INSTRUMENTATION ACCID NT MONITORING IHSTRUMEHTATION LIMITING CONDITION FOR OPERATiON 3.3.7.5 The accident monitoring instrumentation channels shown in Table 3.3.7.5-1 shall be OPERABLE.

APPLICABILITY: As shown in Table 3.3.7.5-1.

ACTION:

inoperable, the ACTION required by Table 3.3.7.5-1. ~

With one or more accident monitoring instrumentation channels Pro Q(5ignPS 0 ake g)kg) Q(~fifpg

.ie ~~A .p~il~d/~

SURVEILLANCE REQUIREMENTS

4. 3. 7. 5 Each of the above required accident m ing instrumentation channels shall be demonstrated OPERABLE by pe ance of the CHANNEL CHECK and CHANNEL CALIBRATION operations at'e f ncies shown in Table 4. 3. 7. 5-1.

WASHINGTON NUCLEAR - UNIT 2 3/4 3"70 9004260261 9004iS PDR ADOCK 05000397 P PDC