PRIORITY 1 (ACCELERATED RZDS PROCESSING)

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9509080079 DOC.DATE: 95/08/31 NOTARIZED: YES DOCKET FACIL:50-244 Robert Emmet Ginna Nuclear Plant, Unit 1, Rochester G

05000244 P

AUTH.NAME AUTHOR AFFILIATION MECREDY,R.C.

Rochester Gas

& Electric Corp.

RECIP.NAME RECIPIENT AFFXLXATION JOHNSON,A.R.

SUBJECT:

Forwards application for amends to license DPR-18,proposing TS to implement WCAP-10271,its assoc suppl 6 other re changes w/respect to RTS 6 ESFAS.

0 DISTRIBUTION CODE:

AOOID COPIES RECEIVED:LTR Q ENCL +

SIZE: 3 +l2, TITLE: OR Submittal General Distribution NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72).

05000244 I RECXPIENT ID CODE/NAME PD1-1 LA JO A

=COPIES RECIPIENT LTTR ENCL XD CODE/NAME 1

1 PD1-1 PD 1

1 COPIES LTTR ENCL 1

1 INTERNAL FILE C 01 DRCH/HICB-NRR/DSSA/SRXB OGC/HDS3 EXTERNAL: NOAC 1

1 1

1 1

.1 1

0 1

1 NRR/DE/EMCB NRR/DSSA/SPLB NUDOCS-ABSTRACT NRC PDR 1

1 1

1 1

1 1

1 0

C N

NOTE TO ALL "RZDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE!

CONTACT THE DOCUMENT CONTROL

DESK, ROOM OWFN 5D8 (415-2083)

TO ELIMINATE YOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEEDI TOTAL NUMBER OF COPIES REQUIRED:

LTTR 12 ENCL 11

r, q 5

L

Aen ROCHESTER GASANDElECTRIC CORPORATION ~ 89 EASTAYENUE, ROCHESTER, MY ld649-0001 AREA CODE7I6 5'-2700 ROBERT C. MECREDY Vice President Hvdeoroperotions August 31, 1995 U.S. Nuclear Regulatory Commission Document Control Desk Attn:

Allen R. Johnson Project Directorate I-3 Washington, D.C. 20555

Subject:

Changes to Technical Specification Instrumentation Requirements Conversion to Improved Technical Specifications Rochester Gas 2 Electric Corporation R.E. Ginna Nuclear Power Plant Docket No. 50-244

Dear Mr. Johnson,

By Reference (a), RGB'roposed to convert the current Ginna Station Technical Specifications to the Improved Standard Technical Specifications (i.e., NUEEG-1431).

Included within this conversion were numerous changes to the current requirements for the Reactor Trip System (RTS) and Engineered Safety Features Actuation System (ESFAS).

Several ofthese changes were based on Reference (b), which ifapproved, would allow up to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> to place inoperable RTS and ESFAS channels in the tripped condition and allow the bypass of an inoperable channel for up to 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

Based on conversations with NRC staff RGEcE has agreed to defer these changes until after the conversion process since WCAP-14333 has not yet received staff review and approval. In place of the changes justified by WCAP-14333, RG&E proposes to implement those documented in References (c), (d), and (e) which have received NRC staff review and generic approval.

The purpose ofthis submittal is to provide the necessary justification to implement the changes to the RTS and ESFAS surveillance requirements and required actions as documented in WCAP-10271 and its supplements.

In order to support NRC review ofthis change, this submittal is organized as follows:

The implementation of WCAP-10271 and other related changes is documented in this.

submittal as a separate license amendment request (LAR)with respect to the current Ginna Station Technical Specifications.

Therefore, the required plant specific justification ofthis implementation and significant hazards consideration are provided in this submittal.

~,

sst50tst08007tst sst5083i PDR ADOCK 05000244 PDR

~ 1

~ ~

P V

V b.

The implementation ofWCAP-10271 and other related changes and the removal ofWCAP-14333 with respect to Reference (a) is being provided for the marked up Ginna Station Technical Specifications only (i.e., Attachment A and B to Reference (a) has been revised to show the resulting differences).

The necessary changes to the NUREG-1431 markups (Attachment D to Reference (a)) and the proposed Improved Technical Specifications for Ginna Station (Attachment C to Reference (a)) willbe provided at a later date.

Based on the above, the review ofthis submittal should be coordinated with the overall NRC review ofthe May 26, 1995 submittal since they are interrelated.

Very y yours, Robert C. Mecredy MDF5749 Attachments References (a)

Letter from R.C. Mecredy, RGAE, to A.R. Johnson, NRC,

Subject:

Application for Amendment to Facility Operating License, Conversion to Improved Technical Specifications, dated May 26, 1995.

(b)

WCAP-14333, Probabilistic Risk Analysis of the RPS and ESFAS Test Times and Completion Times, May 1995.

(c)

WCAP-10271-P-A, Evaluation ofSurveillance Frequencies and Out ofService Timesfor the Reactor Protection Instnanentali on System, May 1986.

(d)

WCAP-10271-P-A, Supplement 1, Evaluation ofSurveillance Frequencies and Out of Service Timesfor the Reactor Protection Instrumentation System, May 1986.

(e)

WCAP-10271-P-A, Supplement 2, Revision 1, Evaluation ofSurveillance Isrequencies and Out ofService TiInesfor th'e Engineered Safety Features Actuation System, June 1990.

U.S. Nuclear Regulatory Commission Mr. Allen R. Johnson (Mail Stop 14B2)

PWR Project Directorate I-1 Washington, D.C. 20555 U.S. Nuclear Regulatory Commission Mr. Carl Schulten Technical Specifications Branch (Mail Stop 011E22)

Washington, D.C. 20555 U.S. Nuclear Regulatory Commission Region I 475 Allendale Road King ofPrussia, PA 19406 Ginna Senior Resident Inspector Mr. Jim Andrachek Westinghouse Electric Company Energy Center East 4-1 4350 Northern Pike Monroeville, PA 15146-2886 Mr. Donald Hoffman EXCEL Services Corporation 11921 Rockville Pike Suite 100 Rockville, MD 20852