I Su lement 83 THE FINAL SUPPLEMENT TO THE "ENGINEERING EVALUATION OF THE WNP-2 SACRIFICIAL SHIELD WALL" SUBMITTED TO NRC IN AUGUST 1980 1.

INTRODUCTION The purpose of this report is to provide information that closes all NRC related open items on the WNP-2 Sacrificial Shi'eld Wall (SSW),

including those previously identified (Ref. 1) and those occurring since August 1980.

Any additional activities associated with the SSW will be handled by normal WNP-2 procedures and documentation associated with those activities will be available for review at WNP-2 files.

The original report on the engineering evaluation of the WNP-2 Sacrificial Shield Wall identified a number of open items (Section I.D) which required additional testing or analysis to close out some aspects of the evaluation.

In addition, structural deficiencies were identified during the girth weld modification and during the testing of samples removed from ring beam 86.

The significance of these deficiencies with respect to the evaluation of the SSW has been addressed as an additional open item.

This supplement closes out the open items and commitments.

As will be discussed, the additional testing and analysis supports the conclusions of Ref. 1.

2.

OPEN ITEMS The following open items were previously identified:

2.1 Performance of qualification tests for electroslag welding procedures to confirm the mechanical properties of the weldments.

2.2 Removal of ASTM A588 material from the top ring (ring 86) of the Sacrificial Shield Wall to determine the NDT properties of this steel and to determine the margin between the NDT and the operating temperature.

2.3 Cold formi ng of ASTM A36 plate to the radius of the SSW for testing to confirm the assumed small shift in NDT produced by cold work.

2.4 Performance of a three-dimensional, finite element, dynamic analysis of the SSW to confirm the stress distribution used in the Ref.

1 evaluation.

aS0V040>02 eaO<as PDR ADOCK 05000397 PDR

'r

~,r

~<<~

<<<<<<r<<r 'r.<<'.rr rr << -'~r,.". '" o.', rk <<r,

'rr <<a~'~~W 'll~<~l'irt ACOp~~~r*'pMQ )pe

2.5 Submittal of final conclusions by the United Kingdom Welding Institute (consultant to the Supply System) considering addi-tional information obtained since their original report on the structural adequacy of the SSW.

Additionally, a number of deficiencies were detected during the performance of the girth weld and during the'esting of samples removed from ring beam 86.

These deficiencies have received special interest and add to the population of defects evaluated in Ref. 1.

Their implications for the structural evaluation of the SSW have been addressed in this report supplement.

3.

RESOLUTION OF OPEN ITEMS

3. 1 Confirmation of Mechanical Properties of Electroslag Welds A number of electroslag weld (ESW) qualification test plates were made to confirm the toughness and tensile properties of the ESW weld.

Direction for these tests was provided in Refs.

2 and 3.

The scope of testing, due to early results, was modified by Ref. 4.

The results of these tests are presented in Tables 1 and 2.

The NDT values for the ESW weld metal ranged from -10oF to

+ZooF.

The test data obtained supports the assumption, made in Ref. 1, that the maximum NDT value for the electroslag welds was

+20oF.

This provides a minimum margin of 80oF between the NDT value of 20oF and the operating temperature of the SSW.

The tensile properties (refer to Table 2) of the electroslag welds exceeded the minimum specified values for ASTM A36 in all cases.

Five of the A588 specimens did not meet the Code specified strength levels.

One coupon contained a defect; the other specimens'trength levels were marginally low.

In view of the low design stress levels in the SSW (see Section 3.4 of this supplement),

substantial design margin exists and the noted low strength values are therefore not a concern for the structural adequacy of the SSW.

3.2 Testing of ASTM A588 Material The web of ring beam 86 was made from 2-1/4 inch thick. ASTM A588 Grade 8 material.

Three heats were used, each supplied by the same steel fabricator.

l

/

The outside flange was made from 2-1/2 inch thick ASTM A588

material, one heat of Grade B and one of Grade H.

The Grade 8

material was supplied by the same steel fabricator as the web.

The inside flange was made from the same heat of 2-1/2 inch thick ASTM A588 Grade H material.

This heat was not used elsewhere.

The material used for the inside flange was inaccessible because of the presence of the reactor pressure vessel.

Therefore, samples were taken from the outside flange Grade H material and two of the four heats of Grade 8 (1 x 2-1/2" thick and 1 x 2-1/4" thick).

In addition to the base metal, two electroslag welds were sampled.

One was used to characterize the weld and the other to characterize the heat affected zone.

Directions for the extraction and testing of these samples were given in Refs.

5, 6, and 7.

Results of the tests are shown in Table 3.

The NDT values for the ASTM A588 base material and heat affected zone confirm the assumptions of Ref.

1 and provide a

minimum margin of 70oF between the maximum NDT and the operating temperature of the SSW.

The NDT value for the electroslag weld metal was higher.

