PRIORIT'Y 2

REGULATOR'S~i8@5184AMSREIHMHITION SYSTEM (RIDS)

ACCESSION NBR:9501180176

DOC.DATE: 95/01/10

NOTARIZED: NO

FACIL:50-244 Robert

Emmet Ginna Nuclear Plant, Unit 1, Rochester

AUTH.NAME

AUTHOR AFFILIATION

LINVILLE,J.C.

Region

1 (Post

820201)

RECIP.NAME

RECIPIENT AFFILIATION

MECREDY,R.C.

Rochester

Gas

a Electric Corp.

DOCKET

G"

05000244

SUBJECT: Forwards insp rept 50-244/94-27

on 941122-1231

& notice

violation.

DISTRIBUTION CODE:

IE01D

COPIES

RECEIVED:LTR

ENCL

SIZE:

TITLE: General

(50 Dkt)-Insp Rept/Notice of Violation Response

NOTES:License

Exp date in accordance

with 10CFR2,2.109(9/19/72).

of

P

I

05000244

C

RECIPIENT

ID CODE/NAME

PD1-3

PD

INTERNAL: AEOD/DEIB

AEOD/SPD/RRAB

DEDRO

NRR/DORS/OEAB

NRR/PMAS/IRCB-E

OE DIR

RGN1

FILE

01

ERNAL: LITCO BRYCE,J

H

NRC

PDR

COPIES

LTTR ENCL

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

RECIPIENT

ID CODE/NAME

JOHNSON,A

AEOD/SPD/RAB

AEOD~

LE CENTER

02

NRR/DRCH HHFB

NUDOCS-ABSTRACT

OGC/HDS3

NOAC

COPIES

LTTR ENCL

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

R

D

U

N

NOTE TO ALL"RIDS" RECIPIENTS:,

PLEASE HELP US TO REDUCE OIASTE! CONTACTTHE DOCL'MENTCONTROL

DESK, ROOihI Pl-37 (EXT, 504-20S3

) TO ELIMIYATEYOUR NAME FROiI

DISTRIBUTION LISTS FOR

DOC!.:CLIENTS

YOU DOi "I NEED!

TOTAL NUMBER OF COPIES

REQUIRED:

LTTR

18

ENCL

18

'

January

10,

1995

Dr. Robert

C. Necredy

Vice President,

Ginna Nuclear Operations

Rochester

Gas

and Electric Corporation

89 East

Avenue

Rochester,

New York 14649

SUBJECT:

NOTICE OF VIOLATION 50-244/94-27

Dear Dr. Necredy:

This letter transmits the November

22 to December

31,

1994 inspection findings

of messrs.

T. Noslak and

E. Knutson at the R.

E. Ginna Nuclear Power Plant.

At

the

end of the inspection,

the findings were discussed

with Nr. J.

Miday and

other

members of your staff.

The inspection

was

focused

on areas

relevant to public health

and safety

and

examined the control of operations,

maintenance,

engineering,

and plant support

activities

conducted

during this

period.

Based

on

the

results

of this

inspection,

one

of

your

activities

appears

to

be

in violation of

NRC

requirements,

as

specified

in the

enclosed

Notice of Violation (Notice).

Although the degradation

that occurred to the C-service

water

pump discharge

expansion

joint did

not directly affect

system

operability,

the

lack of

acceptance criteria in the installation procedure is of concern

because it had

the potential for more serious

consequences.

You are required to respond to this letter

and should follow the instructions

specified in the enclosed Notice when preparing your response.

In your response,

you should

document the specific actions

taken

and

any additional

actions

you

plan to prevent

recurrence.

After reviewing your response

to this Notice,

including your proposed corrective actions and the results of future inspections,

the

NRC will determine

whether further

NRC enforcement

action is necessary

to

ensure

compliance with NRC regulatory requirements.

. In accordance with 10 CFR 2.790 of the NRC's "Rules of Practice,"

a copy of this

letter and its enclosure will be placed in the

NRC Public Document

Room.

The response

directed by this letter and the enclosed Notice are not subject to

the clearance

procedures

of the Office of Management

and Budget

as required

by

the Paperwork Reduction Act of 1980, Public Law No. 96.511.

Your cooperation with us in this matter is appreciated.

Sincerely,

'riginal

Signed

By:

James

C. Linville, Chief

Projects

Branch

3

Division of Reactor Projects

9501180i7b 950ii0

PDR

ADOCK 05000244

8

, PDR

IEOl

Dr. Robert

C.

Necr edy

Docket No. 50-244

Enclosures:

1.

=

Notice of Violation

2.

NRC Region I Inspection

Report 50-244/94-27

cc w/encls:

R. Smith, Senior Vice President,

Customer Operations

Central

Records

(5 copies)

Director, Energy and 'Water Division

State of New York, Department of Law

N. Reynolds,

Esquire

PUBLIC

Nucl ear Safety Informati on Center

(NSIC)

D. Screnci,

PAO (2 copi es)

NRC Resident

Inspector

State of New York, SLO Designee

Dr. Robert

C. Necredy

3

bcc w/encls:

Region I Docket

Room (with concurrences)

W. Lazarus,

DRP

J. Stewart,

DRP

N. Oprendek,

DRP

bcc w/encls

(VIA E-NAIL):

A. Johnson,

PN,

NRR

W. Dean,

OEDO

W. Butler,

NRR

N. Campion,

ORA

N. Shannon,

ILPB

DOCUMENT NANE:

A:GIN9427.NEO

To receive e copy of thl~ document, indicate In the born "C

~ Copy without attachment/encjosure

"E

~ Copy with attachment/enclosure

N

~ No copy

OFFICE

RI/DRP

RI/DRP

RI/DRP

RI/DRP

NAME

DATE

Knutson/meo

Moslak

Lazar

Linv ll

OFFICIAL RECORD

COPY