ML17276B600

From kanterella
Jump to navigation Jump to search
Forwards Request for Addl Info on Fuel Rod Corrosion Measures,Per Core Performance Branch Review of Fsar. Notification Requested within 7 Days If Responses Cannot Be Submitted by 820924
ML17276B600
Person / Time
Site: Columbia Energy Northwest icon.png
Issue date: 08/09/1982
From: Schwencer A
Office of Nuclear Reactor Regulation
To: Ferguson R
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
References
NUDOCS 8208250472
Download: ML17276B600 (4)


Text

AUG 9

3982 Mr. R. L. Ferguson Hanaging Director Washington Public Power Supply System P. 0.

Box 968 3000 George Washington Way Richland, Washington 99352 DISTRIBUTION:

LB¹2 File Local PDR RAuluck NSIC EHylton PRC ACRS (16)

I81E

Paton, OELD R.

Meyer Region V

Dear IIr. Ferguson'

Subject:

Request for IAddiitional Information on Fuel Rod Corrosion Measures As a result of our review of your application for operating license we find that we need additional information regarding thetWNP,'-2 FSAR.

The specific information required is as a result of the Core Performance Branch's review and is listed in the Enclosure.

To maintain our licensing review schedule for the WNP,'-2 FSAR, we will need responses to the enclosed request by September 24, 1982. If you canno't meet this date, please inform us within seven days after receipt of this letter of the date you plan to submit your responses so that we may review our sch'edule for any necessary changes.il Please contact Rag Auluck, Licensing Prjj'ect Manager, if your desire any dis 'ussion or clarification of the (e'nclosed /request.

Sincerely,

Enclosure:

As stated A. Schw'encer, Chief Licensing Branch No.

2 Division of Licensing 8208250472 820809 PDR ADOCV 05000W7 A

PDR OFFICEI SURNAMEIN DATE$

DL:L ¹2 M

~ IO ~

c k : pt

..8/.'KJ8.2........

L:L C

ASch pncer 8

(82 NRC FORM 318 (10-80) NRCM 0240 OFFICIAL RECORD COPY USGPO.'981~

960

WNP-'2 Mr. R. L. Ferguson Managing Director Washington Public Power Supply System P. 0.

Box 968 3000 George Mashington May

Richland, Washington 99352 CC:

Nicholas Reynolds, Esquire Debevoise 8 Liberman 1200 Seventeenth

Street, N.

W.

Washington, D. C.

20036 Mr. G.E.

Doupe, Esquire Mashington Public Power Supply System-P.O.

Box 968 3000 George Washington May

Richland, Washington 99352 Nicholas Lewis, Chairman Energy Facility Site Evaluation Council=.

Mail Stop PY-ll Olympia, Mashington 98504 Roger Nelson, Licensing Manager Washington Public Power Supply System P.O.

Box 968 Richland, gashington 99352 Mr. W.G. Conn, Sr.

N/N Group Supervisor Burns and Roe, Incorporated 601 Williams Boulevard Richl and, Washington 99352 Nr. Richard Feil U.S.

NRC Resident Inspector WPPSS-2 NPS P.O.

Box 69 Richl and, Washington 99352 Dr. G.D. Bouchey Deputy Director, Safety 8 Security Washington Public Power Supply System P.O.

Box 968, MD 650

Richland, Mashington 99352

ENCLOSURE Request for Information on Fuel Rod Corrosion Measures Section 4.2.3.1 (4) of NUREG-0892 (the WNP-2 SER) addresses the issue of waterside corrosion.

Although we do not understand the exact damage mechanism, we do understand that General Electric.

has a task force studying this problem and that you will meet with General Electric this summer to determine suitable preventive actions.

After that meeting, please inform us of the measures that you will adopt to avoid fuel rod waterside corrosion damage in WNP-2.

1 4

~

4 P

I