This increase is attributed to the low manganese level of the par-ticular weld which was tested, possibly combined with pick up of precipitation hardening elements from the ASTM A588.

The manganese level in the other weld tested was significantly higher.

(Section 3.3 discusses the effect of cold forming on A588 NDT temperature.)

The NDT value of 60oF (see Table 3) provides a margin of at least 40oF between the temperature of the top ring of the SSW and the NDT.

The outside surface temperature of the SSW is predicted to be 100oF and the inside about 140oF at the top of the SSW (Ref. 8).

The maximum stress level developed in the top ring is in member 47 (see Section 3.4 of this supplement).

This maximum stress is 10.1 ksi or about 25K of the yield strength of the ESW weld zone.

At this stress level a margin of 40oF is more than adequate to provide crack arrest conditio'ns (see Ref. 1).

The three locations where the ASTM A588 material was removed for testing have been repaired.

The work was performed in accordance with PED 215-CS-A716.

g ~

I~

3.3 Effect of Cold Forming on the NDT of ASTM A36 and A588 Material Some plates used in the construction of the SSW were cold formed to the radius of the wall.

This cold forming could have changed the nil-ductility transition temperature of the mater ial.

ASTM A588 material removed from ring beam 86 (see Section 3.2) was in the cold formed condition.

Hence, the data discussed in Section 3.2 bounds the effect of cold forming on this material.

To determine the effect of cold forming on ASTM A36 tests were performed.

Details of the program are given in Ref. 9.

The results are presented in Table 4.

These results demonstrate that the level of cold work used in the SSW does not significantly affect the toughness of ASTM A36 steel.

Thus the conclusions in Ref.

1 with respect to the bounding NDT values for ASTM A36 are not affected.

Also, the data obtained on ASTM A588 from the top ring of the SSW can be applied to both as-received material and material rolled to the radius of the SSW.

3.4 Results of Three-dimensional, Finite Element Dynamic Analysis The conclusions of Ref.

1 were based upon stress levels calcu-lated using a simplified dynamic analysis (see III.B.2 of Ref.

1).

The Supply System committed to performing a three-dimensional, finite element, dynamic analysis to confirm the conclusions of the simplified analysis.

The three-dimensional analysis is reported in Ref. 10.

The results demonstrate that the controlling members, which are those adjacent to pipe penetrations and close to pipe whip restraints, have a maximum stress level less than 18 ksi.

Many of the controlling members have much lower maximum stress levels.

This is less than half the minimum Code specified static yield stress for ASTM A36. It should also be noted that in members subject to significant bending, these maximum stress levels only occur at localized areas of the members.

This analysis confirms the conclusions of Ref.

1 with respect to the stress levels in the SSW.

3.5 Deficiencies Detected during Girth Weld Installation and Testing of Samples from Ring Beam 86 3.5.1 Deficiencies Identified during Girth Weld Repair The following deficiencies were identified during preparation of the girth weld joint:

E I.

gl

'1

(i)

Linear indications in electroslag welds were discovered adjacent to the girth weld.

Details of this deficiency are given in Figures 1 and 2.

This deficiency was detected in two of the thirty-two electroslag welds in ring 83 which intersect the girth weld.

(ii)

Linear indications, slag inclusions and porosity were discovered in guide plate welds (see Figure 3).

(iii)

Lack of penetration existed at the weld joint between the bottom flange of ring beam 84 and the exterior web plate.

Details of this deficiency are shown in Figure 4.

For further discussion and clarification see Part 5.

(iv)

Linear indications in the girth weld excavation probably resulted from the repair of deficiency (iii) above.

3.5.2 Samples from Ring Beam 86 One of the samples taken from ring beam 86 contained a

field electroslag weld.

This weld joined two plates from the front flange plate.

Prior to machining drop weight test plates, the sample was examined by UT and sectioned for macroscopic exami-nation.

A subsurface defect was found which extended along the length of the sample.

The nature and extent of the defect is shown in Figure 5.

It consists of a lack of fusion defect on the sidewall of the weld which originally extended in from the surface of the weld, but was parti ally excavated and repaired.

In addition, two similar, but shallower defects were observed on the other side of the weld (Figure 5).

3.5.3 Significance of the Deficiencies These defici'encies are discussed in detail in Ref.

11.

It is concluded that the nature and severity of the deficiencies observed during the girth weld repair are bounded by the assumptions of Ref. I and that their discovery does not influence the conclusions of Ref.

1 with respect to the integrity of the SSW under design loading conditions.

0

,I I

3.6 Welding Institute Evaluation The United Kingdom Welding Institute was retained as a con-sultant for the original evaluation.

The additional data and information provided in this supplement have been transmitted to the Welding Institute for their review and comment.

They have concurred that the tests and analyses support the original SSW evaluation conclusions and that the recently identified deficiencies are bounded by previous assumptions.

(See Attachments 1 and 2.)

