7590-01 I.
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON PUBLIC POWER SUPPLY SYSTEM DOCKET NO. 50-397 OTICE OF CONSIDERATION OF ISSUANCE OF AMENDMENT TO FACILITY OPERATING LICENSE PROPOSED NO SIGNIFICANT HAZARDS CONSIDERATION DETERMINATION AND OPPORTUNITY FOR A HEARING The U.S. Nuclear Regulatory Commission (the Commission) is considering issuing an amendment to Facility Operating License No.
NFP-21 issued to Washington Pub'lic Power Supply System (the licensee) for operation of the its Nuclear Project No.
2 (WNP-2) plant, located in Benton County, Washington.
The proposed amendment would (1) revise TS 3/4.4.2 and 3/4.5. 1 to require main steam system and automatic depressurization system safety/relief valve (SRV) surveillance testing within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after steam pressure and flow are adequate to do the testing; and (2) revise TS Table 4.3.7.5-1 to require SRV position indicator surveillance testing within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after steam pressure and flow are adequate to do the testing.
The intent of the change is to clarify when the 12-hour time period begins.
The licensee is also making a change to the TS SRV basis to clarify that testing SRVs at low power means testing them when there is adequate steam. pressure an'd flow.
Before issuance ot the proposed license amendment, the Commission will have made findings required by the Atomic Energy Act of 1954, as amended
{the Act), and the Commission's regulations.
940SlaooS0 9a05iOV PDR ADOCK';05000397 P
PDQR
](
I I
- 2'-
The Commission has made a proposed determination that the amendment request involves no significant hazards consideration.
Under the Commission's regulations in 10 CFR 50.92, this means that operation of the facility in accordance with the proposed amendinent would not (1) involve a significant increase in the probability or consequences of an accident previously evaluated; or (2) create the possibility of a new or different kind of accident from any accident previously evaluated; or (3) involve a
significant reduction in a margin of safety.
As required by 10 CFR 50.91(a),
the licensee has provided its analysis of the issue of no significant hazards consideration, which is presented below:
The Supply System has evaluated the proposed changes against the above standards as required by 10 CFR 50.91(a) and concluded that the change does not:
(1)
Involve a significant increase in the probability or consequences of any accident previously evaluated.
The potential delay in confirming safety relief valve (SRV),
SRV position indication (acoustic monitor, valve stem position indicators, and tailpipe temperature instruments),
and ADS operability during plant startup should not result in any change to the expected satisfactory completion of the required surveillance tests.
Surveillance testing that is conducted during the plant shutdown
- sequence, and during shutdown, provides reasonable assurance that the SR'e'll function when required.
Under the proposed
- change, plant test conditions would not be different than in the past since testing was not begun until adequate pressure for the duration of the test was achieved.
Therefore, this change does not involve a significant increase in the probability or: consequences of any accident previously evaluated.
(2)
Create the possibility of a new or different kind of accident from any accident previously evaluated.
The proposed changes do not involve a design change nor do they involve changes outside the. scope ef the existing test requirements.
No new failure modes are introduced as a result of the proposed changes.
The acoustic monito'rs merely provide
44
indication that an SRV is open.
They do not provide an actuation signal.
Alternate mechanisms of SRV position indication exist, i.e, reactor water level changes, reactor pressure
- changes, main turbine bypass valve position, SRV tail pipe temperature, suppression pool level, and suppression pool temperature.
The time delay prior to operability verification will not affect
'echnical Specification requirements.
Therefore, the proposed changes do not create the possibility of a new or different kind of accident from any accident previously evaluated.
(3)
Involve a significant reduction in a margin of safety.
The proposed changes have no impact on the operability or performance requirements of the SRVs, including the ADS function, as they do not change the lift setpoints or minimum number of valves required to be operable.
The effect of delaying the starting point of the time clock is not expected to affect completion of the required tests.
ADS/SRV position indication availability will not be significantly affected by the proposed change since the additional 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> per refueling cycle of not verifying SRV, SRV position indication, and ADS SRV operability occurs at low power with the High Pressure Core Spray and Reactor Core Isolation Cooling systems available.
