Application for Amend to License NPF-21,changing Tech Spec Table 3.3.7.5-1 Re Accident Monitoring Instrumentation Under Emergency Conditions.Fee Paid
ML17284A463
Person / Time
Site: Columbia 
Issue date: 07/25/1988
From: Sorensen G
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML17284A464 List:
References
GO2-88-161, TAC-68897, NUDOCS 8808050091
Download: ML17284A463 (7)


Text

C CELERATZD DISFRIBUTJON DEMONSTRATION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:8808050091 DOC.DATE: 88/05/25 NOTARIZED: YES DOCKET FACIL:50-397 WPPSS Nuclear Project, Unit 2, Washington Public Powe 05000397 AUTH.NAME AUTHOR AFFILIATION TERRY,C.D.

Niagara Mohawk Power Corp.

RECIP.NAME RECIPIENT AFFILXATION Document Control Branch (Document Control Desk)

SUBJECT:

Application for amend to License NPF-2l,changing Tech Spec Table 3.3.7.5-1,accident monitoring instrumentation.

DISTR1BUTION CODE:

AOOID COPIES RECEIVED:LTR g ENCL Q SIZE:

TITLE: OR Submittal:

General Distribution NOTES RECIPIENT ID CODE/NAME PD5 LA SAMWORTH,R COPIES LTTR ENCL 1

0 1

1 RECXPIENT COPIES

,'D",CODE/NAME*,) "I LTTR ENCL PD5 PD 5'

I A

INTERNAL: ACRS NRR/DEST/ADS 7E NRR/DEST/ESB 8D NRR/DEST/RSB 8E NRR/PMAS/ILRB12 OGC/HDS2 RES/DSIR/EIB EXTERNAL: LPDR NSIC 6

6 1

1 1

1 1

1 1

1 1

0 1

1 1

1 1

1 ARM/DAF/LFMB NRR/DEST/CEB 8H NRR/DEST/MTB 9H NRR/DOEA/TSB 11 O

STRACT G FILE 01 NRC PDR 1

0 1

1 1

1 1

1 1

1 1

1 1

1 S

1' TOTAL NUMBER OF COPIES REQUIRED:

LTTR 28 ENCL 25

WASHINGTON PUBLIC POWER SUPPLY SYSTEM F.O. Box 968

~ 3000 George Washington Way

~ Richland, Washington 99352 G02-88-161 July 25, 1988 Docket No. 50-397 Nuclear Regulatory Commission Attn:

Document Control Desk Mail Station Pl-137 Washington, D.C.

20555 Gentlemen:

Subject:

NUCLEAR PLANT NO. 2 OPERATING LICENSE NPF-21, RE(}VEST FOR AMENDMENT TO TECHNICAL SPECIFICATION TABLE 3.3.7.5-1 (ACCIDENT MONITORING INSTRUMENTATION) UNDER EMERGENCY CIRCUMSTANCES In accordance with the Code of Federal Regulations, Title 10, Parts 50.90, 2.101, and 50.91(a)(5),

the Supply System hereby submits a request for amendment to the WNP-2 Technical Specifications on an emergency basis as provided for in the regulations.

Specifically, the Supply System is requesting that notes be added to Tables 3.3.7.5-1, Accident Monitoring Instrumentation, and 4.3.7.5-1 Accident Monitoring Instrumentation Surveillance Requirements to allow a single acoustic monitor to be inoperable until the plant shuts down for its next scheduled refueling outage or until the first forced outage of sufficient duration to effect repair, whichever occurs first (see attached).

Action 80.a for Technical Specification Table 3.3.7.5-1, Accident Monitoring Instrumentation, requires that the plant be shut down if an inoperable indicator channel is not restored to operable status within seven (7) days.

Due to apparent failure of the Acoustic Monitor (Safety/Relief Valve Position Indicator, Item

10) for MS-RV-1B, the Supply System entered the seven day LCO (Action 80.a) at 1638 hours0.019 days <br />0.455 hours <br />0.00271 weeks <br />6.23259e-4 months <br /> on July 20, 1988.

It has been determined that the plant will be required to be shut down and cooled down in order to repair/replace this acoustic

monitor, unless an amendment is granted to allow the Supply System to continue to operate until either the next forced outage or the next scheduled outage (R-4).

8808050091 880725 PDR ADOCK 05000397 P

PDC po i l f 50

~

II

'A u

Page Two NUCLEAR PLANT NO. 2 OPERATING LICENSE NPF-21, RE()UEST FOR AMENDMENT TO TECHNICAL SPECIFICATION TABLE 3.3.7.5-1 (ACCIDENT MONITORING INSTRUMENTATION) UNDER EMERGENCY CONDITIONS The operability of the accident monitoring instrumentation is based on providing assurance that sufficient information is available on selected plant parameters (e.g.,

SRY position indication) to monitor and assess important variables following an accident.

TMI Action Plan Item II.D.3 "Direct Indication of Relief and Safety-valve Position" requires that "Reactor coolant system relief and safety valves shall be provided with a positive indication in the control room derived from a reliable valve-position detection device or a reliable indication of flow in the discharge pipe."

The technical specifications for NNP-2 require two instrumentation channels for providing this information on valve position.

One channel utilizes an acoustic monitor.

