'IttASHINGTON PUBLIC POPOVER SUPPLY SYSTKM-gggQO(g RQ(QQDO QQp p PLA.'IT PRO(:EDI RE IIA'ALAI.

Irxp.

PROCEOURE NUMBER eel ~ 3 VOLUMEe4AME APPR 0

DATE 6/30/83 1

ADMINISTRATIVEPROCEDURES SECTlON 1.3 CONDUCT OF OPERATIONS TITLE

+1.3.4 OPERATING DATA AND LOGS l.3.4.1 P~ur oee This procedure provides instructions to assure that plant operations are adequately recorded and the records are prepared,

reviewed, and main-tained in a meaningful manner.

The records are assembled on the graveyard shift daily and forwarded to the day shift manager for proper distribution and storage.

The minimum records included are:

A.

Shift Manager's Log Book B.

Control Room Log Book C.

Radwaste Log Book D.

Fuel Handling Log Book E.

Daily and Shift Operating Records F.

Periodic Surveillance Records G.

Operating Data Log Sheets H.

Computer Logs I.

Recorder Charts The Log Books will be duplicate logs.

Each book will be a bound book having two identical sheets per page number.

Each set of pages will be sequentially numbered.

The set of pages will have a carbonless copy.

The copy will be perforated so it can be removed for routing to Plant Management.

1.3.4.2 General Instructions for Record Partici ation A.

The logs will be the means by which operating information important to the following shifts and plant management is recorded.

It is, therefore, essential that log entries be legible, accurate and com-plete.

B.

A new page shall be started at the beginning of each graveyard shift.

8311310343 331111 PDDR ADOCII 05000397 p,

PDR PROCEOURE NUMBER REVISION NUMBER 1.3.4 PAGE NUMBER 1.3.4-1 of 10

~ )

V'F93 6"-.'.3JG8"I'f49QV<Q

~

)

~ U.

. All log entries shall be made in ink.,

0.

Erasures are not permitted.

If an error is made, it shall be voided by a single line drawn through the entry and initialed by the person voiding the entry.

E.

All entries in the Log Books shall be proceeded by a time and entered in chronological order.

Any late entries are to be made in the log by identifying the entry with L.E. in the left hand margin.

The time and date of when the entry should have been entered will be noted.

F.

G.

All log entries shall be entered in a timely manner.

It shall nor-mally be done immediately after the event occurred.

The Log Books will be identified by title, date started and

finished, and volume number on the outside of the front cover.

When completely filled out each Log Book shall be retained for reference in the Shift Manager's office, except for the Radwaste Log Book which shall be retained in the Radwaste Control Room.

When no longer needed for this purpose, the Log Books shall be routed to the Plant's Record Stora e File and rocessed per document guide in the g

p Plant Administrative Procedure 1.6.4.

1.3.4.3 S ecific Information for Record Pre aration H.

The perforated duplicate pages of the Log Books for the previous 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> time duration will be removed at the beginning of each grave-yard shift and routed =to the Operations Manager for his review, distribution, and storage.

A.

Shift Mana er's Lo The purpose of the Shift Manager's Log is to provide operational information important to the following shifts as well as plant man-agement personnel.

Although the extent and detail of the informa-tion logged will be determined and normally logged by the Shift

Manager, the following should be included as a minimm:

1.

Completion of a predetermined stamp at the start of each shift. If the predetermined stamp is not available, write in the following information:

a.

Shift and Oate b.

Shift Manager's Name ROCKOVRK NVMBKR RKVISION NVMBKR PAQK NVMBKR x.3.4 2

l.3.4-2 of 10

c.

Names of all individuals on shift d.

Designate Fire Srigade Member 2.

Any reduction in power and reason for same.

3.

Status and authorization permit number of radioactive releases to the environs.

4.

Timed entries for the following:

a.

Change of operating mode b.

Start of control rod withdrawal for reactor startup c.

Reactor criticality d.

Reactor trip and cause for same e.

Any technical specification limit exceeded or potential reportable occurrence including plant management notifica-tion.

5.

Initiation and completion of surveillance testing.

6.

Red arrow items a.

The purpose of this system is to provide a method of draw-ing attention to items where followup action is absolutely essential.

b.

Red arrow procedure-1)

When the Shift Manager encounters a situation where he deems followup action is mandatory, he shall note

'his by placing a red arrow in the margin to the left of the log entry.

2)

When a red arrow item is closed, the Shift Manager closing the item will make a "red arrow" entry stat-ing the reason or action for closing.

He shall write the word "closed" above the red arrow and log the page number and date of the originating red arrow entry below it.

The word "closed" shall then be written above the originating red arrow and log the page number and date of the closing entry written below it.

3)

Open red arrow items are identified by the lack of cross referenced log and page number and date written below the red arrow.

PRQCKQVRK NVMBKR RKVISIQNiVVMBKR iPAQK NVMBKR

'.3.4 2

i 1.3.4-3 of 10

v a

The open red arrow items shall be compiled and writ-ten in the Shift Manager's log each Monday on the graveyard shift.

'When compiling this list, the Shift Manager shall indicate the log and page number and date where each of the open red arrow items can be found.