Additionally, there is a high probability that the SRVs would perform their intended function if required even though they have not been declared operable.
Therefore, the proposed changes do not involve a significant reduction in a margin of safety.
The NRC staff reviewed the licensee's analysis
- and, based on this review, it.,appears that the three standards of 10 CFR 50.92(c) are satisfied.
Therefore, the NRC staff proposes to determine that the amendment request involves no significant hazards consideration.
,. The Commission is seeking public comments.on this pr'oposed determination.
Any comments received within 30 das after the date of publication of this noti"e will be considered in making any final determination.
Normally, the Commission will not issue the amendment until the 30-day notice period expires.
- However, should circumstances change
l
(
l
)
fl 4
jl
during the notice period such that failure to act in a timely way would result, for example, in derating or shutdown of the facility, the Commission may issue the license amendment before the expiration of the 30-day notice period, provided that its final determination is that the amendment involves no significant hazards consideration.
The final determination will consider all public and State comments received.
Should the Commission take this action, it will publish a notice of issuance in the FEDERAL REGISTER and provide for opportunity for a hearing after issuance.
The Commission expects that the need to take this action will occur very infrequently.
Written comments may be 'submitted by mail to the Rules Review and Directives Branch, Division of Freedom of Information and Publications
- Services, Office of Administration, U.S. Nuclear Regulatory Commission, Washington, DC 20555, and should cite the publication date and page number of this FEDERAL REGISTER notice.
Written comments may also be delivered to Room 6D22, Two White Flint North, 11555 Rockville Pike, Rockville Maryland, from 7:30 a.m. to 4:I5 p.m.
Federal workdays.
Copies of written comments received may be examined at the NRC Public Document Room, the Gelman Building, 2120 L Street, NW., Washington, DC 20555.
The filing of requests for hearing and petitions for leave to intervene is discussed below.
By June ]3
]994
, the licensee may.,-file a r'equest for a hearing I ~
with respect to issuance of the amendment to the subject facility operating
- license, and any person whose interest may be affected by this proceeding and who wishes to participate as a party in the proceeding must file a
written request for a hearing and a petition for leave to'ntervene.
Requests for a hearing and a petition for leave to intervene shall be filed in accordance with the Commission's "Rules of Practice for Domestic Licensing Proceedings" in 10 CFR Part 2.
Interested persons should consult a current copy of 10 CFR 2.714 which is available at the Commission's Public Document Room, the Gelman Building, 2120 L Street, NW., Washington, DC 20555 and at the local public document room located at the'ichland Public Library, 955 Northgate Street,
- Richland, Washington 99352.
If a-
,request for a hearing or petition for leave to intervene is filed by the above date, the Commission or an Atomic Safety and Licensing Board, designated by the Commission or by the Chairman of the Atomic Safety and Licensing Board Panel, will rule on the request and/or petition; and the Secretary or the designated Atomic Safety and Licensing Board will issue a
notice of hearing or an appropriate order.
As required by 10 CFR 2.714, a petition for leave to intervene shall set forth with particularity the interest of the petitioner in the proceeding, and how that interest may be affected by the results of the proceeding.
The petition should specifically explain the reasons why intervention should be permitted with particular reference to the following factors:
(1) the nature of the petitioner's right under the Act to be made
't party to the proceeding; (2) the nature and extent of the petitioner's prope'.4y, financial, or other interest in the proceeding; and (3) the possible effect of any order which may be entered in the proceeding on the petitioner's interest.
The petition should also identify the specific aspect(s) o7 the subject matter of the proceeding as to which petitioner
wishes to intervene.
Any person who has filed a petition for leave to intervene or who has been admitted as a party may amend the petition without requesting leave of the Board up to 15 days prior to the first prehearing conference scheduled in the proceeding, but such an amended
'etition must satisfy the specificity requirements described above.