4.0 COMPLETED WORK AND CURRENT ACTIVITIES 4.1 Completion of Void Fill Program f

As identified in Concern No.

2 of Ref. 1, concrete voids had been located in the SSW.

There was a concern that other voids may exist in the SSW and thereby degrade the SSW shielding properties.

To resolve this concern, a program was developed to examine the wall to locate and repair such voids.

This program was outlined in Ref.

1 and has since been implemented.

Eighty-nine (89) voids were identified in the SSW and filled with BISCO NS-1 high density material.

The PED's issued to locate and fi11 the voids are listed in Table 5.

The adequacy of the NS-1 filler material was previously discussed with the NRC and formally addressed in Supplement No.

1 of the Engineering Evaluation of the WNP-? Sacrificial Shield Wall.

The original void fill program included plugging the drilled fill holes.

However, based on the SSW design the holes in the A36 plates have no structural impact and the related radiation streaming and/or contamination are not a concern; therefore, the decision was made to not plug the holes (see References 12 and 13).

4.2 External Weld Defect Repair Work has been completed in bringing 236 welds into compliance with AWS Dl.l as required by the NRC (see Ref. 14).

These welds were identified in previous correspondence as being accessible for repair.

Repair of these welds was initiated by PED 215-W-A368 and work was performed in accordance with Bechtel Weld Procedure Pl-A-LH (Structural).

All work has been inspected to AWS D1.1 and approved by gC.

~ -

~

r'*~

~ '

"'PQM<<<<'<<>> ~

Wm

'.P<<<<~ "4'<<<<<<~<<<<

~ 'I 4k<~

The total number of welds originally identified for repair was 239; however, three were deleted for the following reasons:

o Weld No.

211 of weld map W131 was declared inaccessible for repair in NCR 215-08100.

Two welds were recorded twice.

Welds 147 and 152 of weld map WF 23 were inadvertently recorded as welds 155 and 158 of weld map W23.

Welds 155 and 158 are inac-cessible as skin plate No.

39V covered these welds.

Table III C.7 (attached) is a corrected version of the same table in the original report reflecting the pre-ceding changes.

This revised table should be used in place of the table in the original report.

4.3 Completion of Defect Removal at Azimuth 187o-30'nd 541'levation Supplement No.

2 of the Engineering Evaluation of the WNP-2 Sacrificial Shield Wall, Part II.B identified areas where linear indications appeared during preparation of the SSW girth weld joint.

Major work was required to complete the defect removal at 187o-30'.

This repair required the removal of a ring 4 skin plate and concrete above the area.

This work was initiated by PED 215-CS-A347.

Repair was completed in accordance with PED 215-W-A652 and PED 215-W-A750.

After completion of the repair, the skin plate was replaced and NS-1 material was placed in the affected compartment in place of the concrete.

This work was completed under the direction of PED 215-M-B049 and PED 215-M-8125.

All related work has been completed with inspection ar~d acceptance by QC.

During this repair work, additional concerns

~rose.

While welding the skin plate back on at azimuth 187 -30't 541'levation, the controlling thermocouple for preheat sensing the temperature on the wall became dislodged.

A temperature excur-sion between 450oF and 475oF occurred in this area of repair.

This exceeded the specified preheat of 350oF and was documented on NCR 250-0945.

There was concern that these temperatures could have adversely affected the welds within the area of the 165o to 210o AZ.

To disposition the NCR; direction was given by PED 215-W-C287 to magnetic particle inspect all welds from 541'5" elevation to 555'levation, 165o AZ to 210oAZ.

There were no cracks or reportable indications found.

To prevent repeated problems with temperature excursions, temperature recorder charts were added to provide additional

~ g

~ ~

4.4 temperature monitoring capabilities.

A full-time craftsman was assigned to monitor preheat

controls, and the welding engineer generated a log to identify when and where preheat was being accomplished.

NCR 250-09544 reported NS-1 had extruded from the wall in the area where temperatures exceeded the 350oF preheat.

Concern for a decrease of shielding in this area of the wall existed.

To resolve this concern the area has been identified and added to the list of areas to be monitored during the startup radia-tion scan program.

Linear Indication on the Sacr ificial Shield Wall at 544'6" A crack was discovered on the Sacrificial Shield Wall at 544'6" elevation and 80o azimuth.

The crack was adjacent to weld No.

262 on weld map W61, a diaphragm plate to skin plate weld.

This was reported on NCR 215-09021.

There was concern whether the crack was the result of the girth weld at elevation 541'.

To ensure such a defect did not exist in other suspect locations, seventeen other locations on the wall of similar configuration were examined.

No other cracks or linear indications were found.

During excavation it was deter-mined that the crack originated in the root of the weld.

The possibility exists that. the girth weld either caused the crack to propagate or open.

See Reference 15 for details.

The repair work was performed in accordance with AWS Dl.1 per PED 215-W-B030 and Bechtel Meld Procedure P1-A-LH.

