ML17265A337
| ML17265A337 | |
| Person / Time | |
|---|---|
| Site: | Ginna |
| Issue date: | 06/12/1998 |
| From: | Eugene Kelly NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | Mecredy R ROCHESTER GAS & ELECTRIC CORP. |
| Shared Package | |
| ML17265A338 | List: |
| References | |
| 50-244-98-06, 50-244-98-6, GL-89-10, NUDOCS 9806220190 | |
| Download: ML17265A337 (4) | |
See also: IR 05000244/1998006
Text
( 'A.'LKUUKX 4
REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:9806220190
DOC.DATE: 98/06/12
NOTARIZED: NO
DOCKET I
~
~
~
~
~
FACIL:50-244 Robert
Emmet Ginna Nuclear Plant, Unit 1, Rochester
G
05000244
AUTH.NAME
AUTHOR AFFILTATION .
KELLY,E.M.
Region
1 (Post
820201)
RECIP.NAME
'ECIPIENT AFFILIATION
MECREDY,R.C.
Rochester
Gas
E Electric Corp.
SUBJECT:
Forwards insp rept 50-244/98-06
on 980416-0528.No violations
noted.NRC closing review of util program implemented under
DTSTRTBDTTON CODE:
1E01F
COF1ES
RECEIVED:LTR /
ENCL
SIZE: 5+5
TITLE: General
(50 Dkt)-Insp Rept/Notice of Violation
esponse
NOTES:License
Exp date in accordance
with 10CFR2,2.109(9/19/72).
'
05000244
G
RECIPIENT
ID CODE/NAME
PD1-1
INTERNAL: AEOD/SPD/RAB
DEDRO
NRR/DRCH/HHFB
NRR/DRPM/PERB
OE DIR
RGN1
FILE
01
COPIES
LTTR ENCL
1
1
1
1
1
1
1
1
1
1
1
1
1
1
RECIPIENT
.ID CODE/NAME
VISSING,G.
D/
FILE CENT
R/'DRPM
CB
NUDOCS-ABSTRACT
OGC/HDS3
COPIES
LTTR ENCL
1
1
1
1
1
1
1
1
1
1
1
1
TERNAL: LITCO BRYCE,J H
NRC PDR
1,1
1
'1
NOAC
NUDOCS FULLTEXT
1
'
1
1
E Opg~
Qg~ +8 pQ
Oopy
NOTE TO ALL "RZDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LIST
OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL
DESK
tDCD)
ON EXTENSION 415-2083
TOTAL NUMBER OF COPIES
REQUIRED:
LTTR
17
ENCL
17
June 12,
1998
Dr. Robert C. Mecredy
Vice President,
Ginna Nuclear Operations
Rochester Gas and Electric Corporation
89 East Avenue
Rochester, New York 14649
SUBJECT:
Dear Dr. Mecredy:
NRC MOTOR OPERATED VALVEINSPECTION 50-244/98-06
This letter transmits the results of the NRC special in-office inspection conducted from
April 16 through May 28, 1998 regarding the Ginna Nuclear Power Plant.
The inspection
focused on areas important to the public health and safety, and consisted of an
independent evaluation of the motor-operated valve (MOV) program associated with NRC Generic Letter (GL) 89-10, "Safety-Related Motor-Operated Valve Testing and
Surveillance." At the conclusion of the inspection, the preliminary findings were discussed
with you and members of your staff on June 11, 1998.
Based on the review and closure of open items, the NRC is closing its review of your
program implemented under GL 89-10
In accordance with 10 CFR 2.790 of the NRC's "Rules of Practice," a copy of this letter
and the enclosures will be placed in the NRC Public Document Room (PDR) ~
Sincerely,
ORIGINAL SIGNED BY:
Eugene M. Kelly, Chief
Systems Engineering Branch
Division of Reactor Safety
Docket No. 50-244
License No.
Enclosure:
Inspection Report 50-244/98-06
9806220i90 980612
ADQCK 05000244
6
Dr. Robert C. Mecredy
cc w/encl:
R. Smith, Senior Vice President, Customer Operations
Central Records (7 copies)
P. Eddy, Electric Division, Department of Public Service, State of New York
C. Donaldson, Esquire, State of New York, Department of L'aw
N. Reynolds, Esquire
F. William Valentino, President, New York State Energy Research
and Development Authority
J, Spath, Program Director, New York State Energy Research
and Development Authority
Dr. Robert C. Mecredy
Distribution w/encl:
H, Miller, RA/W. Axelson, DRA (1)
Region
I Docket Room (with concurrences)
PUBLIC
NRC Resident Inspector
Nuclear Safety Information Center (NSIC)
J. Wiggins, DRS
L. Nicholson, DRS
E. Kelly, DRS
L. James,
L. Doerflein, DRP
'R. Junod, DRP
DRS File
Distribution w/encl (VIAE-MAIL):
B. McCabe, RI EDO Coordinator
S. Bajwa, NRR
G. Vissing, NRR
M. Campion, ORA
Inspection Program Branch, NRR (IPAS)
D. Screnci, PAO
R. Correia, NRR
F. Talbot, NRR
T. Scarbrough,
A. Belisle, Rll
W. Kropp, Rill
T. Stetka, RIV
DOCDESK
DOCUMENT NAME: G:iSYSTEMSiJAMESiGINNAiGIN9806.INS
To receive a copy of this document. indicate fn the box:
C" ~ Copy without attachment/enclosure
"E" ~ Copy with anachment/enclosure
"N
No copy
OFFICE
NAME
DATE
RI /DRS
LJames
06/08/98
RI/DRP
LDoerflein
06/
/98
RI/DRS
EKell
06/
/98
RWessman
06/q /98
06/
/98
OFFICIAL RECORD CO
Wtr
~ca
c
<1 gt,.~ Q, 7p~~