PRIORIT'Y Z
NUDOCS OFFSITE FACILITY)
REGULATO
INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:9511210016
DOC.DATE: 95/ll/14
NOTARIZED:
NO
ACIL;50-397 WPPSS Nuclear Project, Unit 2, Washington Public
Powe
AUTH.NAME
AUTHOR AFFILIATION
WYNN,T.P.
Region
4 (Post
820201)
RECIP.NAME
RECIPIENT AFFILIATION
PARRISH,J.V.
Washington Public Power Supply System
SUBJECT:
Forwards
insp rept 50-397/95-30
on 950925-28
& notice of
violation.
DOCKET ¹
05000397
P
R
i
DISTRIBUTION CODE:
IEOSD
COPIES
RECEIVED:LTR J
ENCI J
SIZE:
+2 +
TITLE: Environ
a Radiological
(50 DKT)-Insp Rept/Notice of Violation Respons
NOTES:
0,
RECIPIENT
ID CODE/NAME
PD4-2
INTERNAL: ACRS
PI L'E "C JN TER>>
RR/DISP/PIPB
OE DIR
RGN4
FILE
01
EXTERNAL: NOAC
COPIES
LTTR ENCL
1
1
2
2
1
1
1
1
1
1
1
1
1
1
RECIPIENT
ID CODE/NAME
CLIFFORD,J
AEOD/TTC
'NMSS/SFPO
06F18
NUDOCS-ABSTRACT
OGC/HDS3
NRC
COPIES
LTTR ENCL
1
1
1
1
1
1
1
1
1
1
1
1
R'
D
U
NOTE TO ALL"RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE ivASTE! CONTACTTHE DOCUMENTCONTROL
DESK, ROOM Pl-37 (EXT. SQ4-20S3 ) TO ELIMINATEYOUR NAh!E FROM
DIS I'RIBUTIONLIS'M I'OR DOCUMENTS YOU DON"I'NEED!
TOTAL NUMBER OF COPIES
REQUIRED:
LTTR
14
ENCL
14
~jj,S REQQC
~C
~o
+
-~ ~a
oQ
IP ++*>>>>
UNITED STATES
NUCLEAR REGULATORY COMMISSION
REGION IV
611 RYAN PLAZADRIVE, SUITE 400
Nov ] g g
Washington Public Power Supply System
ATTN:
J.
V. Parrish.
Vice President
Nuclear Operations
3000 George Washington
Way
P.O.
Box 968.
HD 1023
Richland.
99352
SUBJECT:
NRC
INSPECTION REPORT 50-397/95-30
This reters to the inspection
conducted
by Messrs.
L. T. Ricketson
and
H.
P.
Shannon of this office on September
25-28.
1995, at the Washington
Nuclear Project-2 facility.
The purpose of the inspection
was to determine
whether activities authorized
by the license were conducted safely and in
accordance
with NRC requirements.
At the conclusion of the inspection,
the
findings were discussed
with you and those
members of your staff identified in
the enclosed
report.
Areas examined during the inspection are identified in the report.
Within
these
areas,
the inspection consisted of selective examinations of procedures
and representative
records,
interviews with personnel.
and observation of
activities in progress.
Based
on the results of this inspection,
the
NRC has determined that
a
violation of NRC requirements
occurred.
The violation is cited in the
enclosed
Notice of Violation (Notice) and the circumstances
surrounding it are
described
in detail in the'subject
inspection report.
The violation is of
concern
because it involved the failure to maintain
a locked door for entry
into an area in which the radiation levels exceeded
1000 mRems/hr.
You are required to respond to this letter
and should follow the instructions
specified in the enclosed
Notice when preparing your response.
In your
response,
you should document the specific actions taken
and any additional
actions
you plan to prevent recurrence.
Your response
may reference or
include previous docketed
correspondence. if the correspondence
adequately
addresses
the required
response.