5)

The Operations Manager shall assist in expediting red arrow items requiring engineering, maintenance, or management action.

7.

Any injury or sickness occurring on shift.

8.

The names of extra personnel required for plant operation.

9.

Any deviation from approved procedures as per PPM 1.2.4.

10.

Any significant maintenance activity occurring on the shift.

ll.

Other information or events the Shift Manager feels may have operational or historical value.

The Shift Manager shall enter the name of his relief and sign the log at the end of each shift.

t~ll The purpose of the control room log is to provide a complete and accurate account of plant operation to the following shifts as well as plant management personnel.

Entries shall be of sufficient detail that any previous plant condition can be reconstructed from them.

The Reactor Operator will normally be the individual making the entries into th Control Room Log Book.

The control room log shall be the OFFICIAL plant operating record.

The following should be entered as a mrnimum 1.

Completion of a predetermined stamp at the start of each shift. If the predetermined stamp is not available write in the following information:

a.

Shift and Date b.

Control Room Supervisor's Name c.

Name of all individuals on shift 2.

Plant startups and shutdowns.

PRACKDURK NUMBKR JRKVIBIQNiiUMBKR

~Paa K NUMBKR 2

1.3.4-4 of 10

, 3.

Significant power changes and the mechanism used to make the change.

4.

Status changes in equipment, components, or structures that affect plant operation.

5.

Initiation and completion of all surveillance tests.

6.

Initiation and completion of all special tests.

7.

Status and authorization permit number of radioactive releases to the environs.

8.

All electrical switching.

9.

Maintenance activities that affect operations.

10.

Other events,

alarms, and actions that control room operator feels may have operational or historical value.

The control room supervisor and the reactor operator shall enter the name of his relief and sign the log at the end of each shift.

~5t The purpose of the radwaste log is to provide the following shifts as well as plant management personnel an accurate record of all radioactive waste systems operation.

Entries shall be made by shift operating personnel.

The Radwaste Operator will normally be that individual making the entries into the Radwaste Log Book.

Entries shall include, but are limited to, the following:

1.

Completion of a predetermined stamp at the start of each shift. If the predetermined stamp is not available write in the following information:

a.

Shift and Date b.

Shift Support Supervisor's Name c.

Name of Radwaste Operator(s) 2.

All transfers of water from the radwaste system to the conden-sate storage or other plant systems.

3.

Status changes in equipment or components that affect plant or radwaste system operation.

ROCKDVRK NLlMBKR RKVISIONNVMBKR iPACiKNVMBKR 1.3. 4 2

1.3.4-5 of 10

I

~

I

, 4.

5.

Any unusual increase in floor drain or equipment drain systems inventory.

Status and authorization permit number or radioactive releases to the environs.

6.

Any other events or information the operator may feel to have operational significance.

7.

Any significant maintenance activity which occurred during the shift.

8.

9.

The Shift Support Supervisor will use this log to identify and relay to other shifts any information he determines to be important.

Other information the Rad Waste Operator feels may have opera-tional or historical value.

Upon making the last entry for his shift, the Shift Support Super-visor and assicped radwaste equipment operator shall enter the name of their respective relief and sign the log at the end of each shift.

~. ~ill dli The purpose of the fuel handling log 'is to provide following shifts and plant management personnel with information concerning all evolutions conducted on the refueling floor.

The fuel handling log shall only be maintained during periods of refueling floor acti-vity.

The Senior Reactor Operator in charge of fuel handling will normally be the individual making entries into the Fuel Handling Log Book.

At other times, it shall be stored in the Shift Manager' office.

1.

Completion of a predetermined stamp at the start of each shift. If the predetermined stamp is not available write in the following information:

a.

Shift and Oate b.

Fuel Handling Supervisor's Name c.

Names of all individuals on Refueling Crew 2.

Any discrepancies found during the inspection of new fuel.

3.

Any problem encountered with the movement of new fuel.

PROCKQURK NUMBKR RKVISIQNNUMBKR PAGK NVMBKR 1.3.4 2

1.3.4-6 of 10

l

~

~

~

d

4.

5.

The installation or removal of any reactor component.

Identification of the number of fuel elements,* control rods, and neutron sources handled during the shift.

The detailed accountability of these items will be controlled per instruc-tions in the Plant Procedures

Manual, Volume 9.

6.

Equipment failure and corrective action taken.

7.

Any situation involving unusual radiation or contamination levels.

8.

All evolutions involving the fuel cask and the shipping of fuel.

9.

Other information the refueling supervisor feels may have oper-ational or historical value.

The refueling supervisor shall enter the name of his relief and sign the log at the end of each shift.

E.

Dail and Shift 0 eratin Records The purpose of these records is to ensure that the daily and shift surveillance testing required by the technical specifications are accomplished and documented, and that the results are satisfactory or appropriate action taken.

The daily and shift surveillance records shall contain the following column headings:

1.

Technical specification reference 2.

Monitored parameter

3. 'nstrument number 4.

Parameter units of measurement 5.

Technical specification limit 6.

Normal value or range 7.