Not later than 15 days prior to the first prehearing conference scheduled in the proceeding, a petitioner shall file a supplement to the petition to intervene which must include a list of the contentions which are sought to be litigated in the matter.
Each contention must consist of a 'specific statement of the issue of law or fact to be raised or controverted.
In addition, the petitioner shall provide a brief explanation of the bases of the contention'nd a concise statement of the alleged facts or expert opinion which support the contention and on which the petitioner intends to rely in proving the contention at the hearing.
The petitioner must also provide references to those specific sources and documents of which the petitioner is aware and on which the petitioner intends to rely to establish those facts or expert opinion.
Petitioner must provide sufficient information to show that a genuine dispute exists 4
with the applicant on a material issue of law or fact.
Contentions shall be limited to matters wi'thin the scope of.the amendment under consideration.
The. contention must be one which, if proven, would entitle the petitioner to relief.
A petitioner who fails to file such a supplement which satisfies these requirements with respect to at least one contention will not be permitted to participate as a party.
Ii
'I
Those permitted to intervene become parties to the proceeding, subject to any limitations in the order grantiag leave to intervene, and have the opportunity to participate fully in the conduct of the hearing, including the opportunity to present evidence and cross-examine witnesses.
If a hearing is requested, the Commission will make a final determination on the issue of no significant hazards consideration.
The final determination will serve to decide when the hearing is held.
If the final determination is that the amendment request involves no significant hazards consideration, the Commission may issue the amendment and make it immediately effective, notwithstanding the request for a hearing.
Any hearing held would take place after issuance of the amendment.
If the final determination is that the amendment request involves a
significant hazards consideration, any hearing held would take place before the issuance of any amendment.
A request for a hearing or a petition for leave to intervene must be filed with the Secretary of the Commission, U.S. Nuclear Regulatory Commission, Washington, DC 20555, Attention:
Docketing and Services Branch, or may be delivered to the Commission's Public Document Room, the Gelman Building, 2l20 L Street, NW., Washington, DC 20555, by the above date.
Where petitions are filed during the last 10 days of the notice l
period, it is "requested that the petitioner promptly so inform the
~ A Commission by a toll-free telephone call to Western Union at I-(800) 248-5100 (in Missouri l-(800) 342-6700).
The Western Union operator should be given Datagram Identification Number N1023 and the following message
addressed to Theodore R. quay, Director, Project Directorate IV-3:
petitioner's name and telephone
- number, date petition was mailed, plant
- name, and publication date and page number of this FEDERAL REGISTER notice.
A copy of the petition should also be sent to the Office of the General
- Counsel, U.S. Nuclear Regulatory Commission, Washington, DC 20555, and to M. H. Phillips, Jr.,
Esq.,
Winston
& Strawn, 1400 L. Street, NW.,
Washington, DC 20005-3502, the licensee's attorney.
Nontimely filings of petitions for leave to intervene, amended petitions, supplemental petitions and/or requests for hearing will not be entertained absent a determination by the Commission, the presiding officer or the presiding Atomic Safety and Licensing Board that the petition and/or request should be granted based upon a balancing of the factors specified in 10 CFR 2.714(a)(1)(i)-(v) and 2.714(d).
For further details with respect to this action, see the application for amendment dated May 5,
- 1994, which is available for public.inspection at the Commission's Public Document Room, the Gelman Building, 2120 L Street, NW., Washington, DC 20555 and at the local public document room located at the Richland Public Library, 955 Northgate Street,
- Richland, Washington 99352.
Dated at Rockville,. Maryland, this
~0~
day of ~y y994.
FOR THE NUCLEAR REGULATORY COMMISSION.
~
- g. CcJ-c-h L. Mark Padovan, Acting Project Manager Project Directorate IV-3 Division of Reactor Projects - III/IV Office of Nuclear Reactor Regulation
A h
k
'~P
!I/
8 R1C Wp0 4y
,. i%
n'!
V~
~O
>>a*+~
DOCKET NO.
