Justification for Revised Tornado Design Criteria
ML17286B268
Person / Time
Site: Satsop
Issue date: 05/07/1991
From: Harness P, Laframboise W, Noble L
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
To:
Shared Package
ML17286B267 List:
References
NUDOCS 9106180002
Download: ML17286B268 (18)


Text

Justification for Revised Tornado Desi n Criteria prepereri iry:

W.L LaFramboise Principal Civil Engineer Reviewed by:

Q

< l<5 <~

D. Noble Supe isor Civil Engineering "Z. ~pl~/e F.D. Quinn Staff Meteorologist Approvedby:

> </Vr P.W. Harness Manager Mechanical Systems r

9i06iS0002 9i0607 PDR ADOCK 05000397 P

PDR

Justification for Revised Tornado Desi n Criteria The current tornado design criteria for WNP-2 is considerably more conservative than that required by the NRC or by probabilistic considerations of tornado hazards at the Hanford Site. These conservatisms result in unnecessary costly designs to provide protection for the current design basis tornado. This document provides the basis for revising the tornado design criteria for new work or for re-evaluations of existing structures to more realistically reflect the tornado hazards at WNP-2.

The current NRC tornado design criteria applicable to WNP-2 are summarized in Section 2.0, the current WNP-2 criteria are summarized in Section 3.0, and the proposed revisions to the current WNP-2 criteria are presented in Section 4.0. The technical justiTications for these revisions are provided in Section 5.0. The benefits ofimplementing these criteria revisions are summarized in Section 6.0.

2.0 NRC Tornado Desi n Criteria NRC tornado design criteria are defined in Regulatory Guide 1.76 [1] and Standard Review Plan (SRP) Sections 332 [2] and 35.1.4 [3]. These criteria have been established to provide an annual probability of exceedance of design loads of 1 x 10 7. To meet this objective, the NRC has defined in Regulatory Guide 1.76, three Tornado Intensity Regions which conservatively envelope the expected hazards within the respective regions. WNP-2 is in NRC Tornado Intensity Region IIIwhich has the least severe tornado loading requirements. Asummary ofNRC design requirements for Tornado Intensity Region IIIare provided in the followingsub-sections.

2.1 Tornado Wind and Differential Pressure Loads Regulatory Guide 1.76 specifies the followingtornado wind and differential pressure loads for Tornado Intensity Region III:

- loads resulting from a rotational wind velocity of 190 mph and a translational wind velocity of50 mph for a maximum horizontal velocity of240 mph

- a differential pressure load resulting from an external pressure drop of 15 psi at a rate of0.6 psi /sec.

2.2 Tornado Missile Loads SRP Section 35.1.4 specifies that structures and equipment subjected to tornado effects are to be evaluated for resistance to damage from the followingtornado generated missiles:

Missile Wei t lbs Dimensions C

Horizontal Impact VelocityforTornado Intensity Region III ft sec)

Wood Plank 6" Sch 40 Pipe 1" Steel Rod UtilityPole 12" Sch 40 Pipe Automobile 115 287 8.8 1124 750 3990 3.6" x 0.94' 12'ong 6.6" dia x 15'ong 1" dia x3'ong 135" dia. x35'ong 12.75" x 15'ong 16.4' 6.6' 43'90 33 26 85 23 134

These missiles are considered to strike surfaces in any direction. Vertical velocities are taken to be 70 percent of the horizontal velocities except the 1" steel rod which is assumed to have the same velocity in any direction. The utilitypole and the automobile are considered to strike surfaces at any elevation up to a maximum elevation of30 feet above the highest finished grade within05 miles of the plant. Allother missiles are considered to strike at any elevation above finished grade.

2.3 Load Combinations Based on SRP Section 332, total tornado loads resulting from wind loads, differential pressure loads, and tornado generated missiles are established from the followingequations:

W'= W W'= WP W'

Wm W'=W +05W W'

W~ + Wm W

W~ + 05 Wp + Willi where:

W' Total tornado load W~ = Tornado wind load W

Tornado differential pressure load P

W~

Tornado-generated missile load 3.0 Current WNP-2 Tornado Desi n Criteria Current WNP-2 tornado design criteria are considerably more conservative than required by the applicable NRC Regulatory Guides and Standard Review Plans. Current tornado wind speeds are based on NRC Regulatory Guide 1.76 [1] Tornado Intensity Region I requirements (where as noted above, WNP-2 is in Tornado Intensity Region III). In addition, the load combinations used to define the net loads resulting from wind loading and differential pressure are conservative with respect to those required by NRC SRP 33.2 [2]. Asummary of the current WNP-2 tornado design criteria is provided in the followingsub-sections.