After reviewing your
response to this
Notice, including your proposed corrective actions
and the results of future
inspections,
the
NRC will determine whether further
NRC enforcement action is
necessary
to ensure
compliance with NRC regulatory requirements.
In addition to,responding to the Notice,
we also request that the Washington
Public
Power
Supply System address
the weaknesses
identified during the
inspection regarding the continued
problems in assuring that adequate
verifications are performed
This issue is discussed
in Section 2.7 of the
enclosed
inspection report.
'75ii2i00ih 95iii4
ADQCK 050003'77
8
Washington Public Power
Supply System
-2-
In accordance
with 10 CFR 2.790 of the NRC's "Rules of Practice,"
a copy of
this letters its enclosure(s).
and your response will be placed in the
NRC
Public Document
Room (PDR).
To the extent possible.
your response
should not
include any personal
privacy, proprietary.
or safeguards
information so that
it can
be placed in the
PDR without redaction.
The responses
directed
by this letter and the enclosed
Notice are not subject
to the clear ance procedures
of the Office of Management
and Budget
as requi red
by the Paperwork
Reduction Act of 1980.
Pub.
L. No. 96.511.
Should you have
any questions
concerning this inspection,
we will be pleased
to discuss
them with you.
Sincerely,
~~Thomas
P.
Gwynn, Director
Division of Reactor
Safety
Docket:
50-397
License:
Enclosures:
1.
Notice of'iolation
2.
NRC Inspection
Report
50-397/95-30 w/attachments
cc w/enclosures:
Washington Public Power Supply System
ATTN:
J.
H.
Swai les.
WNP-2 Plant Manager
P.O.
Box 968.
MD 927M
Richland,
99352-0968
Washington Public Power Supply System
ATTN:
Chief Counsel
3000 George Washington
Way
P.O.
Box 968,
HD 396
Richland,
99352-0968
Energy Facility Site Evaluation Council
ATTN:
Frederick
S. Adair, Chairman
P.O.
Box 43172
Olympian
98504-3172
Washington Public Power
Supply System
-3-
i
Washington Public Power
Supply System
ATTN:
D. A. Swank,
WNP-2 Licensing Hanager
P.O.
Box 968 (Hail Drop PE20)
Richland,
99352-0968
Washington Public Power Supply System
ATTN:
P.
R.
Bemis, Director
Regulatory
and Industry Affairs
P.O.
Box 968 (Hail Drop PE20)
Richland,
99352-0968
Benton County Board of Commissioners
ATTN:
Chairman
P.O.
Box 190
Prosser,
99350-0190
Winston 8 Strawn
ATTN:
H.
H.
Phi lips.
Esq.
1400
L Street,
N.W.
D.C.
20005-3502
Washington Public Power
Supply System
-4
E-Hail report to D. Nelson
(DJN)
E-Hail report to
NRR Event Tracking System
(IPAS)
<<< bccto
DMB ('IE06)
bcc distrib. by RIV:
L. J. Callan
DRS-PSB (Goines)
Branch Chief (DRP/E.
WCFO)
Senior Project Inspector
(DRP/E,
WCFO)
Leah Tremper
(OC/LFDCB,
HS:
TWFN 9E10)
WNP-2 Resident
Inspector
HIS System
RIV File
Br anch Chief (DRP/TSS)
M.
Hammond
(PAO.
WCFO)
DOCUHENT NAHE:
0:KFIPBtLTRtWN530RP.LTR
DRS AI 95-123
To receive copy of document, indicate In box: "C" ~ Copy
ihout enc
sures
"E" ~ Copy with enclosures "N" ~ No copy
RIV: PSB
E
C: PSB
E
D:DR
D:DRP
D:DRS
LTRicketson*
10/30/95
BHurray*
10/30/95
previous y concur re
TPGwynn
11/
/95
f-
L
JEDyer
11//t/-/95
TPGwynn
1/r
/95