All work was inspected and approved by g.C.

It should be noted that this specific defect, and others which could be reasonably postulated, are enveloped by the fracture assessment in Section III.D of the original evaluation report.

5.0 Discussion of the 1/4" Incomplete Penetration Identified in Supplement No.

2 of the Engineering Evaluation of the MNP-2 Sacrificial Shield Wall.

5.1 The Engineering Evaluation of the WNP-2 Sacrificial Shield Wall Supplement No. 2, Part II.C identified three locations where incomplete penetration

( I.P.) was discovered in the partial penetration flange-to-web plate weld on ring 4.

(See Figure 4

of this supplement).

The incomplete penetration identified was 1/4" deep; however, the original report addressed 5/32" as the worst I.P. case in Table III D.5.

The purpose of the following discussion is to address the 1/4" I.P. relative to the previous SSW structural assessment.

~

C

As discussed in the initial evaluation report (Ref.

1) incomplete penetration promotes failure by plastic collapse rather than by brittle fracture.

Table III.D.2 of the initial report lists the critical flaw depth to thickness ratios for plastic collapse to occur.

This table lists a/t ratios for static loading and dynamic loading taking into account bending and tension.

These ratios were developed by using the actual design stresses of the wall.

Burns and Roe Technical Memor andum 1218 reported the results of the three-dimensional finite element dynamic analy-sis, confirming that the stresses in the SSW for the most criti-cal members and load combinations are less than half of the yield stress of the material.

The stresses that were reported in this analysis were less than those used in developing Table III.D.2.

These lower stresses allow the a/t ratio to be larger than reported which in turn would allow a larger flaw to exist.

In comparing the a/t ratio of 0.33 for the 1/4" I.P. in 3/4" thick material to Table III.D.2, there are no a/t ratios in either the static loading or the dynamic loading columns for any of the materials equal to 0.33.

Therefore, plastic collapse wi 11 not occur.

An a/t ratio greater than 0.5 would have to occur before plastic collapse could occur.

In addition, the potential for plastic collapse is reduced by the design of the SSW.

For plastic collapse to occur, large strains and displacements are required.

The SSW is a redundant structure in that loads are transmitted through many members in parallel'.'he displacement which can be applied to a weld joint is limited by parallel joints.

The design and the evaluation for plastic collapse leads to the conclusion that the 1/4" I.P.

will not cause plastic collapse and is enveloped by the original assessment of the wall.

Table III.D.5, attached, is revised, reflecting the 1/4" incom-plete penetration, and a corrected typographical error for undercut.

6.0

SUMMARY

The open items identified in Ref.

1 have been closed out by testing or additional analysis.

The implications of additional deficiencies identified during the installation of the girth weld, during testing of samples from ring beam P6, and the crack at 544'6" have been evaluated.

It has been determined that the conclusions of Ref.

1 have been reinforced and remain valid with respect to the as-built structural adequacy of the SSW.

I

REFERENCES "Engineering Evaluation of the WNP-2 Sacrificial Shield Wall" IOM from D. Burns/C.

M. King to D. C. Timmins, "gualification of Leckenby Electroslag Welding Procedures",

F-80-1491, dated April 8, 1980 IOM from D. Burns to D. C. Timmins, "NDT Testing, SSW Evaluation",

EMN-DB-80-11, dated April 25, 1980 Letter from G. I. Wells (SS) to P. J. Garcia (WBG), "Sacrificial Shield Wall (SSW)

Boecon Welding Procedure Testing",

WNP2WBG-215-F-81-034, dated January 7,

1981 PED215-W-4926, "Sacrificial Wall Test Samples",

dated July 15, 1981 Site Support Work Order FJB-1171 (BECWBG-215-81-0432),

dated July 31, 1981 IOM from D. Burns to D. C. Timmins, "Additional Direction to Anamet",

EM-DB-81-74, dated September 15, 1981 Burns and Roe Memorandum, V. F.

Rubano to R.

E. Snaith, "Minimum Temperature of Sacrificial Shield Wall", dated March 24, 1980 IOM from D. Burns to D. C. Timmins, "Effect of Cold Work on the NDT Temperature of ASTM A36 Steel Plate Used in the SSW of WNP-2",

EMN-DB-80-41, dated October 16, 1980 Burns and Roe Technical Memorandum

1218, "Stress Evaluation of the WNP-2 Sacrificial Shield Wall - Using 3-Dimensional Model for Dynamic Analysis", dated January 8,

1981 IOM from D. Burns to D. C. Timmins, "Evaluation of Deficiencies Found During the Girth Weld Repair and During Testing of Material from Ring Beam 86,