3.1 Tornado Wind and Differential Pressure Loads AllSeismic Category I structures and equipment have been designed to withstand the effects of a design basis tornado defined by the followingconcurrent loads:

- loads resulting from a rotational wind velocity of300 mph and a constant translational wind velocity of 60 mph for a maximum horizontal velocity of360 mph

- a differential pressure load resulting from an external pressure drop of3 psi at a rate of 1.0 psi /sec.

The tornado wind velocities are considered to act horizontally and to be invariant with height.

Wind forces are modeled in terms ofstatic pressures based on ASCE paper No. 3269 [4J.

3.2 Tornado Missile Loads Allstructures and equioment subjected to tornado effects are evaluated for resistance to damage from tornado generated missiles. Missiles which are considered consist of the following:

Missile Wei t Ibs Dimensions Horizontal Impact Velocity ft sec UtilityPole 1" Steel Rod 1600 14" dia. x 35 ft long 241 8

1" diax3ftlong 259 These missiles are considered to strike surfaces in any direction. The utilitypole is considered to strike surfaces at any level up to a maximum level of30 feet above the highest finished grade within05 miles of the plant. The steel rod is considered to strike at any level above fmished grade.

An exception is made for the access door of the makeup water pump-house where the velocities of the above missiles are reduced to 85 ft/sec for the utilitypole and 26 ft/sec for the steel rod. These velocities are consistent with those of Revision 2 of SRP Section 35.1.4 for Tornado Intensity Region III. These reduced velocities were incorporated to reduce the thickness of the door to facilitate equipment replacement while still providing adequate missile protection by virtue of the compliance to the SRP.

3.3 Load Combinations The total tornado load resulting from wind loads, differential pressure loads, and tornado generated missiles is established as follows:

J W'

W~

W'= WP W'

Wm W'

+W W'

W~+ Wm W'

W~ + Wp + Wm where all terms are defined in Section 23.

4.0 Pro osed Revisions to the WNP-2 Tornado Desi n Criteria This section presents proposed revisions to the WNP-2 tornado design criteria for new work or re-evaluations of existing structures.

These criteria are based on extensive studies which define site specific tornado hazards for the Hanford area These criteria reduce unnecessary conservatism in the original WNP-2 design criteria and in the NRC criteria (which conservatively envelopes tornado hazards withinTornado Intensity Region II/while maintaining an annual probability of exceedance of design loads of 1 x 10 7. The technical justifications for these criteria are provided in the following section.

4.1 Tornado Wind and Differential Pressure Loads l

The followingtornado wind and differential pressure loads willform the design basis for new work or re-evaluations of existing structures at WNP-2.

- loads resulting from a rotational wind velocity of 135 mph and a translational wind velocity of45 mph for a maximum horizontal velocity of 180 mph

- a differential pressure load resulting from an external pressure drop of 0.65 psi at a rate of029 psi /sec.

4.2 Tornado Missile Loads The followingtornado generated missiles willform the design basis for new work or re-evaluations of existing structures at WNP-2:

Missile Wood Plank 6" Sch 40 Pipe 1" Steel Rod UtilityPole 12" Sch 40 Pipe Automobile Weight bs) 115 287 8.8 1124 750 3990 Dimensions 3.6" x 0.94' 12'ong 6.6" dia x 15'ong 1" diax3'long 13 dia. x35'ong 12.75" x 15'ong 16.4' 6.6' 43'orizontal Impact Velocity (ft/sec) see discussion below) 167 17 20 The utilitypole and the automobile are not considered to be credible missiles for wind velocities less than 200 mph for reasons presented in Section 5.2. The remaining missiles are considered to strike surfaces in any direction. Vertical velocities are taken to be 70 percent of the horizontal velocities except the 1" steel rod which is assumed to have the same velocity in any direction. Allmissiles are considered to strike at any elevation above finished grade. As noted in Section 5.2, the impact velocities of credible missiles are based on studies performed by EPRI [20] and are conservatively based on a maximum wind speed of240 mph.