Actual value 8.

Comments When filled -out, the responsible operator shall initial the record below each "actual value" column.

~

Should any parameter fall outside the technical specification limit, the Shift Manager shall be immediately notified and that value circled in red with an explanation given in the Comments section.

The Shift Manager shall review the daily and shift operating records and sign them in the space provided.

RQCKQURK NUMBKR RKVISIQNNUMBKR iPACK NUMBKR 1.3.4 2'

.1 3'-7 of 10

~

~

1 n

k.

S I

ihe completed daily and shift operating records shall be forwarded to Operations Shift Manager for distribution and storage.

When no longer needed in the active storage file, it shall be routed to the Plant's Record Storage File and process per the Document Guide in the Plant's Administrative Procedure 1.6.4.

Periodic Surveillance Records See PPM 1.5.1, Technical Specification Surveillance Testing Program 0 eratin Data Lo sheets The purpose of operating data log sheets is to provide Operations personnel with periodic readings of important plant operating data.

This data is important to Operations because it may indicate trends'f developing equipment failures of improper operating practices.

This data is also of value to the performance personnel in" assessing long range trends of equipment operation and operating practices.

An operating data log sheet shall be maintained for the following plant areas:

1.

Control Room 2.

Reactor Building Turbine Building 4.

Radwaste Building 5.

Diesel Generator Building 6.

Service Building 7.

Makeup Water Pumphouse 8.

Circulating Water Pumphouse 9.

Standby Service Water Pumphouses The operating data logsheets shall contain the following column headings:

l.

2.

3.

4.

5.

6.

7.

Monitored parameter and/or instrument number Parameter unit of measurement Low limit Normal value High limit Actual value Special information The operating data logsheets shall be completed by Operations shift personnel.

Should any value fall outside the given high or low limits, the Shift Manager shall be notified and= the value shall be circled in red with an explanation given in the Comments section.

PRQCKQVRK N4M8KR RKVISIQNNUM8KR

~.3.4 2

PAGK N4M8KR 1.3.4-8 of 10

s 1

~

1

,, When filled out, the responsible operator shall initial the logsheet below the "actual value" column.

, H.

The completed operating data logsheet shall be forwarded to the day shift manager for review.

He shall investigate and determine the cause of any abnormal trends.

The purpose of computer logs is to provide Operation personnel, Plant management, and the Technical Department*with the necessary information to evaluate the performance of the reactor and balance of plant systems.

All parameters logged by the computer shall be checked periodically by shift personnel.

Selected plant operating parameters will be logged by the process

- computer and printed out on an hourly and monthly basis.

Other logs are pr'inted out when required or on demand.

During periods when the computer is out of service, selected plant parameters will be recorded by the operator.;

Each day the computer logs shall be routed by the Operations Manager to the Technical Department for evaluation.

After evaluation, the computer logs will be routed to the Plant's Record Storage File and processed per the Document Guide in the Plant's Administrative Procedure 1.6.4.

Recorder Charts The purpose of recorder charts is to provide Operations and Management personnel with a permanent record of'rends exhibited by specific plant parameters.

All operating charts shall be marked by the shift personnel responsible for the equipment at the beginning of each shift with the time, date, recorder

name, and other pertinent information that shall make the chart more useful.

Charts should be checked for timing to ensure chart indicated time corresponds with actual time.

When practicable, any unusual trends, or transients, should be identified on the appropriate recorder chart.

This identification should intersect at the recorder pen and consist of the event, date, and time to the 'nearest minute.

Chart paper will usually be replaced by the graveyard shift personnel when the end-of-chart indication is visible but can be done by any shift.

W~9&

ROCEOURK NUM8KR iRKVISIQNNUM8KR 1'3 4 I

2 PAQK iVUMBKR 1.3.4-9 of 10

, The date, time, recorder

name, and parameters shall be marked on each new chart when installed or removed from it's recorder.

In

addition, when installing a new chart the following chart box label shall be filled out with Date/Time that the chart is put on and the recorders name.

Date/Time Off Date/Time On I Recorder Name I

Upon removal of the chart, it shall be placed in its original box and the label filled out previously will be completed with time date off and placed on the outside of the box.

The chart will then be stored-in the Control Room on the "This Week" shelf.,

Charts from the week before will be on the "Last Week" shelf.

At the end of each week, Friday, the clerk will pick up all of "Last Week" charts and take them,to Document Control.

The clerk will then place "This Week" placard on the empty shelf and place the "Last Week" placard on the shelf with the previous weeks charts in it.

l.

20 3 ~

4.

5.

6.

7.

8.

9.

Shift Manager's Log Control Room Log Radwaste Log Fuel Handling Log Daily & Shift Operating Records Periodic Surveillance Records

-Operating Data Log Sheets Computer Logs Recorder Charts J.

The following records will be sent to Records Management to become a

part of the plant file.

The forms will be controlled per the Document Guide identified in PPM 1.6.4.

1.3.4.5 Attachments None W~QB PROCKOVRK NVMBKR JRKVISION NVMBKR iPAGK NVMBKR 1.3 4 I

2 1.3.4-10 of 10