(~ DUKE

~ ENERGY~

Serial: RA-17-0045 October 12, 2017 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 CATAWBA NUCLEAR STATION, UNITS 1 AND 2 KELVIN HENDERSON Senior Vice President Nuclear Corporate 526 S. Church Street, EC-07H Charlotte, NC 28202 980-373-1295 Kelvin.Henderson@duke-energy.com 10 CFR 50.90 DOCKET NOS. 50-413 AND 50-414 I RENEWED LICENSE NOS. NPF-35 AND NPF-52 MCGUIRE NUCLEAR STATION, UNITS 1 AND 2 DOCKET NOS. 50-369 AND 50-370 I RENEWED LICENSE NOS. NPF-9 AND NPF-17 H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 DOCKET NO. 50-261 I RENEWED LICENSE NO. DPR-23

SUBJECT:

SUPPLEMENT: APPLICATION TO REVISE TECHNICAL SPECIFICATIONS TO ADOPT TSTF-529, "CLARIFY USE AND APPLICATION RULES" Pursuant to 10 CFR 50.90, Duke Energy Progress, LLC, and Duke Energy Carolinas, LLC, collectively referred to henceforth as "Duke Energy," submitted a proposed amendment to Technical Specifications (TS) Section 1.3 and Section 3.0 for Catawba Nuclear Station (CNS),

Units 1 and 2; McGuire Nuclear Station (MNS), Units 1 and 2; H. B. Robinson Steam Electric Plant (RNP), Unit No. 2 regarding Limiting Condition for Operation (LCO) and Surveillance Requirement (SR) usage. These changes were consistent with NRC-approved Technical Specifications Task Force (TSTF) Traveler TSTF-529, "Clarify Use and Application Rules,"

Revision 4.

During NRC staff review of the application to adopt TSTF-529, they identified that the TS pages (Mark-up) for LCO 3.0.4 for CNS, MNS and RNP did not include capitalization for "specification" and "specifications" consistent with TSTF-529 and the model SE. Attachment 2 provides the revised TS pages (Mark-up) that show the proposed change for CNS, MNS and RNP. The retyped TS pages will be provided to the NRC immediately prior to issuance of the approved amendments.

This submittal contains no regulatory commitments.

In accordance with 10 CFR 50.91, a copy of this supplement, with Attachment 2, is being provided to the designated North Carolina and South Carolina officials.

If you should have any questions regarding this submittal, or require additional information, please contact Art Zaremba, Manager-Nuclear Fleet Licensing, at (980)373-2062.

U.S. Nuclear Regulatory Commission RA-17-0045 Page 2 I declare under penalty of perjury that the foregoing is true and correct. Executed on October 12, 2017.

Sincerely,

£PP.

Kelvin Henderson Senior Vice President - Nuclear Corporate

Attachment:

2. Proposed Technical Specification Changes (Mark-up)

U.S. Nuclear Regulatory Commission RA-17-0045 Page 3 cc (with Attachments):

C. Haney, USNRC Region II - Regional Administrator J. D. Austin, USNRC Senior Resident Inspector-CNS G. A. Hutto, USN RC Senior Resident Inspector - MNS G. R. Eatmon, USN RC Senior Resident Inspector - RNP D. Galvin, NRR Project Manager - RNP M. Mahoney, NRR Project Manager - CNS and MNS A. Gantt, Chief, Bureau of Radiological Health (SC)

A. Wilson, Attorney General (SC)

W. L. Cox, Ill, Section Chief, North Carolina Department of Health and Human Services, RP Section (NC)

S. E. Jenkins, Manager, Radioactive and Infectious Waste Management (SC) to RA-17-0045 Proposed Technical Specification Changes (Mark-up)

LCO Applicability 3.0 3.0 LCO APPLICABILITY (continued)

LCO 3.0.4 LCO 3.0.5 LCO 3.0.6 When an LCO is not met, entry into a MODE or other specified condition in the Applicability shall only be made:

a.

When the associated ACTIONS to be entered permit continued operation in the MODE or other specified condition in the Applicability for an unlimited period of time; or

b.

After performance of a risk assessment addressing inoperable systems and components, consideration of the results, determination of the acceptability of entering the MODE or other specified condition in the Applicability, and establishment of risk management actions, if appropriate (exceptions to this Specification are stated in the individual Specifications); or ff appropriate; exceptions to this Speoifioation are stated in the individual Speoifioations; or

c.

When an allowance is stated in the individual value, parameter, or other Specification.

This Specification shall not prevent changes in MODES or other specified conditions in the Applicability that are required to comply with ACTIONS or that are part of a shutdown of the unit.