The wood plank, 6" Sch 40 pipe, and the 12" Sch 40 pipe were not considered in the original WNP-2 tornado missile evaluations.

However, as a result of the substantially higher velocities (and weight of the utilitypole missile), the damage potential of the original WNP-2 design basis missiles is substantially more severe than that for these missiles. Therefore, the introduction of these missiles does not necessitate a re-evaluation of existing structures.

4.3 Load Combinations Load combinations for new work or evaluations of existing structures willbe based on Standard Review Plan Section 33.2 [2] as summarized in Section 23. (Note that 1/2 of the tornado differential pressure load is combined with the tornado wind load as specified in the SRP.)

5.0 Technical JUstification of Revisions in the Tornado Desi n Criteria WNP-2 is located in an extremely low tornado hazard area. The State ofWashington experiences, on the average, less than one tornado each year. Within a one hundred mile radius ofWNP-2, there have been only 21 reported tornadoes in the period from 1916 to 1980 [5]. Within the 570 square mile Hanford Site there has been only one reported tornado.

Astudy of the tornadoes in Washington, Oregon, and Idaho area was performed by Fujita [6] which indicated that tornadoes occur primarilyin "alleys". The location of these alleys with locations of reported tornadoes during the 20 year period from 1950 to=1969 is shown in Figure 5-1. Note that WNP-2 does not lie within any of the tornado alleys. These alleys are located in up-slope topography that we believe is necessary for tornado initiationwithin the Pasco Basin. The Hanford Site is essentially in a down slope region &om the Rattlesnake ridge making tornado initiation unlikely.

One ofthe first attempts at quantifying tornado hazards was made by Thorn [7]. Byutilizinga simple geometric interpretation ofprobability, the probability ofa tornado striking any given location is defmed by the followingequation:

P(s) = an/A where:

P(s) a n

A the probability that a tornado willstrike a given location the mean tornado damage path area in square miles the mean number of tornadoes per year the area of the local region in which the mean number of tornadoes was reported in square miles By assuming independence between tornado wind speed and tornado strike probabilities, Markee, Beckerley, and Sanders expanded upon the Thorn model in Wash-1300 [8] to develop an interim regional tornado design criteria which currently forms the basis of Regulatory Guide 1.76. In their model, the probability of exceeding a given tornado wind speed is determined I'rom the following equation:

P( v > V ) = P>(V ) P(s) where:

Pt(V~)

the probability of a tornado having wind speeds in excess ofVo. This probability is referred to as the tornado intensity distribution P(s)

= the probability of a tornado strike as defined by the Thorn model Wash-1300 Methodofo The process employed in Wash-1300 to establish design tornado wind speeds for each Tornado Intensity Region is outlined below:

- Tornado strike probabilities were determined for each five degree square of latitude and longitude in the contiguous United States based on a mean tornado damage path area of2.82 square miles established by Thorn [7] for tornadoes occurring in a ten year period in Iowa.

The mean number of tornadoes within each five-degree square was determined using 13 years of tornado occurrence records compiled by Pautz [9].

- Based on data developed by NOAAchmatologists (Ref [10] and [11]) for tornadoes which occurred within the contiguous United States during 1971 and 1972, tornado wind speed exceedance probabilities ( P<(Vg ) were established independent ofgeographic location and tornado damage path area.

- For each five degree square of latitude and longitude, a tornado wind speed was selected to provide an annual probability of exceedance of 1 x 10 7. Based on these wind speeds, design tornado wind speeds were established for each of the NRCs Tornado Intensity Regions.

Conservatlsms in the Wash-1300 Methodolo The Wash-1300 tornado criteria is recognized as being conservative, and as is stated in Wash-1300, it was considered at the time ofits development as an interim criteria until more realistic criteria could be developed.

Major sources of conservatism ofthe Wash-1300 criteria as they relate to the Hanford area are as follows:

A.

if

- The mean path area for tornadoes occurring within the Pacific Northwest is considerably less than the 2.82 square miles assumed in Wash-1300. As noted above, this path area was based on tornadoes occurring in Iowa. As an example, in a study performed for the Jersey Nuclear Fuel Facility (now referred to as the Advanced Nuclear Fuels Facility) in Richland WA, Jaech

[12] determined that the mean path area for tornadoes occurring withinWashington, Oregon, and Idaho during 1950 to 1969 to be OAS square miles.