MEMORANDUMFOR:
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555 Ihy 10, 1994 Regulatory Publications Branch Division of Freedom of Information and Publications Services Office of Administration and Resources Management ISIRUUZIOif
" c't-Filp PD4-3 Reading D. Foster-Cureen If. Padovan FROM:
SUBJECT:
Office of Nuclear Reactor Regulation Maslungton %+lear Project No. 2 i One sIgned original of the Federal Regfsfer Notice identified below Is enclosed for your transmittal to the Office of the Federal Register for publication. Additional conformed copies (
5
) of the Notice are enclosed for your use.
Notice of Receipt of Application for Construction Permit(s) and Operating License(s).
Notice of Receipt of Partial Application for Construction Permit(s) and Facility fPRLI ense(s): Time for Submission of Views on Antitrust Matters.
Notice o Goltsideration of Issuance of Amendment to Facility Operating License. (Call with
.day insert date).
K Notice of Receiptlof Application for Facility License(s); Notice of Availability of Applicant's Environmental R
Notice of Consideration of Issuance of Facility License(s) and Notice of Opportunity for Hearing.
O Notice of Availabilityof NRC Draft/Final Environmental Statement.
Notice of Limited Work Authorization.
Notice of Availabilityof Safety Evaluation Report.
Notice of Issuance of Construction Permit(s).
Notice of Issuance of Facility Operating License(s) or Amendment(s).
I Order.
Exemption.
Notice of Granting Exemption.
',~ En)flronmental Assessment.
CJ
/
Notice of Preparation of Environmental Assessment.
Receipt, of Petition for Director's Decision Under 10 CFR 2.206.
Issuance of Final 6irector's Decision Under 10 CFR 2.206.
Other.
e call Paul 1Geene (504-1372) with tha 30 y~t ~~.
eport; and
Enclosure:
As. stated
Contact:
Phone:
ori!cm>
SURNAME&
OATE 5/10/94 NRC FORM 318 uo/eoI NRCM 0240 OFFICIAL RECORD COPY
r r
~
n I
n
)
ip,S RIC0
'18
+
0 Cy
-'~i 4
'n0 I
E Vl0 V/+
~O
+**4+
DOCKET NO.
MEMORANDUMFOFC t
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555 2!ay lu, 1994 Regulatory Publications Branch Division of Freedom of Information and Publications Services Office of Administration and Resources Management ISZRIBUZION ket File PDlI-3 Reading D. Foster-Cureen M. Padovan
SUBJECT:
Office of Nucjear Reactor Regulation I a~lungttrn hxlear Project?b.
2 One signed original of the Federal Register Notice Identified below Is enclosed for your transmittal to the Office of the Federal Register for publication. Additional conformed copies (
5
) of the Notice are enclosed for your use.
Notice of Receipt of Application for Construction Permit(s) and Operating License(s).
Notice of Receipt of Partial Application for Construction Permit(s) and Facility
~ense(s):
Time for Submission of Views on Antitrust Matters.
~ Notice of'Copsideratlon of Issuance of Amendment to Facility Operating License. (Call with day insert date).
K Notice of Receipt of Application for Facility License(s); Notice of Availability of Applicant's Environmental Report; and Notice of Consideration of Issuance of Facility License(s) and Notice of Opportunity for Hearing.
Notice of Availabilityof NRC Draft/Final Environmental Statement.
Notice of Limited Work Authorization.
Notice of Availabilityof Safety Evaluation Report.
Notice of Issuance of Construction Permit(s).
Notice of issuance of Facility Operating License(s) or Amendment(s).
Order.
Exemption.
Notice of Granting Exemption.
Environmental Assessment.
Notice of Preparation of Environmental Assessment.
Receipt of Petition for Director's Decision Under 10 CFR 2.206.
Issuance of Final Director's Decision Under 10 CFR 2.206.
0 Other.
call Paul Deem (504-1372) with tne XHiay insert date.
Enclosure:
As stated
Contact:
~Il~
Phone:
1 72 OF<!CE SURNAME>
5/10/94 NRC FORM S14 IIO/80I NRCM 0240 OFFICIAL RECORD COPY