ML17264B151

From kanterella
Jump to navigation Jump to search
Forwards Insp Rept 50-244/97-13 on 971027-31 & 1105-07 & Notice of Violation.Nrc Unable to Reach Closure Re Baseline GL 89-10 Program
ML17264B151
Person / Time
Site: Ginna 
Issue date: 12/24/1997
From: Wiggins J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Mecredy R
ROCHESTER GAS & ELECTRIC CORP.
Shared Package
ML17264B152 List:
References
50-244-97-13, GL-89-10, NUDOCS 9801050157
Download: ML17264B151 (5)


See also: IR 05000244/1997013

Text

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9801050157

DOC.DATE: 97/12/24

NOTARIZED: NO

DOCKET ¹

PACIL:50-244 Robert

Emmet Ginna Nuclear Plant, Unit 1, Rochester

G

05000244

AUTH.NAME

AUTHOR AFFILIATION

WIGGINS,J.T.

Region

1 (Post

820201)

RECIP . NAME

RECIPIENT AFFILIATION

MECREDY,R.C.

Rochester

Gas

& Electric Corp.

SUBJECT: Forwards insp rept 50-244/97-13

on 971027-31

& 1105-07

&

notice of violation.NRC unable to reach closure re baseline

C

GL 89-10 program.

A

DTSTRTBUTION CODE:

1E01F

COPIES

RECETVED:LTRj ENCL

(

STZE:

3

7

TITLE: General

(50 Dkt)-Insp Rept/Notice of Violation Response

T

NOTES:License

Exp date in accordance

with 10CFR2,2.109(9/19/72)

.

05000244m

RECXPXENT

ID CODE/NAME

PD1-1

PD

INTERNAL: AEOD/SPD/RAB

DEDRO

NRR/DRCH/HHPB

NRR/DRPM/PERB

OE DIR

RGN1

FILE

01

COPIES

LTTR ENCL

1

1

1

1

1

1

1

1

1

1

1

1

1

1

RECIPIENT

ID CODE/NAME

VISSING,G.

TC

PILE CENTE

B

NUDOCS -ABSTRACT

OGC/HDS3

COPIES

LTTR ENCL

1

1

1

1

1

1

1

1

1

1

1

1

R

XTERNAL: LITCO BRYCE,J H

NRC PDR

1

1

1

1

NOAC

NUDOCS FULLTEXT

1

1

1

1

D

F'.OABEO FPOV..

I @Re vzor.-'

N

NOTE TO ALL "RZDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS

OR REDUCE THE NUMBER OF COPZES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL

DESK

(DCD)

ON EXTENSION 415-2083

TOTAL NUMBER OF COPIES

REQUIRED:

LTTR

17

ENCL

17

December

24,

1997

Dr. Robert C. Mecredy

Vice President,

Ginna Nuclear Operations

Rochester Gas and Electric Corporation

89 East Avenue

Rochester,

NY 14649

SUBJECT:

INSPECTION REPORT NO. 50-244/97-13AND NOTICE OF VIOLATION

Dear Mr. Mecredy:

This letter transmits the results of the NRC special inspection conducted on October 27

through November 7 at the Ginna Nuclear Power Station.

The inspection focused on areas

important to the public health and safety, and consisted of an independent evaluation of

motor-operated valve (MOV) program procedures,

calculations, and test results associated

with NRC Generic Letter (GL) 89-10, "Safety-Related Motor-Operated Valve Testing and

Surveillance."

The preliminary findings were discussed

on several instances,

and most

recently on November 18, 1997.

Substantial improvement over the past year was evident. "Self assessment

and

independent reviews were effectively utilized to develop significant enhancements

in MOV

design and testing.

However, the NRC was unable to reach closure regarding the baseline

GL 89-10 program.

While the technical quality of calculations was generally improved,

certain input assumptions were used without adequate validation, resulting in an incorrect

design which under-estimated

the thrust requirements for three MOVs. Design basis

calculations of record (performed by a vendor) had not been finalized under the Ginna

Station Quality Assurance

Plan at the time of this inspection, and had not as such received

formalized RGSE review and approval.

These findings are of concern to the NRC since you

committed in a January 13, 1997 letter to complete the implementation of proposed

enhancements

to the GL 89-10 program in June 1997.

The above findings were characterized

as violations of 10 CFR 50 Appendix B, Criterion III,

"Design Control" and 10 CFR 50 Appendix B, Criterion Vll, "Control of Purchased

Material,

Equipment, and Services."

The violations are cited in the enclosed Notice of Violation

(Notice) and the circumstances

surrounding them are described in detail in the subject

report.

You are required to respond to this letter and should follow the instructions

specified in the enclosed Notice when preparing your response.

In your response,

you

should document the specific actions taken and any additional actions you plan to prevent

recurrence.

Your response

may reference or include previous docketed correspondence,

if

the correspondence

adequately addresses

the required response.

After reviewing your

response to this Notice, including your proposed corrective actions and the results of

future inspections, the NRC willdetermine whether further NRC enforcement action is

necessar

to ensure compliance with NRC regulatory requirements.

y

980i050i57 97i224

PDR

ADOCK 05000244

8

PDR

llllllllllllllllllllllllllllllilllllllll

4

Mr. Robert C. Mecredy

We are also concerned with your use of a programmable database to perform calculations

and provide inputs to safety-related design documents.

We therefore request that you

address the use of the SMARTBOOKdatabase

in this manner along with your response to

the enclosed Notice.

The response directed by this letter and the enclosed Notice are not subject to the

clearance procedures of the Office of Management and Budget as required by the

Paperwork Reduction Act of 1980, Pub. L. No.96-511. We appreciate your cooperation

and would be pleased to discuss our findings and conclusions.

Sincerely,

James T. Wiggins, Director

Division of Reactor Safety

Docket No. 50-244

License No. DPR-18

Enclosure: NRC Inspection Report 50-244/97-13

cc w/encl:

R. Smith, Senior Vice President, Customer Operations

Central Records (7 copies)

P. Eddy, Director, Electric Division, Department of Public Service, State

of New York

State of New York, Department of Law

N. Reynolds, Esquire

F. William Valentino, President, New York State Energy Research

and Development Authority

J. Spath, Program Director, New York State Energy Research

and Development Authority

Mr. Robert C. Mecredy

Distribution w/encl:

H. Miller, RA/W. Axelson, DRA (1)

D. Screnci, PAO

Region

I Docket Room (with concurrences)

PUBLIC

NRC Resident Inspector

Nuclear Safety Information Center (NSIC)

L. Doerflein, DRP

R. Junod, DRP

DRS File

Distribution w/encl (VIAE-MAIL):

W. Dean, OEDO

K. Kennedy,

RI EDO Coordinator

S. Bajwa, NRR

G. Vissing, NRR

M. Campion, ORA

Inspection Program Branch, NRR (IPAS)

R. Correia, NRR

F. Talbot, NRR

DOCDESK

P. Frederickson,

Rll

W. Kropp, Rill

A1. Stetka, RIV

T. Scarbrough,

NRR

pg!@a~ T Q

DOCUMENTNAME: a:GIN97'l3.INS~I(4

To receh!e a copy of this document. Indicate In the bosn

C

~ Copy without attachment/

closure

E

~ Copy with anachment/enclosure

"N"

cd y

OFFICE

NAME

DATE

RI:DRS

NRR:MEB

I:DRP

KKolaczyk )()/ I

DTeracf

1 2/tj797

1 2

97

L

e

lein

1

7

OFFICIAL

ECORD

OPY

RI:DRS

EKell

1

97

RI:

RS

JWiggin