- Tornado wind speeds within the Columbia Basin are considerably lower than the national average.

For example, based on the data reported in [6] for the 20 year period from 1950 to 1969, within the region east of the Cascade Mountains and North of the 45'" parallel, the highest reported tornado intensity was F2 (wind speeds 113 - 157 mph). During this period, there were only four reported F3 tornadoes (wind speeds 158 - 206) withinWashington, Oregon and Idaho. Two of these tornadoes occurred in the Portland/ Vancouver area, one occurred in the Seattle/ Tacoma area, and the other occurred at the Oregon/ Idaho border near Ontario, Oregon.

- The Wash-1300 methodology assumed that the maximum wind speed of a tornado occurs uniformlyover the entire damage area. However, wind speeds vary across and along the path of a tornado. For example, based on a simple Rankine vortex model of tornado winds and data obtained from the Super Outbreak ofTornadoes ofApril3-5, 1974 [13], McDonald [14]

established that for a F3 tornado, only 17 percent of the damage area experiences winds that are in F3 range.

Refined Tornado Hazard Models Substantial refinements have been made by Abbey and Fujita [15] and by McDonald [14] in the methodology for predicting tornado hazards since the time the Wash-1300 study was performed. The refinements incorporated in these hazard models are summarized below:

- a larger database of reported tornadoes is available for statistical analyses than was available at the time the Wash-1300 study was performe'd

- estimates of the number of unreported tornadoes are made and are included in the hazard models based on population density and land use

- regionalized path area - intensity and occurrence frequency - intensity relationships are developed directly from reported data and estimated unreported tornadoes

- the variation ofwind speed across and along the tornado path are explicitlyaccounted for in the revised models The Department ofEnergy (DOE) through Lawerence Livermore National Laboratory contracted Fujita and McDonald to perform independent tornado hazard evaluations for the various DOE nuclear related sites using their tornado hazard models. The results of this effort were pubEshed in 1985 [16]. As a result of the low tornado hazard for the Hanford area, the maximum horizontal wind speeds derived independently by Fujita and McDonald were 179 mph and 177 mph respectively for an annual probability of exceedance of 1 x 10 7. These evaluations form the basis for selecting the revised maximum wind speed of 180 mph for WNP-2.

In addition, the American National Standards Institute has proposed a "Standard for Tornado and Extreme Wind Characteristics at Nuclear Power Plant Sites" [24] which estimates tornado wind speeds of 180 mph corresponding to an annual probability ofexceedance of 1x 10 7 for the region west of the Rocky Mountains. This result provides additional support for the selection of a design maximum wind speed of 180 mph for WNP-2.

Pacific NorthwestLaborato Tornado Climatolo Stvd Pacific Northwest Laboratory (PNL) [22] compiled data on the characteristics of tornadoes occurring in the contiguous United States for the period from January 1, 1954, through December 31, 1983 based on reported tornadoes contained in the National Severe Storms Forecast Center tornado data base. Statistical analysis of these data were performed to estimate tornado wind speeds for each 5 degree square of latitude and longitude with10, 10, and 10 7 probabilities of exceedance per year for both mean and 90 percentile confidence limits. Since design wind speeds have traditionally been based on a mean probability of exceedance of 10 7 (i.e.,WASH-1300 [8], McDonald [14], and the Department of Energy [16]), the results presented below are based on this value.

The statistical models used in the PNL analysis were similar to those used in the WASH-1300 study with the followingexceptions:

- rather than assuming a mean tornado path area of2.82 square miles, the PNL study calculated expected mean tornado path areas in each 5 degree square by fittinga log-normal probability distribution to the recorded tornadoes within the square and integrating over the distribution to establish the expected mean path area. The computed expected mean values are generally substantially smaller than 2.82 square miles.

- in Wash-1300, tornado wind speed exceedance probabilities ( P<(VO) ) are established for the entire contiguous United States from the relative frequencies of each tornado intensity class (i.e., F-scale) and are assumed to be in the form of a log-normal probability distribution. In the PNL study, tornado wind speed exceedance probabilities are more realistically based on relative frequencies of the total affected area of each tornado intensity class and are based on a Weibull probability distribution. In addition, the PNL study develops independent tornado intensity distributions of western and eastern regions of the contiguous United States.

