CATEGORY 2
REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION
NBR 9709160074
DOC.DATE: 97/09/09
NOTARIZED: NO
DOCKET
FACIL:50-244 Robert
Emmet Ginna Nuclear Plant, Unit 1, Rochester
G
05000244
AUTH.NAME
AUTHOR AFFILIATION
DOERFLEIN,L.T.
Region
1 (Post
820201)
RECIP.NAME
RECIPIENT AFFILIATION
MECREDY,R.C.
Rochester
Gas
& Electric Corp.
SUBJECT:
Forwards insp rept 50-244/97-06
on 970630-0803.No violations
noted. Discrepancy
noted
between meteorological
tower base
instrumentation
a control room instrumentation
data.
DISTRIBUTION CODE:
IEOIR
COPIES
RECEIVED:LTR
(
ENCL L
SIZE:
TITLE: General
(50 Dkt)-Insp Rept/Notice of Violation Response
NOTES:License
Exp date in accordance
with 10CFR2,2.109(9/19/72).
T
05000244
8
RECIPIENT
ID CODE/NAME
PD1-1
INTERNAL: AEOD/SPD/RAB
DEDRO
NRR/DISP/PIPB
NRR/DRPM/PECB
NUDOCS-ABSTRACT
OGC/HDS3
ERNAL: LITCO BRYCEEJ
H
NRC
/ms'F(D
COPIES
LTTR ENCL
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
RECIPIENT
ID CODE/NAME
VISSING,G.
eBp"2%
FILE CENTER
DRCN/HH B
NRR/DRPM/PERB
OE DIR
RGN1
FILE
01
NOAC
NUDOCS FULLTEXT
COPIES
LTTR ENCL
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
D
0
'g(g,gpo jgQM
gaGFto>>~
M
E
N
NOTE TO ALL "RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRISUTION LISTS
OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL
DESK
(DCD)
ON EXTENSION 415-2083
I'P
TOTAL NUMBER OF COPIES
REQUIRED:
LTTR
P1
ENCL
September
9,
1997
Dr. Robert C. Mecredy
Vice President,
Ginna Nuclear Operations
Rochester Gas and Electric Corporation
89 East Avenue
Rochester,
New York 14649
SUBJECT:
NRC INTEGRATED INSPECTION REPORT 50-244/97-06
Dear Dr. Mecredy:
This letter transmits the results of safety inspections conducted
by NRC inspectors at the
Ginna Nuclear Power Plant from June 30, 1997 through August 3, 1997. At the
conclusion of the inspection, the findings were discussed
with Mr. J. Widay and others of
your staff. The inspection report also includes a summary of the predecisional
enforcement conference
held in the NRC Region
I Office on August 5, 1997, to discuss the
vehicle barrier system issues identified in Inspection Report 50-244/97-08.
During the five week period covered by this inspection period, we noted safe plant
operation.
Several good activities in the operations
and maintenance
areas were noted,
including your efforts toward resolving the auxiliary feedwater pump recirculation valve
unreliability, diagnosing anomalous service water pump performance,
and replacing the
spent fuel pool weir gate bladder.
During our review of your radiological environmental monitoring program, we noted a
discrepancy between the meteorological tower base instrumentation
and the control room
instrumentation data.
We are concerned that the data discrepancy could impact
emergency response
activities.
We request that you review this matter and provide us the
results of your review in writing, including any corrective actions, within 60 days from the
receipt this letter.
In accordance
with 10 CFR 2.790 of the NRC's "Rules of Practice," a copy of this letter
and its enclosures
will be placed in the NRC Public Document Room (PDR).
Sincerely,
Original Signed
by:
1 I,gpss'7
Lawrence T. Doerflein, Chief
Projects Branch
1
Division of Reactor Projects
Docket No.: 50-244
License No: DPR-18
9709160074
970909
ADOCK 05000244
8
llllllllIIllllll!IIIIIIIII)IIIlilllllllyp,
n ~<</~~>
OFFICIAL RECORD
COPY
IE 01
Robert C. Mecredy
Enclosure:
Inspection Report 50-244/97-06
cc w/encl:
R. Smith, Senior Vice President,
Customer Operations
Central Records (7 copies)
P. Eddy, Director, Electric Division, Department of Public Service, State
of New York
State of New York, Department of Law
N. Reynolds,
Esquire
F. William Valentino, President, New York State Energy Research
and Development Authority
J. Spath, Program Director, New York State Energy Research
and Development Authority
Robert C. Mecredy
Distribution w/encl:
H. Miller, RA
W. Axelson, DRA
Region
I Docket Room (with concurrences)
PUBLIC
NRC Resident Inspector
Nuclear Safety Information Center (NSIC)
L. Doerflein, DRP
T. Moslak, DRP
R. Junod,
Distribution w/encl (VIAE-MAIL):
Rl EDO Coordinator
A. Dromerick, NRR
G. Vissing, NRR
M. Campion, ORA
Inspection Program Branch, NRR (IPAS)
R. Correia, NRR
F. Talbot, NRR
.DOCDESK
DOCUMENT NAME: A:IIIR97-06.GIN
To receive a copy of thts document, Indicate In the box:
C
~ Copy without ettschment/enclosure
E
~ Copy with ettechment/enclosure
N
~ No copy
OFFICE
RI/DRP
NAME
PDrysdale
DATE
09/
/97
RI/DRP
LDoerflein
09/
/97
A
R
RD COPY