Rev 5 to Att-17.0, "Attachment SD-1." W/950203 ltr.

DISTRIBUTION CODE A045D COPIES RECEIVED:LTR J ENCL SIZE:

TITLE: OR Submittal:

Emergency Preparedness,Pla s, Implement'g Procedures, C

pi 0

NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72).

05000244 R

RECIPIENT ID CODE/NAME PD1-3 PD INTERNAL~ICE CENTER P1

~NUDOCS A'BSTRACT EXTERNAL: NOAC COPIES LTTR ENCL 1

1 1

1 1

1 1

1 RECIPIENT ID CODE/NAME JOHNSON,A NRR/DRSS/PEPB NRC PDR COPIES LTTR ENCL 1

1 1

1 1

1 D

0 U

N NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE iVASTE!CONTACI'THE DOCUMENTCONTROL DESK, ROOM PI -37 (EXT. 504-2083 ) TO E Llih!INATE YOUR NAME FRO~I DISTRIBUTIONLISTS FOR DOCI;MENTS YOU DON"I'LED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 7

ENCL 7

t

<<P,/.<<III<<I

<<<<<<<<<<<<&'J<<<<<<<<<<<<<<<<<<<<I ROCHESTER GAS ANDELECTRIC CORPORATION o 89 EAST AVENUE, ROCHESTER, N. Y.

14649-0001 TELEPHONE AREA COOE 71B 546-2700 February 3, 1995 Mr. Allen Johnson Project Directorate I-3 U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C.

20555

Subject:

Emergency Operating Procedures R.E. Ginna Nuclear Power Plant Docket No. 50-244

Dear Mr. Johnson:

As requested, enclosed are Ginna Station Emergency Operating Procedures.

Very Truly Yours, a.d oseph A. Widay JAW/jdw xc:

Mr. Lee Bettenhausen, USNRC, Region 1

Resident Inspector, Ginna Station RG&E Nuclear Safety & Licensing y/,on2S 9502130285 950203 PDR ADOCK 05000244 F

PDR

Page 2

Enclosures:

ATT-17.0 Revision 5

EOP:

ATT-17.0 1' ILE:

ATTACHMENT SD-1 REV:

4 PAGE 1/of 2

Su rintendent Date 7

Perf m the following local actions to complete normal secondary syste shutdown:

ose reheater 4th pass temperature control valves:

V-2432 (SW corner 1A MSR) o V-2433 (SW corner 1B MSR) o V-2434 (SW corner 2A MSR) o

-2435 (SW corner 2B MSR)

Close r heater steam chain valves:

o V-3 50 (SW of 1B MSR) o V-35 1

(SW of 1b MSR) o V-355 (NW of 1A MSR) o V-3553 (NW of 1A MSR) 0 Open Reheater steamline vents middle floor):

o V-8500 o

V-8501 o

V-8502 o

V-8504 o

V-8505 SW corner of condenser, Close flange heting solation valves:

o MOV-3601A (TB i die Lvl West of TURB L.O. Reservoir) o MOV-3602A NOTE:

IF either S/G p essure i LESS THAN condensate header

pressure, THEN manual iso ation of the MFW regulating and bypass valve should be c sidered before aligning for cooldown re irculation.

Open the ollowing valves to align for condensate feed system oldown RECIRC:

o V

982B (at N5 heater ou et header) o

-3983B (at N5 heater out et header) o V-4363 (at N5 heater outle header) o V-4365 (by MFW regulating ives)

V-4361 (southwest corner of condenser, middle floor) o V-3976A MFP A discharge valv bypass valve o

V-3977A MFP B discharge valve bypass valve Secure all 5 secondary chemical add tion pumps on TURB BLDG middle floor by N5 heaters.

o Secure all 3 ammonia

pumps, TURB BLDG basement by MCC A.

+1 Q

I I

A t l t

EOP:

ATT-17.0 ATTACHMENT SD-1 REV:

4 PAGE 2 of 2

o Isolate SW from the following coolers:

o MFW Pump Oil Coolers (MFW pump room) o V-4703 o

V-4704 o

Exciter Air Cooler:

o V-4679 (chain valve next to condensate transfer pump) o Bus Duct Air Cooler (TURB BLDG basement East of bus duct cooler) o V-4674 o

V-4674C (mini bypass around V-4674) o Throttle SW as necessary from following coolers:

o Generator Seal Oil Unit Coolers (H2 side and air side):

o V-4674A (mini bypass disch valve inside seal oil enclosure Bldg.

NW corner) o V-4677A (mini bypass disch valve inside seal oil enclosure Bldg.

NW corner) o Main Lube Oil Coolers (SW corner of Turb Oil Reservoir) o V-4691 o

V-4692 o

WHEN the turbine shaft stops, THEN notify Control Room.

Control Room personnel will determine if adequate power available to start turning gear.

o Transfer house heating steam to house heating boiler if necessary (refer to T-35H, NUCLEAR HOUSE HEATING STEAM TO BOILER STEAM SUPPLY CHANGE).

o Perform T-14G, STEAM GENERATOR BLOWDOWN HEAT RECOVERY SYSTEM SHUTDOWN.

o Restore MAKEUP to CSTs as directed by Control Room.

- ~