SUBJECT:
Rev 5 to Att-17.0, "Attachment SD-1." W/950203 ltr.
DISTRIBUTION CODE A045D COPIES RECEIVED:LTR J ENCL SIZE:
TITLE: OR Submittal:
Emergency Preparedness,Pla s, Implement'g Procedures, C
pi 0
NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72).
05000244 R
RECIPIENT ID CODE/NAME PD1-3 PD INTERNAL~ICE CENTER P1
~NUDOCS A'BSTRACT EXTERNAL: NOAC COPIES LTTR ENCL 1
1 1
1 1
1 1
1 RECIPIENT ID CODE/NAME JOHNSON,A NRR/DRSS/PEPB NRC PDR COPIES LTTR ENCL 1
1 1
1 1
1 D
0 U
N NOTE TO ALL"RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE iVASTE!CONTACI'THE DOCUMENTCONTROL DESK, ROOM PI -37 (EXT. 504-2083 ) TO E Llih!INATE YOUR NAME FRO~I DISTRIBUTIONLISTS FOR DOCI;MENTS YOU DON"I'LED!
TOTAL NUMBER OF COPIES REQUIRED:
LTTR 7
ENCL 7
t
<<P,/.<<III<<I
<<<<<<<<<<<<&'J<<<<<<<<<<<<<<<<<<<<I ROCHESTER GAS ANDELECTRIC CORPORATION o 89 EAST AVENUE, ROCHESTER, N. Y.
14649-0001 TELEPHONE AREA COOE 71B 546-2700 February 3, 1995 Mr. Allen Johnson Project Directorate I-3 U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C.
20555
Subject:
Emergency Operating Procedures R.E. Ginna Nuclear Power Plant Docket No. 50-244
Dear Mr. Johnson:
As requested, enclosed are Ginna Station Emergency Operating Procedures.
Very Truly Yours, a.d oseph A. Widay JAW/jdw xc:
Mr. Lee Bettenhausen, USNRC, Region 1
Resident Inspector, Ginna Station RG&E Nuclear Safety & Licensing y/,on2S 9502130285 950203 PDR ADOCK 05000244 F
Page 2
Enclosures:
ATT-17.0 Revision 5
EOP:
ATT-17.0 1' ILE:
ATTACHMENT SD-1 REV:
4 PAGE 1/of 2
Su rintendent Date 7
Perf m the following local actions to complete normal secondary syste shutdown:
ose reheater 4th pass temperature control valves:
V-2432 (SW corner 1A MSR) o V-2433 (SW corner 1B MSR) o V-2434 (SW corner 2A MSR) o
Close r heater steam chain valves:
o V-3 50 (SW of 1B MSR) o V-35 1
(SW of 1b MSR) o V-355 (NW of 1A MSR) o V-3553 (NW of 1A MSR) 0 Open Reheater steamline vents middle floor):
o V-8500 o
V-8501 o
V-8502 o
V-8504 o
V-8505 SW corner of condenser, Close flange heting solation valves:
o MOV-3601A (TB i die Lvl West of TURB L.O. Reservoir) o MOV-3602A NOTE:
IF either S/G p essure i LESS THAN condensate header
- pressure, THEN manual iso ation of the MFW regulating and bypass valve should be c sidered before aligning for cooldown re irculation.
Open the ollowing valves to align for condensate feed system oldown RECIRC:
o V
982B (at N5 heater ou et header) o
-3983B (at N5 heater out et header) o V-4363 (at N5 heater outle header) o V-4365 (by MFW regulating ives)
V-4361 (southwest corner of condenser, middle floor) o V-3976A MFP A discharge valv bypass valve o
V-3977A MFP B discharge valve bypass valve Secure all 5 secondary chemical add tion pumps on TURB BLDG middle floor by N5 heaters.
o Secure all 3 ammonia
- pumps, TURB BLDG basement by MCC A.
+1 Q
I I
A t l t
EOP:
ATT-17.0 ATTACHMENT SD-1 REV:
4 PAGE 2 of 2
o Isolate SW from the following coolers:
o MFW Pump Oil Coolers (MFW pump room) o V-4703 o
V-4704 o
Exciter Air Cooler:
o V-4679 (chain valve next to condensate transfer pump) o Bus Duct Air Cooler (TURB BLDG basement East of bus duct cooler) o V-4674 o
V-4674C (mini bypass around V-4674) o Throttle SW as necessary from following coolers:
o Generator Seal Oil Unit Coolers (H2 side and air side):
o V-4674A (mini bypass disch valve inside seal oil enclosure Bldg.
NW corner) o V-4677A (mini bypass disch valve inside seal oil enclosure Bldg.
NW corner) o Main Lube Oil Coolers (SW corner of Turb Oil Reservoir) o V-4691 o
V-4692 o
WHEN the turbine shaft stops, THEN notify Control Room.
Control Room personnel will determine if adequate power available to start turning gear.
o Transfer house heating steam to house heating boiler if necessary (refer to T-35H, NUCLEAR HOUSE HEATING STEAM TO BOILER STEAM SUPPLY CHANGE).
o Perform T-14G, STEAM GENERATOR BLOWDOWN HEAT RECOVERY SYSTEM SHUTDOWN.
o Restore MAKEUP to CSTs as directed by Control Room.
- ~