The PNL studies result in significantly lower tornado wind speeds than that predicted by WASH-1300.

Tornado wind speeds for a probability of exccedance of 10- for the 5 degree square centered at 475 North, 12Z5 West is 186 mph and for the 5 degree square centered at 475 North, 1175 West is 192 mph (note that WNP-2 is located in the latter square adjacent to the border of these two squares).

The slightly higher wind speeds developed by PNL than by Fujita and McDonald can be attributed to the differences in the methodology and the followingconservatisms in the PNL approach:

- the PNL approach does not account for the variation ofwind speed across and along the tornado path. As noted above, an F3 tornado willhave only 17 percent of the damage area experiencing winds in the F3 range. It is estimated that approximately 36 percent of the path length and 48 percent of the path width willbe in the F3 range. In the PNL study, it is reasoned that the conservatism of neglecting variations along the path length willoffset potential miss-classification errors of violent tornadoes (i.e., reporting tornadoes with F-scales of 4 and 5 as having a lower intensity) as reported by Twisdale et aL [23]. This compensation should be overly cons'ervative west of the Rocky Mountains since there have been only rare reports of violent tornadoes in this region. (Fujita [17] reports only 3 violent tornadoes in the period form 1916 to 1977 all ofwhich were located in the Imperial Valley of southern California. No violent tornadoes were reported west of 1050 west in the period from 1953 to 1983 [22]). In any case, neglecting variations across the path width as is performed in the PNL study willresult in an over estimate of areas effected by peak tornado winds.

- expected tornado path areas are calculated by fittinga log-normal probability distribution to the recorded data and integrating over the distribution to establish the expected mean path area. This approach would provide a more accurate estimate of the mean than a simple arithmetic average provided that the probability distribution accurately models the data. As

noted in the PNL report, the accuracy of a log-normal distribution is open to question and a Weibull distribution may be a more accurate modeL Based on data contained in Appendix A of the PNL report, the use of a log-normal distribution potentially results in a over prediction of the expected area by a factor of L5 to 2.0. For the Pacific Northwest, this would result in an over prediction ofwind speeds by approximately 10 mph.

As a result of these considerations, the PNL study supports the proposed design tornado wind speed of 180 mph. The slightly higher wind speeds predicted by the PNL study are a result of the different methodologies and the above conservatisms.

5.1 Tornado Vend and ONerential Pressure Desi n Parameter Tornado wind and differential pressure design parameters can be established as a function of the maximum horizontal wind speed.

For this purpose, the Fujita DBT-77 [17J tornado wind field model willbe used. In this model, the translational and rotational wind velocities are determined as follows:

V

= 1/4V V~- 3/4 Vm~

where:

V~

= Rotational Wind Velocity V~~

'Maximum Horizontal Wind Velocity V,

= Translational Wind Velocity Utilizingthese equations and a maximum horizontal wind speed of 180 mph, the resulting rotational wind velocity is 135 mph and the resulting translational wind velocity is 45;mph.

The maximum differential pressure is established based on the rotational component of the wind velocity from the followingequation:

p ~p V2 where p ~ mass density of air For a maximum rotational wind velocity of 135 mph, the above equations result in a maximum differential pressure of0.65 psi. The rate of pressure change is established from the followingequation:

dp/dt = p V2~ ( V,/ Ro )

where Ro radius ofmaximum winds Based on Regulatory Guide L76 [1), R is assumed to be L% ft (note, this value is conservative with respect to the Fujita DBT-77 model). Utilizingthis value, the rate of pressure change is 029 psi/sec. Note that these values appear to be very conservative considering the almost total lack ofdamage from northwestern tornadoes.

