RBG-47789, Request to Use a Later Edition and Addenda of the ASME Boiler and Pressure Vessel Code, Section XI, for Inservice Inspection (Lsi) Activities at River Bend Station, in Accordance with 10CFR50.55a(g)(4)(iv)

From kanterella
(Redirected from ML17275B088)
Jump to navigation Jump to search

Request to Use a Later Edition and Addenda of the ASME Boiler and Pressure Vessel Code,Section XI, for Inservice Inspection (Lsi) Activities at River Bend Station, in Accordance with 10CFR50.55a(g)(4)(iv)
ML17275B088
Person / Time
Site: River Bend Entergy icon.png
Issue date: 09/27/2017
From: Schenk T
Entergy Operations
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
RBG-47789
Download: ML17275B088 (5)


Text

~

Entergy" RBG-47789 September 27,2017 Attn: Document Control Desk U.S. Nuclear Regulatory Commission 11555 Rockville Pike Rockville, MD 20852-2738 River Bend Station, Unit 1 Docket No. 50-458 License No. NPF-47 TImothy Schenk

SUBJECT:

Request to use a later Edition and Addenda of the ASME Boiler and Pressure Vessel Code,Section XI, for Inservice Inspection (lSI) Activities at River Bend Station, in Accordance with 10CFR50.55a(g)(4)(iv)

Dear Sir or Madam:

Pursuant to 10 Code of Federal Regulations (CFR) 50.55a(g)(4)(iv), and in accordance with the guidance of Regulatory Issue Summary (RIS) 2004-12, Entergy hereby requests to use a later Edition and Addenda of the ASME Boiler and Pressure Vessel Code,Section XI, for the River Bend Station (RBS) Inservice Inspection (lSI) Program. This request is needed to support the third 1 O-year lSI interval. The details of the 10 CFR 50.55a request is provided in Attachment 1.

Entergy request NRC Staff review and approval of this proposed RBS Request (RBS-ISI-020) no later than November 30, 2017. The duration of this request will be for the Third 10-Year lSI Interval scheduled to be completed by November 30,2017.

There are no regulatory commitments made in this submittal. If you have any questions or require additional information, please contact Timothy Schenk at 225-381-4177.

This letter contains no new Regulatory Commitments.

TAS/alc

RBG-47789 Page 2 of 2 : Request to use a later Edition and Addenda of the ASME Boiler and Pressure Vessel Code,Section XI, for Inserve Inspection (lSI) Activities at River Bend Station, in Accordance with 10CFRSO.SSa(g)(4)(iv) cc:

U.S. Nuclear Regulatory Commission Region IV 1600 E. Lamar Blvd.

Arlington, TX 76011-4511 Ms. Lisa M. Regner, Project Manager U.S. Nuclear Regulatory Commission MS-8-H4 One White Flint North 11555 Rockville Pike Rockville, MD 20852 NRC Senior Resident Inspector PO Box 1050 St. Francisville, LA 70775 Department of Environmental Quality Office of Environmental Compliance Radiological Emergency Planning and Response Section Ji Young Wiley P.O. Box 4312 Baton Rouge, LA 70821-4312 Public Utility Commission of Texas Attn: PUC Filing Clerk 1701 N. Congress Avenue P. O. Box 13326 Austin, TX 78711-3326 RBF1-17-0114 LAR 2017-07

ENTERGY OPERATIONS, INC.

RIVER BEND STATION - UNIT 1 REQUEST No. RBS-ISI-020 IN ACCORDANCE WITH 10 CFR SO.SSa(g)(4)(iv) FOR INSERVICE INSPECTION ITEMS Pursuant to 10 CFR SO.SSa(g)(4)(iv) and in accordance with the guidance of Regulatory Issue Summary (RIS) 2004-12, "Clarification on Use of Later Editions and Addenda to the ASME OM Code and Section XI," Reference 1, River Bend Station, Unit 1, (RBS) requests NRC approval to utilize the 2007 Edition through the 2008 Addenda of the American Society of Mechanical Engineers (ASME) Code,Section XI, Reference 2, for Examination Category C-G Items as defined below.