Equipment removed from service or declared inoperable to comply with ACTIONS may be returned to service under administrative control solely to perform testing required to demonstrate its OPERABILITY or the OPERABILITY of other equipment. This is an exception to LCO 3.0.2 for the system returned to service under administrative control to perform the required testing to demonstrate OPERABILITY.

When a supported system LCO is not met solely due to a support system LCO not being met, the Conditions and Required Actions associated with this supported system are not required to be entered.

Only the support system LCO ACTIONS are required to be entered.

This is an exception to LCO 3.0.2 for the supported system. In this event, additional evaluations and limitations may be required in accordance with Specification 5.5.15, "Safety Function Determination Program (SFDP)." If a loss of safety function is determined to exist by this program, the appropriate Conditions and Required Actions of the LCO in which the loss of safety function exists are required to be entered.

(continued)

Catawba Units 1 and 2 3.0-2 Amendment Nos. 235/231

LCO Applicability 3.0 3.0 LCO APPLICABILITY (continued)

LCO 3.0.4 LCO 3.0.5 LCO 3.0.6 When an LCO is not met, entry into a MODE or other specified condition in the Applicability shall only be made:

a.

When the associated ACTIONS to be entered permit continued operation in the MODE or other specified condition in the Applicability for an unlimited period of time; or

b.

After performance of a risk assessment addressing inoperable systems and components, consideration of the results, determination of the acceptability of entering the MODE or other specified condition in the Applicability, and establishment of risk management actions, if appropriate (exceptions to this Specification are stated in the individual Specifications); or if appropriate; exceptions to this Specification are stated in the individual Specifications; or

c.

When an allowance is stated in the individual value, parameter, or other Specification.

This Specification shall not prevent changes in MODES or other specified conditions in the Applicability that are required to comply with ACTIONS or that are part of a shutdown of the unit.

Equipment removed from service or declared inoperable to comply with ACTIONS may be returned to service under administrative control solely to perform testing required to demonstrate its OPERABILITY or the OPERABILITY of other equipment. This is an exception to LCO 3.0.2 for the system returned to service under administrative control to perform the required testing to demonstrate OPERABILITY.

When a supported system LCO is not met solely due to a support system LCO not being met, the Conditions and Required Actions associated with this supported system are not required to be entered. Only the support system LCO ACTIONS are required to be entered. This is an exception to LCO 3.0.2 for the supported system. In this event, additional evaluations and limitations may be required in accordance with Specification 5.5.15, "Safety Function Determination Program (SFDP)." If a loss of safety function is determined to exist by this program, the appropriate Conditions and Required Actions of the LCO in which the loss of safety function exists are required to be entered.

When a support system's Required Action directs a supported system to be declared inoperable or directs entry into Conditions and Required Actions for a supported system, the applicable Conditions and Required Actions shall be entered in accordance with LCO 3.0.2.

(continued)

McGuire Units 1 and 2 3.0-2 Amendment Nos. 221/203

\\..J

\\..._,/'

LCO Applicability 3.0 3.0 LCO APPLICABILITY LCO 3.0.4 (continued)

LCO 3.0.5 LCO 3.0.6

a. When the associated ACTIONS to be entered permit continued operation in the MODE or other specified condition in the Applicability for an unlimited period of time. or
b. After performance of a risk assessment addressing inoperable systems and components. consideration of the results. determination of the acceptability of entering the MODE or other specified condition in the Applicability. and establishment of risk management actions.
  • e~eept;efls te th;s Spee;f;eat;en ere ~tated ~l!fte""'tftlH¥'HHtitt Spee;f;eatie"s, er if appropriate (exceptions to
c. When an allowance is sta~e~ in.the in this Specification are stated parameter. or other Spec1f1cat1on.

in the individual Th. S

.f. t' h 11 t

t h

Specifications); or is pec1 ica ion s a no preven c an,a.-........,.........,.........,,.......,..........,,,,,...,r----"'T""'""

specified conditions in the Applicability that are required to comply with ACTIONS or that are part of a shutdown of the unit.

Equipment removed from service or declared inoperable to comply with ACTIONS may be returned to service under administrative control solely to perform testing required to demonstrate its OPERABILITY or the OPERABILITY of other equipment. This is an exception to LCD 3.0.2 for the system returned to service under administrative control to perform the testing required to demonstrate OPERABILITY.

When a supported system LCD is not met solely due to a support system LCO not being met. the Conditions and Required Actions associated with this supported system are not required to be entered. Only the support system LCD ACTIONS are required to be entered. This is an exception to LCO 3.0.2 for the supported system. In this event, additional evaluations and 1 imitations may be required in accordance with Specification 5.5.15, "Safety Function Determination Program CSFDP)." If a loss of safety function is determined to exist by this program, the appropriate Conditions and Required Actions of the LCD in which (continued)

HBRSEP Unit No. 2 3.0*2 Amendment No. m, f6S