggen and J. A. Roedel, January 31, 1980

Dear Sir:

Attached, is our final written report of the reportable deficiency under 10CFR50.55(e) relating to safety-related 'pipe support assemblies installed in Unit //1 of the Palo Verde Nuclear Generating Station.

Very truly your EEVBJr/JAR:skc Attachment E.

E. Van Brunt, Jr.

APS Vice President Nuclear Projects ANPP Project Director cc:

Victor Stello, Jr., Director Office of Inspection and Enforcement U.

S. Nuclear Regulatory Commission Washington, D.

C.

20555 A. C.

Gehr Snell

& Wilmer

-R. L.

L.

W.

W. E.

B.

S.

W. H.

W. G.

J.

E.

W. J.

Robb Price Ide Kaplan Wilson Bingham Bashore Stubblefield 8 00 OPOP.55 zp

0 il