SSW, WNP-2", EM-DB-81-76, dated September 18, 1981 IOM from J. 0. Parry to D. E. Larson, "Visual Inspection of WNP-2 Sacrificial Shield Wall", dated February 23, 1982 Letter from B. A. Holmberg (SS) to A. Cygelman (BER) WPBR-F-82-029 dated February 18, 1982 Letter from the NRC to R. L. Ferguson, "Review of Defects in the WNP-2 Sacrificial Shield Wall", dated February 25, 1981 IOM from P. J. Inserra to W. G. Keltner, "Sacrificial Shield Wall Crack at 544'6" - 80oAZ: Synopsis of Events",

F-82-1148 (SS2-PE-82-68)

TABLE 1 RESULTS OF NDT TESTING ON ELECTROSLAG WELD TEST PLATES A5 A7 AB B5 B6 B7 El E2 E3 F2 2 II 2ll 1-1/2" 3ll 3 II 3 II 2-1/2" 2-1/2" 2-1/2" 2-1/2" A36 - A36 A36 - A36

. A36 - A36 A36 - A36 A36 - A36 A36 - A36 A588 GRB-A588 GRH A588 GRB-A588,GRH A588 GRH-A588 GRH A36 - A588 Plate No.

Thickness Base Metals Weld Metals Cl a'C CU Weld

-10oF t

~20op(2)

+10oF

- -10oF

+20oF(3)

+20oF

+10oF OoF

+10oF (4)

NDT Values Base Metal

-10oF (1)

HAZ*

+20oF

-20oF

-40oF

+10oF

+30oF (A36)

+10 F (A36)

-20oF (A588)

+10 F (A588)

(1)

Only one no break obtained (2)

One no break obtained at +10; one break at +20oF (3)

One no break obtained at +10 and +20oF; one break at +20oF (4)

One no break at -10oF;~one no break at OoF; one break at +10

. Heat Affected 7one (HA7.)

I

~n,

'F

TABLE 2 RESULTS OF TENSILE TESTS ON ELECTROSLAG TEST PLATES

'-Transverse Tension Tests All Weld Metal Tension Tests Plate No.

Yield Strength Ultimate Strength Elongation si Yield Strength Ultimate Strength Elongation

~si X RA**

85 45290 49940 49570 46980 68000 67120 66110 66090 45 45.5 43.5 46.0 47030 69310 27 64.8 B7 44240 42780 49080 46990 62770 62030 64420 64370 40 39.5 40 44 46270 64430 26 59.4 E2 56640

  • 44150 56160 59360 74890 44150 73010 74050 33 4

37.5

36. 5 52740 75370 26 54.7 E3 47880 51850 51740 52020 70760 71290 69240

~ 69680 33 38 36.5 39.5 49000 7.1390 27.

64.2 F2 50280 55210 53770 53390 69940 70610 70070

'0220 39 39.5 41.5 40.5 52250 73500 27.5 61.3.

Flaw in weld

~ Reduction of Area (RA)

TABLE 3 RESULTS OF TESTING OF MATERIAL FROM RING 46 OF SACRIFICIAL SHIELD WALL Sam le T-2-A 0-7-A 0-8-A 0-8/7-G Heat No./

Meld No.

801S 29340 801S26800 52690 WF109-6 Specification and Grade A588 Grade B

A588 Grade B

A588 Grade H

ESW Weld NDT Tem~.

+30oF 20oF

+20oF

+60oF Yield Strength Transverse 41500 psi 40,000psi Ultimate Strength Transverse 61700 psi 58300 psi Analysis

%C

'XMn 0.14 1.07 0.15 1.04 0.11 0.77 0.11

. 0.

0-7/8-J-HZ WF109-24 ESW HAZ in Heat No. 52690

+30oF (Note 1) 0.12 0.83 (Note 2)

Note (1)

Break obtained at +30oF after'no break at +20oF and +30oF (2)

Obtained on weld metal

K k

'I

TABLE 4 EFFECT OF COLD FORMING ON THE NDT OF ASTH A36 Heat No.

155602 15576&

205957 Thickness 1-1/2" 1-1/2" 1-1/2."

Inside Diameter Radius 86" 86" 79.5" As Received

+10oF

-10oF

-10oF NDT Tem erature Cold Formed Note 1

OoF

-10o OoF'ote (1)

The plates were cold rolled to the radii noted above.

The minimum radius for the SSW is 156".

The radii used for cold forming'were calculated to bound the strain level in 3" thick plates formed to a radius of 156".