1. ASME Code Components Affected Code Class:

References:

Examination Category:

Item Number:

==

Description:==

Unit / Inspection Interval Applicability:

2 ASME Section XI, 2001 Edition through the 2003 Addenda, Table IWC-2S00 "Code of Record", Reference 3 C-G CS.10 Pump Casing Welds River Bend Station, Unit 1 / Third 10-Year Inservice Inspection (lSI)

Interval May 31,2008 - November 30,2017

2. Applicable Code Edition and Addenda

The Code of Record for the current Third 10-Year lSI Interval at RBS is ASME Section XI, 2001 Edition through the 2003 Addenda. This Code of Record is applicable to the Examination Category C-G welds, for which the use of a subsequent ASME Code Edition and Addenda is being requested.

3. Proposed Subsequent Code Edition and Addenda (or Portion)

A. Background In accordance with the 1 O-year update requirements of 10 CFR SO.SSa(g)(4)(ii), ASME Section XI lSI activities at RBS were initially updated for the Third 10-Year lSI Interval to the 2001 Edition through the 2003 Addenda, with an implementation date of May 31,2008.

B. Proposed Use of Subsequent Code Edition and Addenda The subsequent Code edition and addenda proposed for the RBS lSI Program, Examination Category C-G, is ASME Section XI, 2007 Edition through the 2008 Addenda.

In the 2008 Addenda, Examination Category C-G was deleted from the Code.

In the 2001 Edition through the 2003 Addenda of ASME Section XI:

Category C-G requires a surface examination of the pump casing welds in all components in each piping run examined under Examination Category C-F.

ASME Examination Category C-G welds were removed in the ASME Section XI, 2007 Edition through the 2008 Addenda because experience has not identified any failures in pump casing or valve body welds. The requirements for performing these examinations of the pump casing welds resulted in unnecessary radiation exposure for Nondestructive Examination personnel.

For Class 2 welds in pump casings, any degradation of the pump interior will be detected by the mechanic working on the component internals. Through-wall leakage will be detected by the Visual VT-2 examinations during the system pressure tests.

The subsequent Code edition and addenda proposed under this request is the ASME Section XI, 2007 Edition through the 2008 Addenda, for Examination Category C-G. The 2008 Addenda of Section XI has been incorporated into the regulations by reference in (a)(1 )(ii), as published in the Federal Register on June 21,2011 (76 FR 36232), and became effective July 21, 2011. Furthermore, 10 CFR SO.SSa(b) contains no conditions or provisions that pertain to Examination Category C-G items in the 2007 Edition through the 2008 Addenda of ASME Section XI.

4. Related Requirements For the portion of the subsequent Code edition and addenda to be used, no related requirements would need to be implemented since the 2008 Addenda deletes Examination Category C-G from the Code.
5. Duration of Proposed Request The duration of this request will be for the RBS Third 10-Year lSI Interval scheduled to be completed by November 30,2017.

6. Precedents

(1) NRC Safety Evaluation Report (SER) - Nine Mile Point Nuclear Station, Unit Nos. 1 and 2-RE: Request for Approval to Use a Later ASME Code Section XI Edition and Addenda for Examination Categories B-L-1, B-M-1, AND C-G, (TAC NOS. MF1316 AND MF1317),

Dated: March 14, 2014, [ADAMS Accession No. ML14064A339]

(2) NRC Safety Evaluation Report (SER) - Palo Verde Nuclear Generating Station, Units 1,2, and 3 Request for Relief to Use a Later Edition of ASME Code,Section XI, for Examination Categories B-L-1, B-M-1, AND C-G (TAC NOS. ME7BOS, ME7B06. AND ME7B07), Dated: September 18, 2012, [ADAMS Accession ML 122S7A141]

7. References
1. Regulatory Issue Summary (RIS) 2004-12 "Clarification on Use of Later Editions and Addenda to the ASM E OM Code and Section XI"
2. ASME Code Section XI, Rules for Inservice Inspection of Nuclear Power Plant Components, Division 1, 2007 Edition through the 2008 Addenda
3. ASME Code Section XI, Rules for Inservice Inspection of Nuclear Power Plant Components, Division 1, 2001 Edition through the 2003 Addenda