6.2 Tornad Missiles The tornado missile velocities incorporated in the revised WNP-2 tornado design criteria are based on the extensive research sponsored by EPRI ([20] and [21]) to establish more realistic tornado missile criteria. Original NRC tornado missile criteria were developed by the National Bureau ofStandards (NBS) [19]. Major improvements in the EPRI tornado missile analysis methodology are outlined below:

- The EPRI tornado wind field model more realistically considers near ground tornado winds and models variations of wind velocities as a function of height. The NBS evaluations assume a simple Rankine vortex model of tornado winds which defines wind speeds strictly as function of radius from the center of the tornado. In the NBS evaluations, the missiles are conservatively assumed to be introduced into the wind field at an initialelevation of40 meters. As a result, during their free fall, the missiles are subject to tornado winds which are invariant with height. The missile velocities in the revised WNP-2 criteria are also based on the conservative assumption of an initialheight of40 meters.

However, using the more refined EPRI wind Geld model, the forcing function applied to the missiles considers expected variations with height which reduces in magnitude as the missile approaches the ground.

- The NBS flight model assumes that the missile is acted on strictly by drag forces.

Liftand tumbling elfects are neglected.

Drag - Area coefflcients are assumed to be an average of the analytically derived coefficients for three orthogonal directions of the missile. In the EPRI flight model, all 6 degrees of freedom of missile flight are explicitlyincluded in the model. Hight parameters and drag coefficients were experimentally determined from wind tunnel testing.

The tornado missile velocities incorporated in the revised WNP-2 tornado design criteria are conservatively based on a maximum wind speed of240 mph using the EPRI wind field and flightmodels. Similar to the NBS evaluations, the initialheight of the missiles is conservatively assumed to be 40 meters.

An exception is made for the automobile and utilitypole missiles. Based on analyses performed using the Institute for Disaster Research (IDR)TMTCcomputer program [18]

reported in [16], these missiles willnot be picked-up or sustained by the wind ifthe wind speed is less than 200 mph.

6.3 Load Combinations The load combinations specified in the revised criteria are identical to those in SRP Section 332. These load combinations recognize the fact that peak wind and pressure differential loads do not occur simultaneously as was conservatively assumed in the original WNP-2 criteria.

6.0 Benefits of lm lementin the Revised Tornado Desi n Criteria By implementing the proposed revisions, the tornado design criteria willmore realistically reflect the tornado hazards at WNP-2 while maintaining the NRCs objective of providing an annual probability ofexceedance of design loads of 1 x 10 7. These revisions willresult in more realistic wind velocities, differential pressure loads, missile velocities, and load combinations.

These revisions are an integral part ofthe Supply System's efforts of hard bolting the Reactor Building roof to improve its reliability 10

for differential pressure and straight wind loads [+. The revised criteria may also beneGt in the resolution of a concern regarding the potential hazard of a tor'nado missile induced failure of the nitrogen tank used to provide containment inerting [+. The proposed revisions willalso bene6t the design of exterior structures and components which must consider postulated tornado effects.

l,

7.0 Referen e

[1]

[2]

[3]

[4]

[5]

[6]

[7]

[8]

[9]

[101

[11]

[12]

[13]

[14]

[16]

[17]

[18]

[19]

[20]

[21]

[22]

[23]

US. Nuclear Regulatory Commission Regulatory Guide 1.76, "Design Basis Tornado for Nuclear Power Plants,", Washington D.CApril1974 U.S. Nuclear Regulatory Commission Standard Review Plan Section 332, "Tornado Loadings,"

NUREG-0800, Rev 2Washington D.C., July 1981 U.S. Nuclear Regulatory Commission Standard Review Plan Section 33.1.4, "Missiles Generated by Natural Phenomena,"

NUREG4800, Rev 2, July 1981, Washington D.C.

ASCE Paper No. 3269,

%find Forces on Structures," Transactions of the American Society ofCivil Engineers, VoL 126, Part II, 1961.

Stone, WAThorp,J34., Gifford, OZHoitinkDL, "Climatological Summary for the Hanford Area", Prepared for the U.S. Department ofEnergy under Contract DE-AC06-76RLO 1830 by Pacific Northwest Laboratory Operated by Battelle iVIemorial Institute, PNL<22-UC-11.

Fujita, T.T., Estimate ofMaximum Wind Speeds ofTornadoes in Three Northwestern States",

S~i Research Paper No. 92, The University of Chicago, December 1970.

Thorn, H.C.S., "Tornado Probabilities," Monthly Weather Review, VoL 91, pp 730-736, 1963.

Markee, E.H., Beckerley, J.G., and Sanders, KZ., "Technical Basis for Interim Regional Tornado Criteria," WASH-1300, U.S. Atomic Energy Commission, Office of Regulation, Washington, D.C.,

1974.