~ P

\\

S

~i J'

Table 5

ADDITIONAL PEDs - CONCRETE VOID PROGRAM A347 - Remove plate 014 B049 - Partial Fill Compt 14 (B125)

A168 - Drill holes A370 - Angle change A165 - Void Fill 3452 -

NDE Method A155 - Hake tapered plugs A505 -

NDE -

SAC Wall A548 - Word change to A505 A619 - Word change to A505 A628 - 3/4" hole - plate 187 A637 - 5/8" hole - 187 A649 - Drill holes A655 - Drill holes A660 - Drill holes A714 - Drill holes A724 - Drill holes A725 - Drill holes A852 - Drill holes A877 - Drill holes A901 - Drill holes A919 - Drill holes A926 - Void Fill A968 - Drill holes A977 - Drill holes A979 - Drill holes A980 - Drill holes A981 -

Dr ill holes A990 - Fill Voids B024 - Fill Voids 8015 - Drill holes B016 - Drill holes B017 - Drill holes B018 - Drill holes B039 - Drill holes B040 B042 B047 B053 A982 B069 B070 8079 8071 B106 B116 B090 B136 B091 B144 B092 B093 8137 B158 B159 8177 B200 B187 B160 B209 8214 8215 B222 8224 B223 B235 B253 B080 8165

- Drill NS-1

- Word change

- Refills

- Drill hole

- Triple Amt.

- Fill Voids

- Drill holes

- Refills lugs changes sure

- Documentation

- Drill hole clo

- Fill Voids

- Delete sheets in PED's

- Drill holes

- Fill Voids

- Drill holes

- Drill holes

- Drill holes

- Fill Voids

- Drill holes

- Drill holes

- Drill holes

- Drill holes

- Drill holes

- Drill holes

- Fill Voids

- Allow Fills

- Clarification for "B"

- Drill holes

- Drill holes

- Drill holes Fill Voids

- Drill holes

- Fill Voids

- Locate holes

TABLE III.C.7 BURNS AND ROE VISUAL INSPECTION DATA Total Welds Evaluated Total Acceptable Welds Total Inaccessible Welds No. Exceptions by Weld No. Fillet Welds with Exceptions No. Groove Welds with Exceptions 1698 1408 54 236 193 43 Defect Breakdown Defect T

e No. Recorded (c)

Cracks Undercut Porosity Crater Fill, Cavity Underfill Over lap Convex Fillet Excess Reinforcement LOF (a)

Ar c Strikes,

Slag, Temporary Attachments Undersize Fillet ( ), Unequal Leg, Weld Profile Linear indications, file, knife marks None 32 14 74 t*~

4 38 6

17 101 3

(a)

These incomplete fusion defects are less than 1 inch in length and may in actuality be acute fillet re-entrant angles or indications other than lack of fusion between the base metal and weld.

(b)

Percentage of fillet weld length affected varies.

(c)

Multiple defects exist in certain welds.

~

~

1

Table III.D.5

SUMMARY

OF WORST CASE DEFECTS IN WELDMENTS Rece i an Defect T

e Largest Reported Length x Width x Depth (a)

Inches Potential Failure Mode Parent Plate Arc Strike Lamellar Tears Heat Affected H-cracking Zone Liquation Cracks 3/8 x 3/8 x 1/32 None None None Fusion Boundary Weld Metal Lack of Fusion Crack Undercut Undersized Fillet Overlap Underfi 1 1 Excess Reinforcement Porosity Crater Fill 8 x'0 x 0 (b) 39 x 0 x 0 (ESW)(e) 13 x 0 x 1/8 (c)

B.x 0 x 1/8 24 x 0 x 0 (ESW) 26 x 0 x 1/4 (d) 3 x 0 x 1/8 4 x 0 x 1/8 24 x 0 x 0 (ESW) 72 x 0 x 1/4 8 x 0 (boundary area) 19 x 1 (boundary area, ESW) 1 x 1/2 x 3/8 P,

F P,

F P,

(F)

(1)

(P)

(P)

Incomplete Penetration Varies x 0 x 1/4 (f)

P, F

Slag Inclusions 1-1/2 x 0 x 0 F - Fracture, P

= Plastic collapse,

.(

) - signified lower probability (a)

Depth in the thru-thickness direction.

(b) 0 - signifies dimension unknown.

(c)

One 2-1/2 inch long crack extended through the 1-3/4 inch thick electro-slag weld.

No other such occurrences have.been identified in the documentation.

(d)

Worst case based upon percentage reduction 'in are from original weld size (e)

Available information from industry sources indicates a maximum depth for this type of corner lack of fusion of 1/2".

(f)

Identified at various locations analysis takes into account full length.

~ F

~

~

D AZ. I'B5 -150 R/NC 4 ~)

+ APPROX INDICPTIQN 1" I'V, R IHG "3 3 THICK

'A4 ELEC'TROSLAG.%'E,LD (2 GAP)

OUT SOAP',g~

Dc,F=C~

~)g g1G/

bQ.E.P N'T&.

RING 4 IIrg INBOARD GIRT W WE.LD E,XCAVATION g/

1/z

~RIhl6 +3

I

~

~

~

e REPAIR F XTFHDED ABOUT +" DOWN WALL 1

RiNG~5:..

{

IWD)CP'TlONS REPORTED B A,PP.RT E,l ECl'RQSl AG 'PFLP I wRT CL,aVWT t aH L APPROX 'S/+

1NDlCATlOgS

<lNl-A(,

<W<aQ4;Qo<Q LN

/WE 5 (T

QO-i@5 gZ..