The second channel utilizes thermocouples to detect a temperature increase indicative of flow past the valve.

The loss of position indication for one of the eighteen (18) Safety/Relief Valves does not reduce the capability of the SRV to perform its intended function, nor does it prevent accurate determination of the position of the associated SRY.

The following mitigating and compensatory factors provide assurance that the valve position is adequately monitored:

I)

Tail'ipe temperature indication, is monitored and recorded.

An increase in temperature 'ould indicate that the valve is open, and steam was entering the suppresssion pool via the tail pipe.

This indication has remained capable of indicating valve actuation since the failed monitor was identified.

Channel checks of the temperature recorder are currently performed monthly per LCO 3/4;3.7.5.

Until MSRV-1-B is declared

operable, the tail pipe temperature surveillance will be performed daily instead of monthly.

(See proposed change to Table 4.3.7.5-1 attached.)

A control room annunciator is available that alarms on high tail pipe temperature (greater than 250 F).

An annunciator response procedure addressing the tail pipe temperature alarm will be revised to uniquely identify appropriate actions for MS-RY-IB.

2)

Suppression Pool temperature indication is available, and is set to alarm at 85 F.

An increase in suppression pool temperature would indicate an open SRY.

3)

Suppression Pool level indication is available, and is set to alarm at

+0.5"/-1" of Normal Level (466'3").

An increase in suppression pool level would indicate an open SRV.

4)

Other plant parameters are affected by an SRV actuation and are available as confirmation.

Examples are main turbine governor valve position indication

change, generator output
change, main tur bine steam flow change and the resultant reactor pressure perturbation.

Page Three NUCLEAR PLANT NO. 2 OPERATING LICENSE NPF-21, REQUEST FOR AMENDMENT TO TECHNICAL SPECIFICATION TABLE 3.3.7.5-1 (ACCIDENT MONITORING INSTRUMENTATION) UNDER EMERGENCY CONDITIONS Other indicators pr ovide adequate feedback for ADS (r eactor pressure) and SRV operation, and Alternate Shutdown Cooling operation (reactor pressure/temperature) if they are required.

Additionally, MS-RV-1B is not controlled on either of the remote shutdown panels or an ADS valve.

As the failure of this acoustic monitor has only recently been identified, it was not possible for the Supply System to anticipate this event and submit this request in a

more timely manner.

Based on the

above, and the following no significant hazards consideration, the Supply System requests that the amendment as attached be granted until the next scheduled outage (no later than May 15, 1989),

or the next forced outage of sufficient duration to effect the necessary repairs.

Absent this amendment, the Supply System will be required to unnecessarily shut down by July 27, 1988.

The Supply System has evaluated this amendment per 10CFR50.59 and 50.92 and determined that it does not represent an unreviewed safety question or a

significant hazard because it does not:

1)

Involve a significant increase in the probability or consequences of an accident previously evaluated because FSAR Section 15.1.5 provides the analysis of an inadvertent opening of a

Main Steam Safety/Relief Valve.

This analysis assumes either a

malfunction of the valve or an operator-initiated opening.

The proposed change affects only the operability of the SRV position indication and does not affect automatic or manual actuation of the SRV.

The spring set and ADS function is not affected by the position indication.

MS-RV-1B is not an ADS valve or controlled from either of the remote shutdown panels (Appendix R).

In addition, sufficient alternate means are available to determine the position of an SRV.

2)

Create the possibility of a

new or different kind of accident from any accident previously evaluated because the proposal does not constitute a

physical change to the

plant, only recognition of a

single component failure.

The failure will not cause an incorrect assessment of valve position to occur as the same confirmatory devices relied upon are operable'nd sufficient to determine a not closed condition accurately.

3)

Involve a significant reduction in a margin of safety because of the special attention that will be provided to diagnosing MS-RV-1B valve position and the acceptability of the remaining methods of determining an SRV closed position.

Page Four NUCLEAR PLANT NO. 2 OPERATING LICENSE NPF-21, RE(}VEST FOR AMENDMENT TO TECHNICAL SPECIFICATION TABLE 3.3.7.5-1 (ACCIDENT MONITORING INSTRUMENTATION) UNDER EMERGENCY CONDITIONS As discussed

above, the Supply System considers that this change does not involve a significant hazards consideration, nor is there a potential for significant change in the types or significant increase in the amount of any effluents that may be released offsite, nor does it involve a significant increase in individual or cumulative occupational radiation exposure.

Accordingly, the.proposed change meets the eligibility criteria for categorical exclusion set forth in 10CFR51.22(c)(9) and therefore, per 10CFR51.22(b),

an environmental assessment of the change is not required.

This amendment request has been reviewed and approved by the WNP-2 Plant Operations Committee (POC) and the Supply System Corporate Nuclear Safety Review Board (CNSRB).

In accordance with 10CFR170.21, an application fee of one hundred fifty dollars

($150.00) accompanies this request.

In accordance with 10CFR50.91, the State of Washington has been provided a copy of this letter.

In summary, based on the assertion that no significant hazard is created by the subject relief and that remaining methods are available to satisfy the function of determining valve position, present operation does not represent an undue risk to the health and safety of the public.

Additionally, absent this amendment, the WNP-2 plant will be required to shut down.