Pautz, MZ., ed., "Severe Local Storm Occurrences 1955-1967," ESSA Technical Memo, WBTM FCST 12, OfQce of Meteorological Operations, Silver Springs, MD.

Fujita, T.T., "F-Scale Classification of 1971 Tornadoes," SMRP Research Paper No. 100, 1972.

Fujita, T.T., Pearson, A. D., "Results ofFPP Classification of 1971 and 1972 Tornadoes," Eight Conference on Severe Local Storms, Denver, CO, 1973.

Jaech, JJ.., Statistical Analysis ofTornado Data for Three Northwestern States," Jersey Nuclear Co.,

1970.

Fujita, T.T., "Super Outbreak Tornadoes ofAprilM, 1974," Department of the Geophysical Sciences, The University of Chicago, Chicago, II1975.

iMcDonald, J.R., "AMethodology for Tornado Hazard Probability Assessment," Institute for Disaster Research, Texas Tech University, Prepared for U5. Nuclear Regulatory Commission,.liUREG/CR-3058, 1983.

Abbey, RX., Fujita, T.T fhe DAPPLE Method for Computing Tornado Hazard Probabilities ReGnements and Theoretical Considerations," Preprints of the Eleventh Conference on Severe Local Storms, American Meteorological Society, Boston, MA,1979.

Coats, D.W., Murray, R. C"Natural Phenomena Hazards Modeling Project: Extreme Wind/Tornado Hazard Models for Department ofEnergy Sites," UCRL-53526, Rev 1, Lawrence Livermore National Laboratory, Livermore CA, August 1985.

Fujita, T,T. "Workshop ofTornadoes and High Winds for Engineering Applications," SiiRP No. 165, Department of the Geophysical Sciences, The University of Chicago, Chicago, II1978.

McDonald, J.R"Flight Characteristics ofTornado Generated Missiles," Institute for Disaster Research, Texas Tech University, Lubbock, Texas, 1975.

Simiu E, and Cordes, M"Tornado-Born Missile Speeds", NBSIR 76-1050, Institute for Basic Standards, National Bureau ofStandards, Washington D.C., April1976.

~ind Field and Trajectory iModels forTornado-Propelled Objects," EPRI Report EPRI NP-748, Electric Power Research Institute, Palo Alto, CA, May 1978.

Vend Field and Trajectory Models forTornado-Propelled Objects," EPRI Report EPRI iiP-2898, Electric Power Research Institute, Palo Alto, CA, March 1983.

Ramsdeil, J.VAndrews, G.LTornado Climatology of the Contiguous United States, Pacific Northwest Laboratory Operated by Batteile Memorial Institute, Prepared for U5. Nuclear Regulatory Commission, NUREG/CR~1, 1986.

Twisdale, LADunnWLLew,S.TDavis, TLHsu, J.Cand Lee, S.T"Tornado Missile Risk Analysis Appendices", Electric Power Research Institute, Palo Alto California, EPRI-769.

[24] "Standard for Estimating Tornado and Extreme Wind Characteristics at Nuclear Power Sites,"

ANSI/ANS-23-1983, American Nuclear Society, La Grange Park, Illinois.

f~ Letter, C2vf. Powers, Supply System to NRC Document Control Desk, "Licensee Event Report No.

88-70," March 16, 1988.

[26] Letter, C2vf. Powers, Supply System to'NRC Document Control Desk, "Licensee Event Report No.

8940141," March 27, 1989.

4

~

~

FIGURE 5-1 ATI N F T RNAD ALLEY WITHREP RTED TORNAD E

FR M 1 50 TO 19N Reference WNP-2 FSAR ICC I

IC4

.I v

<44fw V

j X

I

'i r I

4 I ~OE40 f ~

ICD i: I"

~ C

~DSOOS

<<<S4lsf<TOII ~+I t l t fV

~

I r/4foto

P~

II4

)

l f

IIC I

S

~Ca I ID SO 4b

<C

<4g

~

4<elf<

fr Y/

IC4 g P a

Q<orogd V

ICC PRCCiPII I

I J.

I

~rr

(

4 J

L II4 r

V I

l l

vl IIC 44 4C IOO 0