4

'il

R1vt

~1@TH WELD EXCAVA'T10g L

1/g mg

'9 TM+

R,AN@ hW h

~3 WQLD GO( DE ESW 1 CRP C'1:T ll'1

.&HQWW P'gg CI rER1TY F LE.VWTION Gu1OE +.

I B

-rop a I

Es yv HE.C,71QH M-P-GUI DE.

Fx'TENT OF EX'PTION R3HG +4 glhlG+ 3 I

133 I

i/<g'OI fR.(RING+'5)

MEC: T I CON P-E gu<QC pent%

W~~

47 I'L7 3n (Sii3iLIiC Iit'7 IiiIb 3 4-3i I

~ I 0

\\,

5 1

A

l I

I

~ I RtNG I

I I

CUT EoAP.P FAcE, ~

~ P.IN6¹4

~I pi<zgs<og:vp-p ice g -Pp RiNG< 5 CI 0

e 35

'P S

~U1LT C:C)N COl7ION A'T P Z.. &CO-l05 0- j>

~AC lB,o l BS pg. +.. lgoc ep V<gCT(oqlog (r

gx. 9o -lo5 0-LS (hip LCD

155,

l~

~

~

g ~

THE M/ELDINR INSTITLITE PLEASE REPLY TO RESEARCH LABORATORY ABINGTON HALL ABINGTON CAMBRIDGE CB1 6AL Telephone CAMBRIDGE 0223 891162 Telegrams WELDASERCH CAMBRIDGE Telex 81183 LONDON OFFICE 54 PRINCES GATE EXHIBITIONROAD LONDON SW7 2PG Telephone 01.584 8556 Telegrams WELDINST LONDON S.W.7 AAW/VAN/119 1

10 February 1982 Mr R A Moen, Washington Public Power Supply System PO Box 968 3000 George Washington Way Richland Wa.

99352 USA.

Dear Mr Moen,

Draft Supplement No 3 WNP-2 SSW Evaluation LD 22757 Further to my telex of 1 February 1982, I should like to clarify my comments on your draft supplement.

My main concern was with the electroslag welds used to attach the pipe whip restraints.

It is apparent from the high incidence of rejects reported in Section III.C.8 of the Engineering Evaluation that either the weld procedure was incorrect or it was not being followed.

The defect described as "shrink" is most probably what we wo'uld call a solidification crack, aligned vertically on the weld'entre-line.

The most likely cause is welding too

rapidly, so that a very deep weld pool is formed.

The high wire feed speed would require a high voltage or current to raise the heat input sufficiently, as you reported.

These solidification cracks can be fairly,sharp, and are most probably surrounded by regions of poor toughness, owing to the segregation of non-metallic inclusions to the weld centre-line during cooling.

If this conjecture is correct, then the result is a large, potentially crack-like defect with its tip in a region of low toughness.

The values taken for the NDT temperatures of electro-slag welds in A36 and A588 steels may not represent upper bounds for these particular welds, so that there is a potential risk of fast fracture.

Possible courses of action would be to repair all the defective electroslag welds in the pipe whip restraints, or to measure the NDT temperatures at the weld centre-line on some of these particular welds.

/continued

her R A bIoen Washin ton Public Power Supply System 10 February 1982 There were a number of other more minor points which I feel should be made clear, but which do not reduce the level of confidence in the structural integrity of the SSW.

1.

In Section III.C.2 of the Engineering Evaluation, it is stated that the entrapment of slag at the outside corners of electroslag welds results in defects which are not equivalent to planar lack of fusion.

In our experience, these defects usually arise from inadequate heat input and/or poor weld The procedure, which in turn cause lack of fusion at the co ne r

rs.

e slag which becomes trapped in the defect is a symptom of its presence rather than a cause of the defect per se.

The defect is essentially lack of fusion and can be planar and crack-like I with a sharp tip.

However, the presence of these defects does not reduce the level of safety of the

SSW, because the NDT temperatures of these 'electroslag welds should be low enough to ensure crack'rrest.

2.

The tests, on the electroslag welds are indicative of NDT temperatures below +20oF, but do not prove the case.

This is because:-

i)

The dilution in electroslag welds is high, typically 40-50%%%d.

Therefore the properties of the weld metal will vary significantly with base metal composition.

Since the relevant base metal specifications are rather loose (particularly for A36 steel),

there is no guarantee that the same weld procedure will produce'the same weld properties'n

'w'elds fabricated from different heats of base metal..

I am assuming, from the information you,.sent me,

~ -that 'ba'se materials for the test plates were procured at random from a steel stockist, and not cut from the SSW.

ii)

The cooling rates in the test plates were probably lower than in the

SSW, because in the fabrication of the former relatively narrow plates were used (5-12in. in width).

