'anuary

6, 1999

Dr. Robert C. Mecredy

Vice President,

Ginna Nuclear Operations

Rochester Gas and Electric Corporation

89 East Avenue

Rochester,

New York 14649

SUBJECT:

NRC INTEGRATED INSPECTION REPORT 50-244/98-12

Dear Dr. Mecredy:

This letter transmits the results of safety inspections conducted by NRC inspectors at the

Ginna Nuclear Power Plant from October 19 through November 29, 1998. At the

conclusion of the inspection, the findings were discussed with Mr. J. Widay and others of

your staff.

During the six weeks covered by this inspection, we noted good operator response to a

partial loss of offsite power and to an inadvertent dilution of the reactor coolant system.

Our review of the Inservice Testing area identified a well designed and implemented

program.

Some minor discrepancies

were identified, but promptly addressed

by your staff.

We noted that seat leak testing conducted on certain containment isolation valves in the

service water system may have been inappropriate, in that the valves were pre-conditioned

prior to leak testing.

We understand that prior to startup from the next refueling outage

you have committed to review the seat leak test procedure and the valve design criteria,

and modify them, as needed, or justify the acceptability of current testing methodology.

Inspector follow-up of your previous commitments to improve long-term service water

system performance, including initiatives to refurbish pumps, modify heat exchangers,

and

develop an improved hydraulic model, identified these items to have been satisfied.

Accordingly, the NRC staff's review of your Generic Letter 89-13 Program is complete.

In accordance with 10 CFR 2.790 of the NRC's "Rules of Practice," a copy of this letter

and its enclosures will be placed in the NRC Public Document Room (PDR).

Sincerely,

Original Signed By:

Lawrence T. Doerflein, Chief

Projects Branch

1

Division of Reactor Projects

990ii90041

990%06

PDR

ADOCK OS000244

8

PDR

f

~

Dr. Robert C. Mecredy

Docket No.: 50-244

License No: DPR-18

Enclosures:

Inspection Report 50-244/98-12

cc w/encl:

P. Wilkens, Senior Vice President, Generation

Central Records (7 copies)

P. Eddy, Electric Division, Department of Public Service, State of New York

C. Donaldson, Esquire, State of New York, Department of Law

N. Reynolds, Esquire

F. William Valentino, President, New York State Energy Research

and Development Authority

J. Spath, Program Director, New York State Energy'Research

and Development Authority

Dr. Robert C. Mecredy

Distribution w/encl:

H. Miller, RA/J. Wiggins, DRA (1)

Region

I Docket Room (with concurrences)

PUBLIC

NRC Resident Inspector

Nuclear Safety Information Center (NSIC)

L. Doerflein, DRP

W. Cook, DRP

R. Junod, DRP

Distribution w/encl (VIAE-MAIL):

G. Shear,

Rl EDO Coordinator

S. Bajwa, NRR

G. Vissing, NRR

M. Campion, ORA

Inspection Program Branch, NRR (IPAS)

R. Correia, NRR

DOCDESK

DOCUMENT NAME: G'iBRANCH1IIGIN9812.INS

To receive a copy of thie document, Indicate In the box: "C

~ Copy without attachment/enclosure

E

Copy with attachment/enclosure

N

No copy

OFFICE

RI/DRP

NAME

PDrysdale

DATE

01/gp/99

RI/DRP

LDoerflein

01/

99

OFFICIAL RECORD COPY