To simulate the cooling rates more closely, we would recommend that either the same width of plate be used as in the structure, or where the structure contains very large plates, the test plate width be at least 36in. either side of the weld.

However, your tests do provide support for the estimate of the upper bound NDT temperature of +20 F used in our report LD 22526.

Using the lower stresses which you have calculated the crack arrest temperature is less than the minimum service temperature by a substantial margin.

3.

The draft version of LD 22526 assumed a dynamic elevation of the flow stress of 65%, but examination of further work suggested

~ I I

Mr R A Moen Washin ton Public Power Suppl System 10 February 1982 that this could be an overestimate.

Therefore a lower bound to the dynamic elevation was taken to be 30%%d in the final version, of LD 22526.

However, in Table III.D.2 you have used the earlier assumption of 65%%d.

The difference is relatively insignificant, because with a maximum dynamic stress of 18 ksi, this 30%%d elevation still gives allowable defect sizes which exceed those likely to be present in the SSW.

4.

A very minor point is that in your Draft Supplement No 3, Sections 3.5.1 and 3'.2, you refer to figures 1 to 5, which were not attached.

I assume that these are the same figures as occur in your reference ll and the attachment thereto.

In conclusion, I am happy that, with the exception of the electroslag welds in the pipe whip restraints, your subsequent work has increased the level of confidence in the structural integrity of the SSW above that which obtained at the time of issue of our report LD 22526.

I Yours sincerely, A A 'INlloughby

0

/0 I'D.&W~<

THIS LETTER SATI ES COMMITMENTNO.

I ~

IW INTERNAL"DISTRIBUTION PW Harness/lb April 2, 1982

'C Timmins/lb G02-82-361 PJ I/1 b I

fkAMfl b

.DW Porter Dr. A. A.

Wi l Ioughby 4C. Control The Welding Institute Abington, Cambridge CBI-6AL

'- -" P-2 Files United Kingdom

Subject:

SUPPLY SYSTEM NUCLEAR PROJECT NO.

2 WNP-g SSW EVALUATION-LD22757, SUP-PLEMENT 3 THIS LETTER (DOES( (DOES NOT) ESTABLISH A NEW COMMITMFNT.

WPPSS CORRESPONDENCE NO.

In reference to your letter AAW/VAN/119 of February 10, 1982, you have expressed some concerns over data and conclusions in our Draft Supple-ment 3, WNP-2 SSW Evaluation-LD 22757.

This letter hopes to clarify any outstanding concerns.

1.

Concerns over electroslag welds used to attach pipe-whip restraints need not be addressed for the. following reasons:

'a.

Pipe-whip'estraints fabrica4ed employing the ESW process have been completely refabricated using

SAW, FCAW, and/or SMAW.

This refabrication was made necessary primarily due to the low mechanical (impact) properties expected in these welds.

It

~'hould be clarified that ESW was employed only in joining the pipe-.whip restraint web plates to their associated base plates.

'These base plates are, in turn, bolted to pipe-whip supports.

~ b.

Pipe-whip supports have been attached to the SSW employing FCAW and SMAW processes and were not welded with the ESW process.

c.

Some electroslag welds were employed in attaching structural steel to the SSW.

They were radiographed and repaired as necessary.

The SSW fabricator (Leckenby Co.)

had established a repair program to address this type of defect.

Subsequent UT exami-nation has verified that such defects were being repaired by Leckenby.

.b.

Illustrations provided with original fabrication defect des-criptions indicate the re-entrant angles at the interface of the lack-of-fusion regions and sound fusion regions were not sharp and thus not crack-like.

2.

The concern over entrapment of slag at the outside corners of the electroslag welds resulting in planar and crack-like lack of fusion is not sign'ificant due to the following reasons:

AUTHQR:

PJ Inserra SECTION FOR APPROVA APPROVED DATE r ess.

DC Timmins FQR slGNATURE DF:

RA Moen

Dr. A. A. Wi lloughby Apri 1 2, 1982 Page 2

G02-82-361 3.

Item 3 of your letter discusses the different dynamic elevations of flow stress used to formulate the critical'law depth to thickness ratio.

As you stated, the final version of LD 22526 used

'a dynamic elevation of 30 percent (Table 5), as opposed to 65 percent used in Table III.D.2 of the supplement.

It is understood that 30.percent dynamic elevation is more conservative than 65 percent.

However,

'able III.D.2 has used a design stress of roughly 0.5 yield stress which is the actual case for the designed structure, as opposed to the full yield stress of a given material as employed in Table 5

for calculation of the a/t ratio.'e concur that the differences between the a/t ratios of Table

.5 and Table III.D.2 are insignificant when the actual design stress

,is used with a dynamic elevation of 30 percent.

In conclusion, we appreciate your clarification of comments on Draft Supplement No. 3.

I hope this letter puts to rest any remaining concerns over the draft supplement.

R. A. Moen - 430 Lead, Welding 5 Materials PJI/taj